Haier HSU-24HD0307, HSU-24HK0307, 0010554405B Fixing the indoor unit body, Other direction piping

Page 4

Indoor unit

1.Insert the drain hose into the dent of heat insulation materials of indoor unit.

2.Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them.

3.Coat the flaring seal face with refrigerant oil and connect pipes.

Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape

 

Heat insulation

 

material

 

signal wire

Lid for right piping

Drain hose

Lid for left piping

Lid for under piping

Indoor/outdoor

 

 

electric cable

Fix with adhesive tape

 

Piping

Change-for-fresh-air tube

Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape.

[Other direction piping]

Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according to the position of wall hole. When bending, be careful not to crash pipes.

Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulation of connecting part specially.

Fixing the indoor unit body

Hang surely the unit body onto the upper notches of the mounting plate. Move the body from side to side to verify its secure fixing.

In order to fix the body onto the mounting plate,hold up the body aslant from the underside and then put it down perpendicularly.

4.Connecting the indoor/outdoor Electric Cable

Removing the wiring cover

Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws.

When connecting the cable after installing the indoor unit

1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed.

2. Pull out the cable on the front side, and connect the cable making a loop.

When connecting the cable before installing the indoor unit

Insert the cable from the back side of the unit, then pull it out on the front side.

Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws.

Pull the cable slightly to make sure the cables have been properly inserted and tightened.

After the cable connection, never fail to fasten the connected cable with the wiring cover.

Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect.

4

Image 4
Contents Accessory parts No.0010554405BFixing of outdoor unit Indoor UnitWhen the mounting plate is fixed side bar and lintel Installation of the Indoor Unit Drawing of pipeIndoor unit Indoor unitWhen connecting the cable after installing the indoor unit When connecting the cable before installing the indoor unitFixing the indoor unit body Other direction pipingFor the units with Fresh air functionOutdoor unit Outdoor unitPurging Method Power Source Installation Check for Installation and Test RunCutting and Flaring Work of Piping On Drainage