Heat Controller EKTC12-1G, EKTH15-1G Extended Performance Data, Extended Cooling Performance

Page 12

PACKAGED TERMINAL A/C

 

 

 

 

 

Service Manual

 

 

 

 

 

 

 

Heat Controller

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Extended Performance Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXTENDED COOLING PERFORMANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR DRY BULB TEMP. (DEGREES F AT 40% R.H.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

 

 

 

85

 

 

95

 

 

 

105

 

 

110

 

 

 

 

 

 

 

 

INDOOR WET BULB TEMP. (DEGREES F AT 80 F D.B.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

67

62

 

72

 

67

62

72

67

62

72

 

67

62

72

67

62

 

 

 

BTUh

9055

8709

8062

 

8624

 

8131

7500

8285

7700

6815

7762

 

6892

6076

6907

5944

5251

 

 

EKTC07

WATTS

522

530

536

 

569

 

575

582

640

640

640

691

 

691

693

755

755

758

 

 

AMPS

2.5

2.5

2.6

 

2.7

 

2.8

2.8

3

3

3

3.3

 

3.3

3.3

3.6

3.6

3.6

 

 

 

 

 

 

 

 

 

SHR

0.58

0.79

0.95

 

0.59

 

0.81

0.99

0.59

0.84

0.99

0.6

 

0.88

0.99

0.63

0.95

0.99

 

 

 

BTUh

10584

10179

9423

 

10080

 

9504

8766

9684

9000

7965

9072

 

8055

7101

8073

6948

6138

 

 

EKTC09

WATTS

653

663

670

 

711

 

719

727

800

800

800

865

 

864

866

943

943

947

 

 

AMPS

3.3

3.3

3.3

 

3.5

 

3.5

3.5

3.9

3.9

3.9

4.2

 

4.2

4.2

4.6

4.6

4.6

 

 

 

 

 

 

 

 

 

SHR

0.56

0.75

0.91

 

0.57

 

0.79

0.92

0.57

0.81

0.92

0.58

 

0.86

0.94

0.62

0.91

0.92

 

 

 

BTUh

14112

13573

12565

 

13440

 

12672

11688

12912

12000

10621

12096

 

10741

9469

10765

9264

8184

 

 

EKTC12

WATTS

914

928

938

 

996

 

1006

1018

1120

1120

1120

1210

 

1209

1213

1321

1321

1326

 

 

AMPS

4.4

4.4

4.4

 

4.7

 

4.7

4.8

5.3

5.3

5.3

5.7

 

5.7

5.7

6.3

6.3

6.3

 

 

 

 

 

 

 

 

 

SHR

0.46

0.62

0.84

 

0.47

 

0.65

0.86

0.47

0.67

0.86

0.48

 

0.71

0.87

0.51

0.75

0.86

 

 

 

BTUh

17640

16965

15705

 

16800

 

15840

14610

16140

15000

13275

15120

 

13425

11835

13455

11580

10230

 

 

EKTC15

WATTS

1248

1269

1282

 

1360

 

1373

1391

1530

1530

1530

1654

 

1652

1657

1803

1803

1812

 

 

AMPS

6.2

6.2

6.3

 

6.6

 

6.8

6.8

7.5

7.5

7.5

8.0

 

8.0

8.1

8.8

8.8

8.8

 

 

 

 

 

 

 

 

 

SHR

0.45

0.60

0.81

 

0.46

 

0.63

0.83

0.46

0.65

0.83

0.47

 

0.69

0.84

0.49

0.74

0.83

 

 

 

 

 

 

 

 

 

 

 

 

RATING POINT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ARI 310/380

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXTENDED COOLING PERFORMANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR DRY BULB TEMP. (DEGREES F AT 40% R.H.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

 

 

 

85

 

 

95

 

 

 

105

 

 

110

 

 

 

 

 

 

 

 

 

INDOOR WET BULB TEMP. (DEGREES F AT 80 F D.B.)

 

 

 

 

 

 

 

 

 

72

67

62

 

72

 

67

62

72

67

62

72

 

67

62

72

67

62

 

 

 

BTUh

9055

8709

8062

 

8624

 

8131

7500

8285

7700

6815

7762

 

6892

6076

6907

5944

5251

 

 

EKTH07

WATTS

522

530

536

 

569

 

575

582

640

640

640

691

 

691

693

755

755

758

 

 

AMPS

2.5

2.5

2.6

 

2.7

 

2.8

2.8

3

3

3

3.3

 

3.3

3.3

3.6

3.6

3.6

 

 

 

 

 

 

 

 

 

SHR

0.58

0.79

0.95

 

0.59

 

0.81

0.99

0.59

0.84

0.99

0.6

 

0.88

0.99

0.63

0.95

0.99

 

 

 

BTUh

10584

10179

9423

 

10080

 

9504

8766

9684

9000

7965

9072

 

8055

7101

8073

6948

6138

 

 

EKTH09

WATTS

653

663

670

 

711

 

719

727

800

800

800

865

 

864

866

943

943

947

 

 

AMPS

3.3

3.3

3.3

 

