Haier AB362ACEAA Installation of Water Drainage Pipe, Pipe Tighten Amm Flare shape Size Torque

Page 25
Large size seal pad 10
(accessory)
4mm below below500
Table 1

Installation Procedure

5. REFRIGERANT PIPING (As for outdoor piping, please refer to installation Manual of outdoor unit.)

Outdoor is precharged with refrigerant.

Be sure to see the Fig.1, when connecting and removing piping from unit.

For the size of the flare nut, please refer to Table 1.

Apply refrigerant oil at both inside and outsid of lflare nut. Tighten it band tight 3-4 turns then tighten it.

Use torque specified in Table 1. (Too much force may damage flare nut, causing gas leakage).

Check piping joints for gas leakage. Insulate piping as shown in Fig. below. Cover joint of gas piping and insulator 7 with seal.

Apple refrigerant oil

Torque spanner

spanner

Piping joing

Flare nut

Medium size seal pad 11 (accessory)

(Cover the piping joint with seal pad.)

Clamp 3

Insulator (accessory) 8 (For liquid pipe)

Insulator (accessory) 7 Gas pipe (For gas pipe)

Liquid pipe

Pipe

Tighten

A(mm)

 

Flare shape

size

torque

 

 

 

 

 

6.35

1420~1720N.cm

8.3~8.7

 

 

 

 

(144~176kgf.cm)

 

 

 

9.52

3270~3990N.cm

12.0~12.4

 

2

R0.4 ~ 0.8

 

(333~407kgf.cm)

0.5

 

6180~7540N.cm

 

45

A

 

18.6~19.0

 

 

15.88 (630~770kgf.cm)

90

 

19.05

9720~11860N.cm

22.9~23.3

 

 

 

(990~1210kgf.cm)

 

 

 

6. INSTALLATION OF WATER DRAINAGE PIPE

(1) Install water drainage pipe

Pipe dia, shall be equal or larger than that of unit piping.(pipe of polyethylent; size: 25mm; O.D:32mm)

Drain pipe should be short, with a downward slope at least 1/100 to prevent air bag from happening.

If downward slope can't be made, take other measures to lift it up.

Keep a distance of 1-1.5m between suspending brackets, to make water hose straight.

1-1.5m

Slope over 1/100

Use the self-provided stiff pipe and clamp 1 with unit. Insert water pipe into water plug until it reaches the white tape. Tighten the clip until head of the screw is less than 4mm from hose.

Wind the drain hose to the clip using seal pad 9 . Insulate drain hose in the room.

Tape (White)

Clamp

Clamp (accessory)

Self-provided stiff pipe

<Cautions for the drain water lifting pipe>

Installation height shall be less than 280mm.

There should be a right angle with unit, 300mm from unit.

Drain hose (accessory)

(Note)

300mm below 1~1.5m

Suspending bracket

 

280220below

500below

drain water lifting pipe

 

Clamp (accessory)

Self-provided stiff pipe

(accessory) below75

The slope of water drain hose (1) shall be within 75mm, don't apply too much force on it. If several water hoses join together, do as per following proceedures.

Over 100

Connect water hoses with a T joint.

Specifieations of the water hoses shall meet the requirements for the unit running.

23

Image 25
Contents No.0010577963 Operation & Installation ManualContents Disposal of the old air conditioner Refrigerating circuit is leak-proof Applicable ambient temperature range For EAA seriesMachine is adaptive in following situation For ERA seriesSafety cautions Dont dismantle the outlet of the outdoor unit Location WiringOperating noise For series 142 Introduction to Spare PartsSuction grill Drain Hose Swing fenderClean the unit MaintenanceClean the air filter Clean indoor outdoor unitClean Install air filterFor series 242 Open inlet grillInstall inlet grill Take off air-filter Take of inlet grill CleanInstall swing plate Close inlet grillOpen Instruction Pre-season Care Seasonal Reserve Post-season CareFollowings are not malfuncition Trouble ShootingOFF Cooled air blown out when heating When Trouble HappensInsufficient cooling or heating Insufficient coolingRemarks SeriesError display For EAA series Customer Need-to-know Using DirectionsCustomer Need-to-know Meanings of Warning and Cautions Installation Procedure Selection of Installation Place Before Installation Dont discard any accessories until comp Installation example Preparation for the InstallationAfter installation on the ceiling Installation of Indoor UnitCase of new ceiling Case of ceiling already existsPipe Tighten Amm Flare shape Size Torque Installation of Water Drainage PipeAB182ACEAA For seriesWhen wiring is not complete After wiringWiring Example WiringInstallation of Ornament Panel Mounting on high ceiling Installation of inlet grill and cover plate Haier Group