Section II Specifications (Cont.)

RECEIVER

 

Sensitivity

SSB: 0.25 μV for 10dB (S+N)/N at greater

 

than 1/2-watt of audio output.

 

AM: 0.5μV for 10 dB (S+N)/ at greater

 

than 1/2-watt of audio output.

Selectivity

AM: 6dB @ 3 KHz, 50 dB @ 9 KHz.

 

SSB: 6 dB @ 1.1 KHz, 60 dB @ 2.3 KHz.

Image Rejection

More than 65 dB.

IF Frequency

AM: 7.8 MHz 1st IF, 455 KHz 2nd IF.

 

SSB: 7.8 MHz.

Adjacent-Channel Rejection

60 dB AM & 70 dB SSB.

AM and SSB RF Gain Control

40 dB adjustable for optimum signal

 

reception.

Automatic Gain Control (AGC)

Less than 10 dB change in audio output

 

for inputs from 10 to 100,000 microvolts.

Squelch

Adjustable; threshold less than 0.25 μV.

ANL

Switchable.

Noise Blanker

RF type, effective on AM and SSB.

Voice Lock Range

±1.5 KHz.

Audio Output Power

4 watts into 8 ohms.

Frequency Response

300 to 2500 Hz.

Built-in Speaker

8 ohms, round.

External Speaker (Not Supplied)

8 ohms; disables internal speaker

 

when connected.

CLOCK/COUNTER

 

Clock

24 hr. time.

Counter

Displays transmit and receive frequency.

WEATHER (WX) RECEIVER

 

Type

Single Conversion, Superhet 455Hz IF.

Modulation

FM; ± 5 KHz Deviation.

Sensitivity

Less than 1μV for 12dB Sinad.

Frequency Range

162.400 to 162.550 MHz.

Channels

7; 25KHz Spacing.

Frequency Control

Crystal.

WX Emergency Warning

Phase Lock Loop; 1050Hz.

Audio Output Power

4 watts.

(SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE)

4

Image 6
Contents Solid State Citizens Band SSB/AM TWO-WAY Radio Base Station Cobra What Is Weather Radio? NWR Frequencies and Transmission CharacteristicsCB Story Section I Introduction Frequency RangeChannel MHz Section II Specifications GeneralTransmitter Receiver CLOCK/COUNTERWeather WX Receiver Location Section III InstallationMobile OPERATION/EMERGENCY Power Operation Base Station AntennaControls and Indicators Control FunctionsSection IV Operation Section IV Operation Indicator Functions ANTOperating Procedure to Receive Operating Procedure to TransmitOperating Procedure to Receive Weather Band Frequency COUNTER/LCD Digital Clock To SET TimeFREQ. CTR./CLOCK Receiving SSB Signals Receiving SSB Signals Section V Maintenance and Adjustment FCC WarningSection VI Appendix CodeCode Meaning FEW Rules That should be Obeyed HOW Your CB can Serve YOUUSE Channel 9 for Emergency Messages only Permitted Example MessageAlternate Microphones and Installation Wire MIC CableSection VI Appendix Section VI Appendix If You Need Service If You Think You Need Service, CallHours a day, 7 days a week Warranty Cobra CB Radio Accessories Cobra