Dimensions

(Fig. 1)

Front View

 

 

Cutaway View

 

 

Bottom View

 

 

a1

 

 

d1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

E

 

 

 

 

 

 

b1

D

f1

C

 

 

e1

 

 

 

 

 

 

 

 

A

B

 

 

C1

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

Net

a1

b1

c1

d1

e1

f1

A Hot water outlet

Volume Weight

B Cold water inlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C Heating element

 

 

 

 

 

 

 

 

 

D Enamel tank

 

 

 

 

 

 

 

 

 

E Wall-mounting bracket

Remarks:the permitted error limit of above parameters is

10%.

 

Electric Circuit Diagram

 

MT

BT

L

 

EH

 

 

N

E

HL

 

L: Brown wire

 

 

N: Blue wire

 

E

MT:High temperature limiter

 

BT: Thermostat

 

 

HL: Heating indicator

 

 

EH: Heating element

 

 

E:Yellow/green wire

 

 

Operation Instructions

For the first use after installation, due to there's no water within the tank, first the city water inlet valve and any water outlet valve of the water heater must be opened. Close the water outlet valve when water flows out continuously from the showerhead or other outlets (the tank is full). Check connections are free of water leakage, and insert the power plug.

Turn the knob to set your desired water heating temperature, which can be stepless changed between cold water inlet temperature and 75 . In heating mode, heating lamp is lighted on. Normally the knob shall be positioned at highest temperature. This machine has a thermostat function, which automatically switches off the water heater when temperature reaches the setting value, and switch on again when water temperature decreases to certain value.

City water pressure 0.75 MPa will cause much water flowing out from safety valve pressure relief vent. This is due to too big water pressure. Please ask after-sales service for correction.

Attentions in Operation

1.To avoid causing machine troubles, do not connect power before tank is full of water.

2.Adjust a suitable temperature before use, for water temperature above 50 may burn your skin.

3.This product is closed water heater, which can supply hot water through pipe connection to several points like bathroom (bathtub, washbasin, showerhead) and kitchen.

4.Heating adjustment can be made flexibly all year round adapting to climate changes. In long-term out-of-use or maintenance, you can close city water pipe valve, open mixing valve, and move up safety valve handle to drain the tank. To avoid injury, before next use, it is suggested to first open hot water valve before switching on the water heater, exhausting gas possibly retained in the pipeline. In this case, no smoke or fire is permitted near the open valve. Carefully check and confirm all parts are in good condition.

5.Provided hot water quantity can meet use demand, temperature setting shall be possibly low. It can minimize heat dissipation, high-temperature corrosion and sedimentation, ensuring a longer service life.

6.Regularly ask servicemen to make safety inspection, remove sediment on heating elements, and check consumption of anode bar. Too much consumed anode bar shall be replaced.

Cleaning and Maintenance

Statement: This water heater shall only be repaired and maintained by qualified servicemen. Improper maintenance may cause severe injury or damage. Before opening or repairing water heater, please do pull out the power plug.

Note:Before asking for service, please refer to troubleshooting section to resolve easy problems.

External Cleaning: Disconnect power supply before cleaning. Gently wipe with wet cloth dipped with a little of mild detergent. Do not use gasoline or other solvents. Finally dry with dry cloth. Keep water heater dry. Do not use cleansers containing grinding agent (e.g. toothpaste), acids, chemical solvents (e.g. alcohol) or polishers to clean.

Image 4
Contents Little Sea-ox Pre-safe Expert Friendly HintsCleaning and Maintenance FeaturesPacking List Before UsageDimensions Electric Circuit DiagramRemarksthe permitted error limit of above parameters is 10% Operation InstructionsInstallation Safety PrecautionsSetting Environment ² Ò» ª ײ Ó ÎÚ ·Þ Ũ ËÅ µ µÄ ·Ø ½

FCD-JTHC80-E, FCD-JTHC50-E, FCD-JTHC40-E, FCD-JTHC60-E specifications

The Haier FCD-JTHC series of air conditioners is known for its innovative designs and advanced technologies, ensuring efficient cooling and comfort in various environments. Among the notable models in this series are the FCD-JTHC60-E, FCD-JTHC40-E, FCD-JTHC50-E, and FCD-JTHC80-E. Each model brings a unique set of features and characteristics that cater to different cooling needs.

The FCD-JTHC60-E boasts a robust cooling capacity, making it ideal for spacious areas. Its advanced inverter technology adjusts the compressor speed based on the room temperature, resulting in energy savings and consistent comfort. The model also features a sleek design with a user-friendly interface, allowing for easy control via remote or mobile connectivity. The incorporation of air purification technology ensures the indoor air quality remains high, trapping dust and allergens effectively.

Moving to the FCD-JTHC40-E, this compact model is perfect for smaller rooms or apartments. Despite its size, it does not compromise on performance. Similar to its counterpart, it employs inverter technology for energy efficiency. Additionally, it includes a silent mode feature, making it suitable for use during nighttime or in quiet environments. Its quick cooling function allows users to enjoy a comfortable atmosphere shortly after turning the unit on.

The FCD-JTHC50-E strikes a balance between the previous two models, offering versatility for medium-sized spaces. It also comes with smart features, including Wi-Fi connectivity that allows users to control their air conditioner from their smartphones. This model emphasizes energy efficiency and includes a programmable timer, enabling users to schedule cooling times according to their preferences.

Lastly, the FCD-JTHC80-E is designed for larger areas, ensuring optimal cooling power. This model integrates advanced technologies, including a high-density filter that enhances air quality by effectively capturing pollutants and harmful particles. The model’s energy-efficient operation helps reduce electricity costs while maintaining optimal comfort. The FCD-JTHC80-E is equipped with an intelligent temperature control system that adapts to changes in ambient conditions, enhancing user comfort.

In summary, the Haier FCD-JTHC series offers a range of air conditioning units equipped with advanced technologies. From energy-efficient inverter systems to air purification and smart home integration, each model serves distinct needs while ensuring exceptional performance and user comfort. Whether for small rooms or larger spaces, Haier’s commitment to innovation and quality is evident in this diverse product line.