3.5

 

3.5

3.5

3.9

3.9

3.9

4.2

 

4.2

4.2

4.6

4.6

4.6

 

 

 

 

 

 

 

 

 

SHR

0.56

0.75

0.91

 

0.57

 

0.79

0.92

0.57

0.81

0.92

0.58

 

0.86

0.94

0.62

0.91

0.92

 

 

 

BTUh

14112

13573

12565

 

13440

 

12672

11688

12912

12000

10621

12096

 

10741

9469

10765

9264

8184

 

 

EKTH12

WATTS

914

928

938

 

996

 

1006

1018

1120

1120

1120

1210

 

1209

1213

1321

1321

1326

 

 

AMPS

4.4

4.4

4.4

 

4.7

 

4.7

4.8

5.3

5.3

5.3

5.7

 

5.7

5.7

6.3

6.3

6.3

 

 

 

 

 

 

 

 

 

SHR

0.46

0.62

0.84

 

0.47

 

0.65

0.86

0.47

0.67

0.86

0.48

 

0.71

0.87

0.51

0.75

0.86

 

 

 

BTUh

17640

16965

15705

 

16800

 

15840

14610

16140

15000

13275

15120

 

13425

11835

13455

11580

10230

 

 

EKTH15

WATTS

1248

1269

1282

 

1360

 

1373

1391

1530

1530

1530

1654

 

1652

1657

1803

1803

1812

 

 

AMPS

6.2

6.2

6.3

 

6.6

 

6.8

6.8

7.5

7.5

7.5

8.0

 

8.0

8.1

8.8

8.8

8.8

 

 

 

 

 

 

 

 

 

SHR

0.45

0.60

0.81

 

0.46

 

0.63

0.83

0.46

0.65

0.83

0.47

 

0.69

0.84

0.49

0.74

0.83

 

 

 

 

 

 

 

 

 

 

 

 

RATING POINT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ARI 310/380

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

Image 12
Contents Packaged Terminal Air Conditioners & Heat Pumps Dimensional Data Unit nomenclatureBTU/H Model RevisionUnit components Specification and Technical Parameters EKTC07-1G EKTH07-1GFunction G4C085IUBJP G4C085YUAJP Refrigerant Charge oz. kg 410A 33.5 ozEKTH12-1G G4A110IUBJPEKTH12-2G G4A110YUAJPEKTC15-1G EKTH15-1G EKTC15-2G EKTH15-2G Extended Performance Data Extended Cooling PerformanceRating Point Controller Functions and Operating Methods System Basic FunctionController Function and Operating Method Button and DisplaysSpecial Functions and Features Energy Management InputAWG Wire Size no Wall Thermostat Connections Typical Wiring Diagram Unit controls Temp ControlKeypad Configuration DIP Switches Protective Features Electric Circuit Diagram Power Connection Options Preventative Maintenance Trouble Shooting Guide Cooling Heating

EKTH09-2G, EKTH09-1G, EKTH07-2G, EKTH15-1G, EKTC07-2G specifications

The Heat Controller EKTC15-2G, EKTC09-2G, EKTC12-2G, EKTH12-1G, and EKTH12-2G models represent a cutting-edge advancement in the realm of heating solutions, designed to deliver efficient and reliable performance. With a commitment to energy efficiency and user comfort, these models cater to diverse heating needs in various residential and commercial environments.

One of the standout features of these models is their advanced heat pump technology. This technology allows the units to extract ambient heat from the air, even in chilly conditions, maximizing efficiency and minimizing energy consumption. The EKTC and EKTH series offer rapid heating performance, ensuring that spaces are warmed swiftly and effectively.

Each model is equipped with intelligent control systems that allow users to set specific temperature preferences. The digital thermostat ensures precise temperature regulation, enhancing comfort while optimizing energy use. Additionally, the user-friendly interfaces are designed for ease of operation, enabling quick adjustments to heating settings.

Energy efficiency is a hallmark of the EKTC and EKTH series, with many models achieving high Seasonal Energy Efficiency Ratios (SEER). These ratings indicate lower energy costs and a reduced carbon footprint, making them an eco-friendly choice for consumers conscious of environmental impacts.

Noise reduction technology is another significant characteristic of these heaters. The whisper-quiet operation ensures minimal disruption, making these models suitable for bedrooms, offices, and other quiet spaces.

Moreover, the adaptable designs of the EKTC and EKTH series allow for installation flexibility, catering to various room sizes and layouts. Whether it's a compact unit for a smaller space or a robust model for larger areas, there’s an option suitable for every requirement.

Safety features are also paramount in the design of these heating units. Overheat protection and automatic shutoff mechanisms provide peace of mind, preventing any potential hazards.

In closing, the Heat Controller EKTC15-2G, EKTC09-2G, EKTC12-2G, EKTH12-1G, and EKTH12-2G models stand out for their superior performance, energy efficiency, and user-centric features. They are designed to meet the needs of modern heating requirements, providing warmth and comfort while keeping energy consumption in check. Whether for residential use or commercial application, these heating solutions embody the perfect blend of innovation and practicality.