Haier HDU-42HF03/H Drain Piping, Installation of indoor unit, Adjusting to the levelness

Page 27

Installation Manual For Indoor Unit

4. Installation of indoor unit

M10 nut

Fix the indoor unit to the hanger bolts.

If required, it is possible to suspend the unit to the beam, etc. Directly by use of the bolts without using the hanger bolts.

Main unit

Note

Hanging bolt M10 washer

M10 spring washer

When the dimensions of main unit and ceiling holes does not match, it can be adjusted with the slot holes of hanging bracket.

Adjusting to the levelness

(a)Adjust the out-of levelness using a level or by the following method.

Make adjustment so that the relation between the lower surface of the unit proper and water level in the hose becomes as given below.

Piping side

Supply water

Water level

0~5 mm

PVC hose

(0~0.2")

 

Bring the piping side slightly lower.

(b)Unless the adjustment to the levelness is made properly, malfunctioning or failure of the float switch may occur.

5.Drain Piping

(a)Drain piping should always be in a downhill grade (1/50~1/100) and avoid riding across an elevation or making traps.

Good piping

Inproper piping

 

Suspension

1.5m ~ 2m

 

Avoid riding across an elevation

bolts

 

 

 

 

Air vent

Keep free from traps

 

 

 

Do not pipe under water

Heat

A downhill grade

 

 

insulation

of 1/100 or more

 

 

(b)When connecting the drain pipe to unit, pay suffcient attention not to apply excess force to the piping on the unit side. Also, fix the piping at a point as close as possible to the unit.

(c)For drain pipe, use hard PVC general purpose pipe VP-25(I.D.1") which can be purchased locally. When connecting, insert a PVC pipe end securely into the drain socket before tightening securely using the attached drain hose and clamp. Adhesive must not be used connection of the drain socket and drain hose (accessory).

 

Stage

Drain socket

difference Drain hose

part

Drain socket

 

VP 25 joint

 

Pipe cover(large)

 

(field purchased)

 

[for insulation]

 

Main unit

(accessory)

 

 

 

 

 

Drain hose

VP 25

 

Clamp (accessory)

(field purchased)

 

(accessory)

Adhesion

Pipe cover

 

Pipe cover(small)

 

[for insulation]

 

 

(field purchased)

 

[for insulation]

 

 

(accessory)

 

 

26

Image 27
Contents Duct Type AIR Conditioner Table of Contents Disposal of the old air conditioner Make sure the system is grounded Safety PrecautionsDo not wash the air conditioner with water Machine is adaptive in following situation Parts and Functions Parts and Functions Operation Buttons and display of the wire controllerAuto Cool Fan operation Auto RUN, COOL,HEAT and DRY Timer operation Timer ON-OFF Cooling, dehumidifying mode Heating mode This series changeover switch is set On 2.OFF 3.OFF 4.OFF Cooling is not sufficient MalfunctionUnit fails to start Cooling or heating is not sufficientMalfunction Followings are not malfunction Points to observe Care and MaintenanceHOT KEEPis operated in the following cases For Preparation of HeatingHot KeepFor inspection and maintenance Is The Unit Installed CorrectlyInstallation place When you change your address or the installation placeInstall wire controller Installation Manual For Wire ControllerWire size HintHint Safety precautions Installation Manual For Indoor UnitHeight of ceiling Choose installation placeHanger bolts installation Preparation before installationGood piping Installation of indoor unitAdjusting to the levelness Drain PipingInstallation of air suction and discharging duct ProceduresDrainage Test Air volume Chosen chart of simple ductExamples of improper installation Operation method of fan controller Rotate this switchR0.4~0.8 Refrigerant pipeWiring connection Installation Manual For Electric WiringHaier Group

HDU-42HF03/H specifications

The Haier HDU-42HF03/H is a remarkable addition to the world of cooling and heating solutions, designed to meet diverse climate control needs in residential and commercial settings. This sleek and efficient ducted air conditioning unit combines advanced technology with reliability, ensuring optimal comfort for users throughout the year.

One of the standout features of the HDU-42HF03/H is its impressive energy efficiency. With a high Energy Efficiency Ratio (EER) and Coefficient of Performance (COP), it minimizes energy consumption while maximizing cooling and heating output. This sustainability-centric design not only reduces electricity bills but also supports environmentally friendly practices.

The unit employs inverter technology, which allows for variable speed control of the compressor. This means that the air conditioner can adjust its cooling or heating power based on the room's temperature, maintaining a consistent environment without the constant on-off cycling of traditional systems. This translates to quieter operation and longer equipment lifespan, as it reduces wear and tear on the components.

Equipped with advanced air filtration technology, the HDU-42HF03/H helps improve indoor air quality by trapping dust, pollen, and other allergens. This is particularly beneficial for individuals with respiratory conditions or sensitivities. The unit is designed for easy maintenance, with accessible filters that can be cleaned or replaced as needed, ensuring optimal performance over time.

The Haier HDU-42HF03/H is also notable for its climate adaptability. It can efficiently operate in various ambient conditions, making it suitable for different geographical locations. Its robust build quality ensures that it can withstand the rigors of daily use.

In terms of features, the HDU-42HF03/H offers a user-friendly control interface, enabling easy temperature adjustments and mode selection. Smart home compatibility allows users to integrate the system into existing smart devices, providing enhanced control and convenience.

Overall, the Haier HDU-42HF03/H stands out as a reliable and efficient choice for those seeking a versatile air conditioning solution. With its blend of energy efficiency, advanced technology, and user-centric design, it is well-equipped to provide comfortable living and working environments year-round. Whether for cooling hot summers or efficiently heating during chilly winters, this unit is a commendable option for modern climate control needs.