Owner’s Manual | Room Air Heat Pump with | Heat Controller, Inc. | |
|
|
|
|
|
|
|
|
Ins tallation Ins tructions
6 INSTALL THE CASE
IN THE WINDOW (cont.)
DAdjust the leveling bolts and nuts against the outside wall so that the case has a slight tilt to the outside. Tighten nuts with an adjustable wrench. Use a level; about a 1/2 bubble will be the correct case slant to the outside.
EUse a wood block (obtained locally) between the leveling bolts and the wall if the wall is weak or if the weight of the air conditioner falls between the studs in the wall.
FExtend the left and right accordion panels to the vertical window sashes. Drill pilot holes and attach the top and bottom corners with 4 type D screws.
Top mounting rail
Type D
screwType D screw
Type D screw
Type D screw
7
A
B
C
INSTALLSUPPORTBRACKETSBRACKETS
ANDTOP WINDOW FOAM GASKET
THE FOAM TOP WINDOW
GAS KET
Attach the support brackets with two type D screws, one on each side.
Cut the foam top window gasket to the the top window foam gasket to the window
widthindow. width.
Stuff the foam between the glass and the the foam between the glass and the window
towindowprevent toairpreventfrom gettingair intoandtheinsectsroom. from
getting into the room .
10