Haier 0010554405B, HSU-24HK0307, HSU-24HD0307 Fixing of outdoor unit, Indoor Unit

Page 2

HSU-09C03/VA(ZXF)

HSU-12C03/VA(ZXF)

HSU-18C03/V(ZXF) HSU-12H03/VB(ZXF)

HSU-22C03/V(ZXF) HSU-22C03/V(ZF) HSU-22H03/V(ZF)

HSU-09H03/VA(ZXF)

HSU-12H03/VA(ZXF)

HSU-18H03/V(ZXF)

HSU-12H03/V(ZXF)

HSU-22H03/V(ZXF) HSU-24C03/V(ZXF)

 

 

 

 

 

 

 

 

HSU-24C03/V(ZF)HSU-24H03/V(ZF) HSU-24H03/V(ZXF)

 

 

 

 

 

 

 

 

 

 

HSU-24HK0307

 

 

 

 

 

 

 

 

 

 

HSU-24HD0307

 

 

280

 

 

 

256

 

 

 

319.5

140

415

140

 

140

500

140

 

113.5

583

113.5

 

 

 

 

 

 

 

 

Floor fixing dimensions

 

Floor fixing dimensions

 

Floor fixing dimensions

of the outdoor unit

 

of the outdoor unit

 

 

 

of the outdoor unit

(Unit:mm)

 

 

(Unit:mm)

 

 

 

 

 

 

(Unit:mm)

 

 

 

 

 

 

 

 

 

 

Fixing of outdoor unit

Fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizontally. When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails or wires in consideration of earthquake and strong wind.

If vibration may affect the house, fix the unit by attaching a vibration-proof mat.

Indoor Unit

Selection of Installation Place Outdoor Unit

Place, robust not causing vibration, where the body can be supported sufficiently.

Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the unit are not disturbed.

Place, possible to drain easily, where piping can be connected with the outdoor unit.

Place, where cold air can be spread in a room entirely.

Place, nearby a power receptacle, with enough space around. (Refer to drawings).

Place where the distance of more than lm from televisions, radios, wireless apparatuses and fluorescent lamps can be left.

In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened.

Place, which is less affected by rain or direct sunlight and is sufficiently ventilated.

Place, possible to bear the unit, where vibration and noise are not increased.

Place, where discharged wind and noise do not cause a nuisance to the neighbors.

Place, where a distance marked is available as illustrated in the above figure.

Power Source

Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate.

Install an exclusive branch circuit of the power.

A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.

Selection of pipe

To this unit, both liquid and gas pipes shall be insulated

 

 

For 09

 

For 12,18

 

For 22,24

 

 

 

 

as they become Iow temperature in operation.

 

 

 

 

Use optional parts for piping set or pipes covered with

 

 

 

 

 

 

 

Liquid pipe(

)

6.35mm(1/4")

 

6.35mm(1/4")

 

9.52mm(3/8")

equivalent insulation material.

 

 

 

 

 

 

 

 

 

 

Gas pipe(

)

9.52mm(3/8")

 

12.7mm(1/2")

 

15.88mm(5/8")

 

 

 

 

 

 

 

 

2

Image 2
Contents Accessory parts No.0010554405BFixing of outdoor unit Indoor UnitIndoor unit When the mounting plate is fixed side bar and lintelInstallation of the Indoor Unit Drawing of pipe Indoor unitFixing the indoor unit body When connecting the cable after installing the indoor unitWhen connecting the cable before installing the indoor unit Other direction pipingFor the units with Fresh air functionOutdoor unit Outdoor unitPurging Method Cutting and Flaring Work of Piping Power Source InstallationCheck for Installation and Test Run On Drainage