Precaution for Installation

Safety precautions

Please read these "Safety Precautions" first then accurately execute the installation work.

Though the precautionary points indicated herein are divided under two headings, WARNING and CAUTION, those points which are related to the strong possibility of an installation done in error resulting in death or serious injury

are listed in the

WARNING section. However, there is also a possibility of serious consequences in relationship to the

points listed in the

CAUTION section as well. In either case, important safety related information is indicated, so by all

means, properly observe all that is mentioned.

After completing the installation, along with confirming that no abnormalities were seen from the operation tests, please explain operating methods as well as maintenance methods to the user (customer) of this equipment, based on the owner's manual. Moreover, ask the customer to keep this sheet together with the owner's manual.

WARNING

This system should be applied to places as office, restaurant, residence and the like. Application to inferior environment such as engineering shop could cause equipment malfunction.

Please entrust installation to either the company which sold you the equipment or to a professional contractor. Defects from improper installations can be the cause of water leakage, electric shocks and fires.

Execute the installation accurately, based on following the installation manual. Again, improper installations can result in water leakage, electric shocks and fires.

When a large air-conditioning system is installed to a small room, it is necessary to have a prior planned countermeasure for the rare case of a refrigerant leakage, to prevent the exceeding of threshold concentration. In regards to preparing this countermeasure, consult with the company from which you perchased the equipment, and make the installation accordingly. In the rare event that a refrigerant leakage and exceeding of threshold concentration does occur, there is the danger of a resultant oxygen deficiency accident.

For installation, confirm that the installation site can sufficiently support heavy weight. When strength is insufficient, injury can result from a falling of the unit.

Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and hurricanes, etc. Improper installations can result in accidents due to a violent falling over of the unit.

For electrical work, please see that a licensed electrician executes the work while following the safety standards related to electrical equipment, and local regulations as well as the installation instructions, and that only exclusive use circuits are used.

Insufficient power source circuit capacity and defective installation execution can be the cause of electric shocks and fires.

Accurately connect wiring using the proper cable, and insure that the external force of the cable is not conducted to the terminal connection part, through properly securing it. Improper connection or securing can result in heat generation or fire.

Take care that wiring does not rise upward, and accurately install the lid/service panel. Its improper installation can also result in heat generation or fire.

When setting up or moving the location of the air conditioner, do not mix air etc. or anything other than the designated refrigerant (R410A) within the refrigeration cycle.

Rupture and injury caused by abnormal high pressure can result from such mixing.

Always use accessory parts and authorized parts for installation construction. Using parts not authorized by this company can result in water leakage, electric shock, fire and refrigerant leakage.

CAUTION

Execute proper grounding. Do not connect the ground wire to a gas pipe, water pipe, lightning rod or a telephone ground wire. Improper placement of ground wires can result in electric shock.

The installation of an earth leakage breaker is necessary depending on the established location of the unit. Not installing an earth leakage breaker may result in electric shock.

Do not install the unit where there is a concern about leakage of combustible gas.

The rare event of leaked gas collecting around the unit could result in an outbreak of fire.

For the drain pipe, follow the installation manual to insure that it allows proper drainage and thermally insulate it to prevent condensation. Inadequate plumbing can result in water leakage and water damage to interior items.

12

Image 13
Contents Duct Type AIR Conditioner Contents Disposal of the old air conditioner Safety Instructions and WarningsDisposal of the packaging of your new air conditioner Safety Precautions Shock Machine is adaptive in following situation Indoor Unit Parts and FunctionsOutdoor Unit HOT Keep function Heating ModeWarming Operation Care and Maintenance Cooling or heating is not sufficient TroubleshootingCooling Is not sufficient Followings are not malfunction ShuruDiagnosis for On-Off models Shows resumable fault, shows it is not resumable faultSafety precautions Precaution for InstallationWhen you change your address or the installation place Is the Unit Installed CorrectlyFor inspection and maintenance Electric workHeight of ceiling Installation PrecedureInstalling indoor unit Indoor Unit Preparation before installationAdjusting to the levelness Indoor Unit Drain Piping ProceduresDrainage Test Chosen chart of simple duct Note1Pa/m=0.1mmAg/m Indoor Unit Installation of air suction and discharging ductRefrigerant pipe Examples of improper installationDimension of outdoor unit Outdoor Unit Selecting the installation place WarningInstalltion space Delivery of outdoor unitOutdoor Unit Mounting outdoor unit Connection of refrigerant pipe Outdoor Unit Connection of refrigerant pipe WarningDuring welding of the distribution pipe Outdoor unit pipelines connectionCheck if the pressure decrease Outdoor Unit Leak TestCheck for leakage Indoor unit Outdoor unit Outdoor Unit Pipe VacuumizingCalculation of the the refrigerant charge Outdoor Unit Refrigerant chargeRefill refrigerant Open all valvesPrecautions for Electrical wiring Electrical WiringSelection of size of power supply and interconnecting wires Wiring connectionPage Haier Group

AU84NATEAA, AD842AHEAA specifications

The Haier AD842AHEAA and AU84NATEAA are two innovative air conditioning models designed to enhance indoor comfort while optimizing energy efficiency. These units are well-regarded for their advanced technologies and user-friendly features, making them ideal choices for both residential and light commercial applications.

One of the standout features of the Haier AD842AHEAA is its Inverter Technology. This technology allows the compressor to adjust its speed according to the cooling demand, resulting in significant energy savings compared to traditional air conditioning systems. It ensures a more stable temperature and reduces noise levels, providing a peaceful environment.

The AU84NATEAA, on the other hand, showcases Haier's commitment to smart comfort solutions with its integrated Wi-Fi capabilities. Users can control the unit remotely via a smartphone app, enabling them to adjust settings, monitor energy usage, and receive maintenance alerts, contributing to a smarter and more convenient lifestyle.

Both models come equipped with an intelligent air flow system. This technology helps in distributing cool air evenly throughout the room, ensuring that no spot is left untouched. The air distribution design minimizes hot or cold pockets, promoting overall comfort and satisfaction for users.

Additionally, both units feature an energy-efficient design that is compliant with international energy standards. They utilize eco-friendly refrigerants, which not only help in reducing the carbon footprint but also provide reliable cooling performance without compromising environmental safety.

The Haier AD842AHEAA and AU84NATEAA are designed for easy installation and maintenance, boasting a streamlined user interface and accessible components for service. This focus on practicality and ease of use extends to their sleek and modern aesthetic, allowing them to blend seamlessly into any interior décor while functioning efficiently.

In summary, the Haier AD842AHEAA and AU84NATEAA air conditioning units represent a harmonious blend of advanced technology, comfort, and energy efficiency. With features like Inverter Technology, smart home integration, intelligent airflow, and eco-friendly refrigerants, these models stand out in the competitive air conditioning market, offering consumers modern solutions to their cooling needs. Whether for home use or in small business environments, these units provide a reliable and effective way to maintain ideal indoor conditions.