Haier AS102AMARA, AU102ACARA Operation, Cutting hose Removing burr, Put on nut Expand Hose

Page 9
26
Piping Connection
Hose Expander
A

Installation

Localize the Installation:

Indoor Unit

Install the indoor unit where the weight of the unit can be supported.

Install the indoor unit where the head source and steam source are not close and the unit inlet and outlet are not blocked.

Install the indoor unit where the drainage is easy and the outdoor unit can easily connected.

Install the indoor unit where its cold air and hot air can be easily sent to all the corners of the room.

Install the indoor unit where the power socket is near and there is sufficient space around the indoor unit.

Install the indoor unit where there is no T.V set, radio set, and wireless appliance underneath, and the sunlight lamp is over one meter away.

If the remote controller is installed on the wall, the indoor unit shall be ensured to receive the signal while the sunlight lamp is on.

Outdoor Unit

The location shall bear the weight of the unit and will not produce a big vibration and noise.

The location shall be in good ventilation,and the airflow blew out and noise produced shall not affect the neighbors.

The location shall not be directly drenched in rain,sun,or blew by sea wind.

The location shall not be near anywhere the corrosive gas(SO2),flammable gas(thinner or gasoline),oil mist,or steam are probably produced(for example in kitchen).

Sufficient space shall be left for air inlet and outlet.

The location shall be easily maintained and repaired.

It cannot be installed on a non-professional metal structure(like anti-burglary net).

Method for Cutting and Expanding Pipes:

When the pipe is too long or its mouth is damaged,the pipe needs to cut or expand.

 

1.Cutting hose

2.Removing burr

Expansion Size

 

 

 

 

 

Hose dia.

Size(mm)

 

Liquid hose

6.35 mm(1/4")

0.8-1.5

 

Gas hose

9.52 mm(3/8")

1.0-1.8

3.Put on nut

4.Expand Hose

12.7 mm(1/2")

1.2-2.0

Operation

Remote Controller, s Operation

When in use, point the signal sending head directly to the receiver window on the indoor unit. The distance between the signal sending head and the receiver window should be within 7 m without any obstacle as well.

Don't throw the controller, prevent it from being damaged.

When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals so the distance to the indoor unit should be shorter.

Loading of Batteries

Load the batteries as illustrated in the drawing below:

Remove Battery Cover:

Slightly press and push down the cover. Then , as the drawing, hold the upper end of the remote controller with left hand, and slightly hold the cover with right hand, push slightly in

1. Connecting Method

To ensure the efficiency,the pipe should be as short as

 

possible.

 

 

 

 

Apply refrigerant oil at half union and flare nut.

 

To bend a pipe,five the roundness as large as possibleSpanner

not to crash the pipe.

 

 

 

When connecting pipe,hold the pipe center to center

 

then screw nut on by hand,refer to the Drawing.

Correct

 

 

 

 

Be careful not to let foreign matters,such as sands enter

 

the pipe.

 

 

 

 

 

 

 

 

 

Pipe dia.

 

Recommended

 

 

 

 

Fastening Torque

 

 

Liquid pipe

6.35mm(1/4")

18 N.m

 

 

Gas Pipe

9.52mm(3/8")

42 N.m

 

 

Gas Pipe

12.7mm(1/2")

50 N.m

 

 

Refrigeration Oil

Connector Nut

Spanner

Not Correct

cracks on

Tilting expanded burr incomplete too long mouth

the arrow direction to remove the battery cover .

Load Batteries:

Be sure that the loading is in line with the + / -

as illustrated.

Put back Cover:

Put back the cover in the reverse procedure.

Confirmation Indicator:

If there is no display after pressing the on/off button, reload the batteries.

Notes: Use two same-typed batteries when loading.

If the remote controller cannot run normally or doesn't work at all, use a sharp pointed

item to press the reset button (with the mark

 

).

 

 

7

Image 9
Contents Split AIR Conditioner Contents Safety Instructions and Warnings Disposal of the old air conditionerDisposal of the packaging of your new air conditioner Specifications Installation Check and Trial OperationInstallation Name of Parts Indoor Unit Wiring for Indoor and Outdoor UnitsOutdoor Unit Installation Remote ControllerPiping Connection for Outdoor Unit Installation Operation Hints Piping Protective CoverDrain Elbow Drain Hose Installation of Indoor Unit Operation Hints InstallationCold Air Prevention DefrostOperation Refrigeration Oil Connector Nut SpannerCutting hose Removing burr Put on nut Expand HoseCancel Healthy Operation Set Healthy OperationBrief Introduction to Health Operation Electrical Requirements Select Temperature Setting Press Temp. buttonTurn on the Air Conditioner Hose SelectionLeft and Right Adjustmentmanual Adjustment of Air Flow DirectionInstallation Tools Self-contained AccessoriesTimer Setting Installation Drawing for Indoor and Outdoor UnitsTime Setting Time Set OperationTrouble Shooting Trouble Shooting Operation Followings are not malfunction HuaMaintenance Maintenance after Season of UseMaintenance before Season of Use Clean the Air Conditioner Installation and Replacement of Air FilterDust Filter Air Filter

AS102ALARA, AS122AYARA, AU122ACARA, AS122AVARA, AS102AMARA specifications

The Haier AU102ACARA, AS102AMARA, AS122AVARA, AU122ACARA, and AS122AYARA air conditioning units exemplify innovative design and advanced technology aimed at providing optimum comfort in various environments. These models are suited for both residential and commercial applications, showcasing efficiency and quiet operation, essential for any space.

One of the key features of these Haier models is their energy efficiency. Each unit is designed with advanced inverter technology that adjusts the compressor speed seamlessly to maintain the desired temperature. This not only provides better cooling performance but also leads to significant energy savings, making it an environmentally friendly choice.

The units are equipped with smart capabilities, enabling users to control their air conditioning systems through mobile apps. This allows for greater flexibility and convenience, as users can adjust their settings from anywhere, ensuring their environment is always comfortable upon arrival.

In addition to smart controls, these models feature a sleek, modern design that blends easily with any decor. The compact form factor is particularly appealing for urban living spaces where every square foot counts. Moreover, these air conditioners are equipped with high-density filters that provide exceptional air purification, capturing dust, allergens, and pollutants to improve indoor air quality.

The Haier AU102ACARA and AS102AMARA are particularly noted for their compact size and efficiency, making them ideal for smaller rooms. The AU122ACARA and AS122AYARA, on the other hand, offer increased cooling capacities, suitable for larger spaces while maintaining the same high efficiency standards.

Noise levels are another consideration with the Haier models, which operate at whisper-quiet levels, ensuring that indoor tranquility is preserved. This feature is crucial for bedrooms or study areas where distractions should be kept to a minimum.

In summary, the Haier AU102ACARA, AS102AMARA, AS122AVARA, AU122ACARA, and AS122AYARA air conditioning units combine energy efficiency, smart technology, modern aesthetics, effective air filtration, and low noise operation, making them excellent choices for anyone looking to enhance their indoor comfort. With their various capacities and features, these models cater to a wide range of needs, ensuring a pleasant environment throughout the year.