Cautions

All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner.

Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.

Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.

Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.

Specifications

The refrigerating circuit is leak-proof.

The machine is adaptive in following situation

1. Applicable ambient temperature range:

 

 

 

Rated

Maximum

Minimum

 

Indoor

DB C

27

32

18

Cooling

WB C

19

23

14

 

 

DB C

35

43

10

 

outdoor

 

WB C

24

26

6

 

 

Heating

Indoor

DB C

20

27

15

WB C

14.5

--

--

 

 

 

outdoor

DB C

7

24

-7

 

 

WB C

6

18

--

2.If the supply cord is damaged, it must be replaced by the manufacturer or its service agentor a similar qualified person.

3.If the fuse on PC board is broken please change it with the type of T 3.15A /250VAC.

4.The wiring method should be in line with the local wiring standard.

5.The power cable and connecting cable are self-provided. The requirement of the power cable:

Model

 

HBU-18CF03

H07RN-F

HBU-18HF03

3G 2.5mm2

 

 

 

The requirement of the connecting cable: H07RN-3G2.0mm2+2*0.75mm2.(ForHBU-18HF03);

H07RN-F3G2.0mm2.(ForHBU-18CF03)

6.The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts should be no less 3mm. Such means for disconnection must be incorporation in the fixed wiring.

7.The waste battery shall be disposed properly.

8.The indoor unit installation height is at least 2.5m.

2

Image 4
Contents Cassette Type AIR Conditioner Contents Disposal of the old air conditioner Specifications Machine is adaptive in following situationSafety cautions Dont dismantle the outlet of the outdoor unit Location WiringOperating noise Introduction to Spare Parts Maintenance Install air filterClean Open inlet grillTake off airfilter Take of inlet grill Clean Install inlet grillInstall swing plate Close inlet grillSeasonal Reserve Post-season Care Trouble Shooting Followings are not malfuncitionOFF When Trouble Happens Insufficient cooling or heatingChange-over switch Customer Need-to-know Customer Need-to-knowInstallation Procedure Installation toolsMeanings of Warning and Cautions Before Installation Selection of Installation PlacePreparation for the Installation Installation of Indoor Unit Case of new ceilingInstallation of Water Drainage Pipe Pipe Tighten Amm Flare shape Size TorqueWiring Example WiringInstallation of Ornament Panel Remote receiver Electrical box Emergency switch Haier Group