TRUNNION MOUNT INSTALLATION: (Figure 11)

Note: Use minimum 90°C supply wire when installed per below procedure and connections are made inside of condulet body.

Note: For 8-3/8” to 13-1/4” vertical adjustment (Up or Down only).

1.Install top trunnion on the ceiling using masonry anchors (provided by others).

2.Apply sealing compound (by others) on one end of ½” nipple.

3.Screw nipple into the housing.

4.Install bottom trunnion L-brackets on the top plate (with provided #10-24 pan head screws, lock washers and nuts—Torque between 24-27 in-lb).

5.Install top plate on the housing (with provided #10-24 flat head screws— Torque between 24-27 in-lb).

6.Pull wires from back of luminaire through nipple to make for easy routing into condulet body.

7.Apply sealing compound to top of nipple. Screw condulet body onto nipple.

8.Install bottom trunnion L-brackets to the top trunnion (with provided 3/8" bolts, lock washers and nuts—Torque between 17-20 ft-lb).

9.Route conduit and power supply wires to condulet body.

10.Make connections. Push excess wires and connectors back into the condulet body.

11.Install gasket and cover.

TASK LIGHT INSTALLATION: (Figure 12)

WARNING: RISK OF FIRE! DO NOT mount on or near combustible materials.

1.Apply sealing compound on the threads of handle (provided by others).

2.Screws handle into adapter.

3.Aim handle to a preferred position and lock it in position.

4.Aim task light head to a preferred position and tighten #10-24 Allen head screw (with provided Allen wrench).

5.Pull wires through access and restrain with wire tie.

Note: Depending on which task light option is being ordered, additional wiring/routing will be necessary. Reference wiring diagrams shipped with task light.

Figure 11

CONDULET

 

 

BODY

3/8” BOLT

TOP

 

 

TRUNNION

 

 

 

 

COVER

 

 

GASKET

 

 

#10-24 FLAT

 

 

CS SCREW

TOP PLATE

 

BOTTOM

 

 

TRUNNION

NIPPLE

 

 

APPLY SEALING

 

HOUSING

COMPOUND

 

 

 

(BY OTHERS)

 

 

#10-24

 

 

SCREW

 

 

 

FOR VERTICAL ADJUSTMENT (UP OR DOWN ONLY)

 

8-3/8 TO 13-1/4” FROM TOP OF LUMINAIRE

 

 

 

 

 

 

Figure 12

 

HANDLE

 

 

(APPLY SEALING

 

 

COMPOUND BY OTHERS)

TASK LIGHT

HEAD

ADAPTER

#10-24

ALLEN HEAD

LOCK NUT

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.

NOTE: Specifications and dimensions subject to change without notice.

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH080771

Image 4
Contents Sheet 1 Luminaire InstallationFixture Orientation Guideline Sheet 2 Removal of LuminaireTamper-resistant option Figure Pull luminaire forward FigureLamp Installation Sheet 3Sheet 4 THRU-BRANCH Wiring Installation Sheet 5

IMI-694 specifications

Cooper Lighting's IMI-694 is a sophisticated and versatile fixture designed to meet the lighting demands of various environments while offering exceptional performance and energy efficiency. This innovative luminaire is tailored for commercial and industrial applications, ensuring optimal functionality combined with advanced technology.

One of the standout features of the IMI-694 is its exceptional luminance output and uniform light distribution. Equipped with high-efficiency LED sources, it provides bright, consistent illumination that enhances visibility in workspaces, retail environments, and public areas. The fixture’s design minimizes shadows and glare, creating a comfortable visual experience for occupants.

The IMI-694 boasts a durable construction, featuring a robust housing made from high-quality materials that resist wear and corrosion. This rugged design makes it ideal for harsh environments, including manufacturing facilities, warehouses, and outdoor applications. Additionally, the fixture is available in various color temperatures, allowing users to select the ideal ambiance for their specific needs, whether that is a cooler light for increased productivity or a warmer tone for a more relaxed atmosphere.

Another significant advantage of the IMI-694 is its compatibility with advanced lighting control technologies. The fixture can be easily integrated with dimmers, occupancy sensors, and daylight harvesting systems, which contribute to substantial energy savings while providing tailored lighting solutions. This level of integration is especially beneficial for facilities aiming to enhance sustainability and reduce operational costs.

Maintenance is also simplified with the IMI-694, thanks to its long lifespan and easy-access features. The LED technology reduces the frequency of replacements, making it a cost-effective choice for long-term projects. Furthermore, the fixture is designed to offer easy installation, with versatile mounting options that accommodate various ceiling heights and configurations.

In summary, Cooper Lighting's IMI-694 combines advanced LED technology, durability, and flexibility, making it an excellent choice for a wide array of applications. Its energy-efficient performance and compatibility with modern lighting controls position it as a suitable solution for those looking to improve their lighting systems while being mindful of budget and environmental impact. With the IMI-694, users can expect exceptional reliability, enhanced productivity, and an overall improved lighting experience.