Heat Controller RAD-183A, RAD-243A service manual Cabinet Installation

Page 11

Installation

Cabinet Installation

1. Open the window. Mark a line on the center of the

 

window stool between the side window stop mold-

Sill

ings.

Bracket

Loosely attach the sill bracket to the support bracket

Carriage

using the carriage bolt and the lock nut.

Bolt

 

(M-Screw)

 

 

Support Bracket

Lock nut

Figure 6

2.Attach the sill bracket to the window sill using the screws (Type B).

Carefully place the cabinet on the window stool and align the center mark on the bottom front with the center line marked window stool.

Cabinet

Track hole

Support

Bracket

Carriage bolt

Machine screw(Type D) and lock nut

Outer edge of window sill

Screw(Type B)

3.Using the M-screw and the lock nut, attach the sup- port bracket to the cabinet track hole. Use the first track hole after the sill bracket on the outer edge of the window sill. Tighten the carriage bolt and the lock nut. Be sure the cabinet slants outward.

and lock nut

Sill bracket

Figure 7

CAUTION: Do not drill a hole in the bottom pan. The unit is designed to operate with approximately 1/2" of water in bottom pan.

Top retainer bar

Window sash

Top

Front angle

retainer bar

Window stool

Figure 8

4.Pull the bottom window sash down behind the Top retainer bar until they meet.

NOTICE

1.Do not pull the window sash down so tightly that the movement of Frame curtain is restricted. Attach the cabinet to the window stool by driving the screws (Type B) through the cabinet into window stool.

2.The cabinet should be installed with a very slight tilt downward toward the outside.

Foam-PE

Cabinet

Frame curtain

Foam-PE

Figure 9

Sash track

 

Front Angle

Screw(Type B)

Figure 10

 

11Room Air Conditioner

Image 11
Contents +$7&21752//5,1& Table of Contents Be sure not to do Be sure to follow the instruction Safety PrecautionsDo not modify or extend the power cord Outside Dimensions DimensionsSymbols Used in this Manual Items Models Product Specifications760/1,850 Select the Best Location Installation Installation Check How to Secure the Drain PipeWindow Requirements Installation Kits ContentsPreparation of Chassis Suggested Tool RequirementsCabinet Installation Installation Cooling Only Model FeaturesOperation Control Locations Function of ControlsRAD-183A, RAD-243A Display Remote ControlCabinet DisassemblyMechanical Parts Front GrilleFan Cover at the topBlower Compressor Electrical PartsShroud MotorSynchronous Motor Power CordCapacitor ThermistorCapillary Tube Refrigerating CycleEvaporator Disassembly Pulling Vacuum CN-TH1 DiagramModel RAD-183A and RAD-243A Wiring DiagramComponents Location Main P.W.B Assembly Display P.W.B AssemblyPiping System Troubleshooting GuideUnit runs but poor cooling Troubleshooting GuideFails to Start Possible Trouble Electrical Parts Troubleshooting GuideIC01M 0V? IC01M DC 5V? Delay? IC01M 0V? Possible Trouble 6 Remote controller does not operate Complaint Cause Remedy Room Air Conditioner Voltage LimitsTroubleshooting Guide Troubleshooting Guide Cooling Model Exploded ViewRemark 35211A Replacement Parts List LocNoGrille ASSY,FrontSINGLE Grille ASSY,INLET+$7&21752//5,1&