Cooper Lighting IMI-694 specifications Sheet 1, Fixture Orientation Guideline

Page 1

INSTALLATION INSTRUCTIONS

IMPORTANT : READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN FOR FUTURE REFERENCE

EPL Envoy

Parking Luminaire

Sheet 1 of 5

8/20/08IMI-694

GENERAL: Upon receipt of luminaire thoroughly inspect for any freight damage, which should be brought to the attention of the delivery carrier. Compare the catalog description listed on the packing slip with the luminaire label on the housing to assure you have received the correct merchandise.

SAFETY: This luminaire must be wired in accordance with the national electrical code and applicable codes and ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure. All work should be done by a qualified electrician.

WARNING: Make certain power is OFF before starting installation or attempting any maintenance.

WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing.

WARNING: Risk of Burn. Disconnect power and allow luminaire to cool before changing lamp or handling luminaire.

WARNING: This luminaire is for use with downlight applications only.

WARNING: RISK OF FIRE! DO NOT mount on or near combustible materials.

FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR DEATH

NOTE : Use minimum 90°C supply wire rating for connections in J-box.

Fixture Orientation Guideline:

Proper orientation of luminaire may vary based upon design requirements specified per given application. Labels are supplied on top of fixture and mounting plate for reference to proper fixture alignment. Align quick mount plate in correct direction by referencing number of fixtures required (double or single row luminaire installation) to direction of arrows. Direction of arrow(s) should be in line with direction of traffic.

LUMINAIRE INSTALLATION:

1.Install quick mount plate on a 4” junction box as shown in (Figure 1). Note the required position of plate to ensure correct light beam orientation from fixture. See guidelines above or labels on top of fixture housing and mounting plate if applicable.

2.Secure hanging hook into the rear hooks of quick mount plate (Figure 2 & 3).

3.Make wiring connection while luminaire is being suspended from hanging hook.

4.Push excess wires and connectors up into the junction box through center access hole.

Figure 1

J-BOX

CENTER ACCESS

QUICK MOUNT

HOLE

PLATE

 

#8-32 SCREW

Figure 2

J-BOX

QUICK MOUNT

PLATE

FRONT HOOKS

REAR HOOKS

LUMINAIRE

HANGING HOOK

Figure 3

J-BOX

HANGING

HOOK

LIFT UP

THEN PUSH

 

LUMINAIRE

 

BACK

LUMINAIRE

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.

NOTE: Specifications and dimensions subject to change without notice.

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH080771

Image 1
Contents Sheet 1 Luminaire InstallationFixture Orientation Guideline Removal of Luminaire Sheet 2Tamper-resistant option Figure Pull luminaire forward FigureSheet 3 Lamp InstallationSheet 4 Sheet 5 THRU-BRANCH Wiring Installation

IMI-694 specifications

Cooper Lighting's IMI-694 is a sophisticated and versatile fixture designed to meet the lighting demands of various environments while offering exceptional performance and energy efficiency. This innovative luminaire is tailored for commercial and industrial applications, ensuring optimal functionality combined with advanced technology.

One of the standout features of the IMI-694 is its exceptional luminance output and uniform light distribution. Equipped with high-efficiency LED sources, it provides bright, consistent illumination that enhances visibility in workspaces, retail environments, and public areas. The fixture’s design minimizes shadows and glare, creating a comfortable visual experience for occupants.

The IMI-694 boasts a durable construction, featuring a robust housing made from high-quality materials that resist wear and corrosion. This rugged design makes it ideal for harsh environments, including manufacturing facilities, warehouses, and outdoor applications. Additionally, the fixture is available in various color temperatures, allowing users to select the ideal ambiance for their specific needs, whether that is a cooler light for increased productivity or a warmer tone for a more relaxed atmosphere.

Another significant advantage of the IMI-694 is its compatibility with advanced lighting control technologies. The fixture can be easily integrated with dimmers, occupancy sensors, and daylight harvesting systems, which contribute to substantial energy savings while providing tailored lighting solutions. This level of integration is especially beneficial for facilities aiming to enhance sustainability and reduce operational costs.

Maintenance is also simplified with the IMI-694, thanks to its long lifespan and easy-access features. The LED technology reduces the frequency of replacements, making it a cost-effective choice for long-term projects. Furthermore, the fixture is designed to offer easy installation, with versatile mounting options that accommodate various ceiling heights and configurations.

In summary, Cooper Lighting's IMI-694 combines advanced LED technology, durability, and flexibility, making it an excellent choice for a wide array of applications. Its energy-efficient performance and compatibility with modern lighting controls position it as a suitable solution for those looking to improve their lighting systems while being mindful of budget and environmental impact. With the IMI-694, users can expect exceptional reliability, enhanced productivity, and an overall improved lighting experience.