Electro-Voice Plasma Series P1 and P2 Amplifiers, Input, Outputs, Crossover Mode Switch, Level

Page 6

P1 and P2 Amplifiers

Input

Electronically balanced inputs for the connection of high-level signal sources such as mixers, signal processors, etc. Establishing the connection is possible via phone or XLR-type jacks. Balanced connection is recommended to prevent noise or HF-interference.

Caution: Before connecting or disconnecting any plugs, make sure to set the level control to its counterclockwise stop, which prevents the system, the audience and yourself from being stressed by nasty contact noise.

Outputs

Output is full bandwidth pass through.

Crossover Mode Switch

Selects between 40 Hz highpass filter for Fullrange use, and 100 Hz highpass filter for use with Plasma P2 subwoofer. It is not recommended that you use your P1 in Fullrange with subwoofers.

Level

This control sets the output volume of the P1 or P2 in a range between -dB and +6dB. The internal power amplifier provides a nominal input sensitivity of +6dBu.

Level adjustment knob shown in place. Unit is shipped preset at 0 dB without knob installed (knob is shipped separately with your Plasma Speaker). If knob is not used, please remember where you store it. Customer can adjust level by removing cover, pressing knob in place, and rotating to desired level.

5

ELECTRO-VOICE®￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

Image 6
Contents Plasma Series Important Safety Instructions Important Service InstructionsFor US and Canada only Table of Contents Safety First Make sure toSystem Features Plasma System SetupDescription Input Crossover Mode SwitchP1 and P2 Amplifiers OutputsAC Connector Status IndicatorsPower Switch AC FuseSetup Diagrams for Plasma Using Plasma P1’s as Floor Monitors Plasma P1 RiggingSuspending Plasma P1 Speaker Systems Specifications Dimensions Plasma P1Dimensions Plasma P2 Subwoofer Block Diagrams ELECTRO-VOICE ELECTRO-VOICE ELECTRO-VOICE