Nordyne B5SM -090 installation instructions Typical Heat Pump Thermostat Connections

Page 15

NOTES:

TO FIELD

1. Jumper between W2 and E is required.

SUPPLIED DISCONNECT

 

2. C &W2 to be connected to electric heat.

GND

 

SINGLE STAGE

 

HEAT PUMP THERMOSTAT

L1

R O W2 E C G Y B

L2

 

L3

NOTE 1

 

BLOWER

MOTER

 

FREEZESTAT

 

BROWN

 

G

GREEN

C

C

BLACK

 

W2

W2

 

O

O

NOTE 2

R

R

BLACK

Y

Y

 

W1

 

 

TERMINAL

OUTDOOR

BOARD

 

AIR HANDLER

SECTION

 

SECTION

TYPICAL HEAT PUMP THERMOSTAT CONNECTION (NO ECONOMIZER)

 

 

 

 

 

TO FIELD

 

 

 

 

 

 

 

SUPPLIED DISCONNECT

 

 

 

 

 

 

GND

 

 

 

SINGLE STAGE

 

 

 

 

 

 

HEAT PUMP THERMOSTAT

 

 

 

L1

R

O W2 E C G

Y

B

 

 

L2

 

 

 

 

 

 

 

L3

 

NOTE 1

 

 

 

 

 

BLOWER

 

 

 

 

 

 

 

 

 

 

 

 

MOTER

 

 

 

 

FREEZESTAT

NOTE 5

 

 

 

 

B

GREY

 

 

 

 

BROWN

BLACK

 

 

 

 

Y1

YELLOW

 

 

 

 

 

GREEN

NOTE 3

 

 

 

 

 

G

 

 

 

 

 

 

BLACK

 

GREEN

C

 

 

 

C

 

 

 

 

 

 

 

BLACK

W2

 

 

 

W2

 

 

 

 

 

 

 

 

O

 

 

 

O

NOTE 2

 

 

R

 

 

 

R

 

WHITE

 

 

 

 

 

Y

 

 

 

Y

NOTE 4 Y2

ORANGE

 

 

 

 

W1

BLUE

 

 

 

 

TERMINAL

 

 

RED

 

 

 

 

BOARD

 

 

RED

 

 

 

 

 

 

 

OUTDOOR

 

 

 

 

AIR HANDLER

C7150

 

SECTION

 

 

 

 

SECTION

M.A.S.

 

NOTES:

1.Jumper between W2 and E is required.

2.C & W2 to be connected to electric heat.

3.Remove BLACK wire from air handler low voltage terminal board Y terminal and connect to YELLOW wire from economizer.

4.2nd Stage refrigerant cooling with optional economizer installed. A 2 stage thermostat is required for simultaneous operation of the economizer and refrigerant system. Connect Y2 from 2 stage thermostat to BLUE wire from economizer. If installing an economizer in this unit, refer to the Economizer installation instructions for proper set up and operation.

5.Heat Pump Economizer Relay. Connect B from thermostat to GREY wire from Economizer. Required for proper operation of an economizer (optional) in the heat pump Heating mode. If installing an economizer in this unit, refer to the Economizer installation instructions for proper set up and operation.

 

GRY-90”

 

 

W7459A

TB-11

M7415A

A

B

GRN-18”

 

 

 

 

TR

7

9

TR

 

TR 1

 

 

GRN-18”

 

 

 

 

 

 

 

 

BLK-12”

TR1

 

 

 

 

 

 

 

4

6

 

VIO-14”

So

 

 

 

 

s

BLU-14”

 

 

 

 

1

3

 

 

JUMPER

 

 

C7400A

 

 

 

 

 

 

 

 

Sr

 

 

 

 

 

 

 

 

WIRE

 

 

 

 

 

 

 

 

5

 

 

 

 

YEL-18”

 

 

 

 

 

 

 

 

 

1

2

1S

 

 

 

 

 

 

3

4

2K

 

T

 

 

 

 

 

RED-12”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1S

T1MA

 

 

 

 

T

 

T1

GRY-12”

 

 

 

 

 

 

 

 

 

 

OPTIONAL

 

P

 

P1

BLK-12”

P1

 

 

 

 

 

 

MIN.

 

 

ECONOMIZER

 

 

 

 

BLU-12”

P POT.

TYPICAL HEAT PUMP THERMOSTAT CONNECTION (WITH ECONOMIZER)

Figure 8. Typical Heat Pump Thermostat Connections

15

Image 15
Contents Vertical Application Horizontal Application Rear View Installation InstructionsPhysical Dimensions Horizontal Nitrogen Important Safety InformationLocating the Air Handler Before You Install the Air HandlerField Connections for Electrical Power Supply General InformationHorizontal Mounting Applications AIR Handler Installation Packaging RemovalConnecting Refrigerant Tubing Minimum Clearance RequirementsFilter Requirements Pressure Drop Across FiltersElectrical Rating Data Electrical Wiring Example Unbalanced 3-Phase Supply VoltageStartup and Adjustments Pre-Start Check List Motor Sheave AdjustmentUnit Maintenance 2 Ton Unit Refrigerant Line Connections Ton Unit Refrigerant Line ConnectionsFront View Side View Top View4182 666 Blower Performance DataTo yellow wire from economizer Three Phase only NotesGeneral Notes Typical Air conditioner Thermostat Connections Typical Heat Pump Thermostat Connections 7090950 Maintenance Schedule