The integrated air valves, have a common air inlet (1/4" NPT) port and two outlet ports A and B (1/4” Tube) toward the front of the unit. The exhaust is silenced with a muffler. Do not exceed 120 psi at the air inlet to the unit. Refer to your pump owner’s manual for the maximum air pressure limit of the pump.
BOutlet Port
Exhaust |
|
Muffler | Strain Relief |
| for Power |
Common | Supply LIne |
Air Inlet |
|
AOutlet Port
Failure to use the following recommended valve can cause damage to the unit and possible personal injury. Follow the pressure relief procedure in the pump manual before moving or servicing the pump.
The A and B outlet ports are to be connected to the A and B ports respectively on the Husky 205, or to the two air valve control ports located on the air motors of pumps larger than the Husky 205. On pumps larger than the Husky 205, a three way solenoid valve (Graco Part Number 115606 or equivalent) MUST be installed on the main air supply to the pump. This ensures that pressure is not generated by the pump when the controller is not operating. The same signal used to start the CycleFlo II controller can also control this valve.
7 309004