Giant LP200 service manual Model LP250, LP250W-MT, LP250 Horsepower Requirements

Page 6

 

Specifications

Model LP250, LP250W-MT

Volume

Up to 26.0 GPM

Discharge Pressure

Up to 2200 PSI

Inlet Pressure

Up to 90 PSI

Speed

Up to 1000 RPM

Plunger Diameter

32 mm

Stroke

42 mm

Crankcase Oil Capacity

100 fl.oz.

Temperature of Pumped Fluids

Up to 140 oF

Inlet Port

1-1/24" BSP

Discharge Port

3 x 1" BSP

Crankshaft Mounting

Either Side

Shaft Rotation

Top of Pulley Towards Fluid End

Weight

110 lbs.

Crankshaft Diameter

35 mm

*Intermittent duty for pump speeds in excess of 805 RPM

PULLEY INFORMATION

Pulley selection and pump speed are based on a 1725 RPM motor and "B" section belts. When selecting desired GPM, allow for a ±5% toler- ance on pumps output due to variations in pulleys, belts and motors among manufactur- ers.

1.Select GPM required, then select appropriate motor and pump pulley from the same line. 2.The desired pressure is achieved by selecting the correct nozzle size that corresponds with the pump GPM.

HORSEPOWER INFORMATION

We recommend that a 1.1 service factor be specified when selecting an electric motor as the power source. To compute specific pump horsepower requirements, use the following formula:

HP = (GPM X PSI) / 1440

LP250 HORSEPOWER REQUIREMENTS

 

RPM

 

GPM

1000 PSI

1500 PSI

2000 PSI

2200 PSI

 

 

500

13.0

9.0

13.5

18.0

19.8

 

 

640

16.6

11.5

17.3

23.1

25.4

 

 

750

19.5

13.5

20.3

27.1

29.8

 

 

805

20.9

14.5

21.8

29.0

31.9

 

 

865

22.5

15.6

23.4

31.2

34.3

 

 

920

23.9

16.6

24.9

33.2

36.5

 

 

1000

26.0

18.0

27.1

36.1

39.7

 

6

Image 6
Contents Contents Updated 5/02Installation Instructions Important Operating Conditions LP200 Horsepower Requirements Model LP200Exploded View LP200, LP250 & LP250W-MT LP200, LP250 & LP250W-MT Parts List LP200, LP250 & LP250W-MT Repair KitsLP250W-MT LP250 Horsepower Requirements Model LP250, LP250W-MTLP200, LP250 & LP250W-MT Repair Instructions 44A 44BLP200, LP250 & LP250W-MT Repair Instructions Bushings LP200, LP250 & LP250W-MT Torque SpecificationsPosition Item# Description Pulley & SheavesPump System Malfunction Malfunction Cause RemedyLP200, LP250 & LP250W-MT Dimensions Giant Industries Limited Warranty