Installation Procedure

4. INSTALLATION OF INDOOR UNIT

In the case of new ceiling

(1) Install unit temporarily

Put suspending bracket on the suspending bolt. Be sure to use nut and washer at both ends of the bracket.

(2) As for the dimensions of ceiling hole, see paper pattern. Ask your real estate dealer for details.

Center of the hole is marked on the paper pattern.

Center of the unit is marked on the card in the unit and on the paper pattern.

Mount paper pattern 5 onto unit using 3 screws 6 . Fix the corner of the drain pan at piping outlet.

< After installation on the ceiling >

(3)Adjust unit to its right position. (Refer to preparation for the installation-(1))

(4)Check unit's horizontal level.

Watert pump and flating switch is installed inside indoor unit, check four corners of the unit for its level using horizontal compartor or PVC tube with water. (If unit is tilting against the direction of water drainage,

problem may occur on floating switch, causing water leakage.)

(5)Remove the washer mounlting 2 , and tighten the nut above.

(6)Remove the paper pattern.

In the case of ceiling already exists

(1)Install unit temporarily

Put suspending bracket on the suspending bolt. Be sure to use nut and washer at both ends of the bracket. Fix the bracket firmly.

(2)Adjust the height and position of the unit.

(Refer to preparation for the installation (1) ).

(3) Proceed with 3 and 4 of "In the case of new ceiling".

Nut (Prepare in feild)

Washer (Prepared in feild)

Suspending bolts

Fasten (double nuts)

Level

 

Insert

 

Washer fixing pad

 

(prepared in feild)

 

[ secure the washer firmly]

Polythene pipe

 

Screws at the piping outlet is fixed at the corner

of drain pan.

 

Center of ceiling hole Paper pattern

Paper pattern 5

 

Screw

Screw

[Fix the paper pattern]

19

Image 21
Contents Cassette Type AIR Conditioner Contents Disposal of the old air conditioner Machine is adaptive in following situation SpecificationsSafety cautions Dont dismantle the outlet of the outdoor unit Wiring LocationOperating noise Introduction to Spare Parts Install air filter MaintenanceClean Open inlet grillInstall inlet grill Take off airfilter Take of inlet grill CleanInstall swing plate Close inlet grillSeasonal Reserve Post-season Care Followings are not malfuncition Trouble ShootingOFF Insufficient cooling or heating When Trouble HappensChange-over switch Customer Need-to-know Customer Need-to-knowInstallation tools Installation ProcedureMeanings of Warning and Cautions Selection of Installation Place Before InstallationPreparation for the Installation Case of new ceiling Installation of Indoor UnitPipe Tighten Amm Flare shape Size Torque Installation of Water Drainage PipeWiring Wiring ExampleInstallation of Ornament Panel Remote receiver Electrical box Emergency switch Haier Group