Installation Procedure

CAUTIONS:

To ensure proper installation,read"Cautions" carefully before working.After installation,start the unit correctly and show customers how to operate and maintain the unit.

Meanings of Warning and Cautions:

Warning! Serious injury or even death might happen,if it is not observed.

Caution! Injury to people of damages to machine might happen, if it is not observed.

WARNING!

Installation shall be done by professional people, don't install unit by yourself. Incorrect installation will cause water leakage, electric shock or fire.

Install unit as per the Manual. Incorrect installation will cause water leakage, electric shock or fire accident.

Be sure to use specified accessaries and parts. Otherwise, water leakage, electric shock, fire accident or unit falling down may happen.

Unit should be placed on a place strong enough to hold the unit. Or, unit will fall down causing injuries.

When install the unit, take in consideration of storms, typhoom, earthquake. Incorrect installation may cause unit to fall down.

All electric work shall be done by experienced people as per eocal code, regulations and this Manual.

Use exclusive wire for the unit. Incorrect installation or undersized electric wire may cause electric shock or fire accident.

All the wires and circuit shall be safe. Use exclusive wire firmly fixed. Be sure that external force will not affect terminal bolck and electric wire. Poor contact and installation may cause fire accident.

Arrange wire correctly when connectin indoor and outdoor power supply. Fix terminal cover firmly to avoid overheat, electric shock or even fire accident.

In case retrigerant leakage occurred during unit installation, keep a good ventilation in the room.

Poisonous gas will occur when meet with fire.

Check the unit upon installation. Be sure there is no leakage. Refrigerant will induce poisonous gas when meet heat source as heater, oven, etc.

Cut power supply before touching terminal bolck.

CAUTION!

Unit shall be grounded. But grounding shall not be connected to gas pipe water pipe,

 

telephone line. Poor grounding will cause electric shock.

Earthing

Be sure to install a leakage breaker to avoid electric shock.

 

Arrange water drainage according to this Manual. Cover pipe with insulation materials in case dew may occur. Unproper installation of water drainage will cause water leakage and wet your furniture.

To maintain good picture or reduce noise, keep at least 1 m from T.V. radio, when install indoor and outdoor unit, connecting wire and power cable. (If the radio wave is relatively strong, 1 m is not enough to reduce noise).

Don't install unit in following places:

(a)Oil mist or oil gas exists, such as kitchen, or, plastic parts may get aged, or water leakage.

(b)Where there is corrosive gas. Copper tube and welded part may be damaged due to corrosion,causing leakage.

(c)Where there is strong radiation. This will affect unit's control system, causing malfunction of the unit.

(d)Where flamable gas, dirt, and volatile matter (thinner, gasoline) exist, These mattermight cause fire accident.

Refer to paper pattern when installing unit.

Cautions for the installation personnel

Don't fail to show customers how to operate unit.

15

Image 17
Contents Cassette Type AIR Conditioner Contents Disposal of the old air conditioner Model Machine is adaptive in following situationSafety cautions No inflammable spray fluid Dont dismantle the outlet of the outdoor unitWiring Please call dealer to install the air-conditionerLocation Operating noiseSuction grill Air filter Introduction to Spare PartsAir ourlet blade Clean outlet and shell MaintenanceClean air filter Pre-season Care Seasonal ReservePost-season Care Hua Trouble ShootingFollowings are not malfunction Unit fails to start Insufficient cooling When Trouble HappensInsufficient cooling or heating PCB flash times Failure code listHigh pressure malfunction Low pressure malfunctionCustomer Need-to-know Using DirectionsCustomer Need-to-know Installation tools Installation ProcedureMeanings of Warning and Cautions Unitmm Selection of installation placeHBU-28CH03 Preparation for the installation690 HBU-36HH03 HBU-42CH03 HBU-42CI03 HBU-42HI03 HBU-48CH03Installation example Installation of indoor unitAfter installation on the ceiling Fix the paper pattern Installation of water drainage pipe Wiring diagram After wiringWhen wiring is not complete Remove air inlet grill from ornament panel Connecting of unit Take HBU-28HH03 For examplePrepare ornament panel Handling of ornament panel Mounting on high ceiling Install ornament panel on indoor unitInstallation of inlet grill

HBU-42CI03, HBU-28CH03, HBU-28HH03, HBU-48CH03, HBU-36HH03 specifications

Haier has cemented its position as a leader in the HVAC industry with its innovative and high-performing products. Among its flagship offerings are the Haier HBU-48CK03, HBU-28CH03, HBU-48CH03, HBU-42CH03, and HBU-28HH03 models. Each of these units incorporates advanced technologies and features designed to meet varying demands in both commercial and residential settings.

The HBU-48CK03 stands out with a powerful cooling capacity of 48,000 BTUs, making it ideal for larger spaces. This model excels in energy efficiency, boasting a high EER rating, which means significant savings on electricity bills. The HBU-48CK03 is equipped with Smart Fan Technology that automatically adjusts fan speed based on cooling load, ensuring optimal comfort while minimizing noise levels.

Moving on to the HBU-28CH03, this model caters to smaller spaces with a cooling capacity of 28,000 BTUs. It incorporates a compact design, making it suitable for apartments and smaller commercial areas. The inverter technology in this unit ensures consistent temperature control and significantly reduces energy consumption. With multiple operating modes including cooling, heating, dehumidification, and fan-only, versatility is a key feature of the HBU-28CH03.

The HBU-48CH03 is another robust option featuring a balance of power and efficiency. With a similar capacity to the HBU-48CK03, it includes enhanced airflow design, allowing for better air distribution throughout the room. The model also features a self-diagnostic function, simplifying maintenance and troubleshooting.

The HBU-42CH03 offers a middle ground with a cooling capacity of 42,000 BTUs. This model is equipped with advanced filtration systems that improve indoor air quality by reducing allergens and pollutants. Its quiet operation technology ensures that the unit runs silently, making it perfect for environments where noise is a concern.

Lastly, the HBU-28HH03 is tailored for those who prioritize heating as much as cooling. This unit combines heat pump technology with efficient cooling capabilities, making it suitable for year-round use. The high-performance compressor enhances system reliability and longevity.

All these models showcase Haier’s commitment to developing HVAC solutions that not only provide comfort but also focus on energy efficiency and user convenience. With features like remote control, programmable timers, and comprehensive warranties, Haier offers great value for homeowners and business operators alike.