Graco 332339B important safety instructions Fire and Explosion Hazard

Page 3

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

• Use equipment only in well ventilated area.

• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).

• Keep work area free of debris, including solvent, rags and gasoline.

• Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present.

Ground all equipment in the work area. See Grounding instructions.

Use only grounded hoses.

• Hold gun firmly to side of grounded pail when triggering into pail. Do not use pail liners unless they are antistatic or conductive.

Stop operation immediately if static sparking occurs or you feel a shock, Do not use equipment until you identify and correct the problem.

Keep a working fire extinguisher in the work area.

SKIN INJECTION HAZARD

High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.

• Do not spray without tip guard and trigger guard installed.

Engage trigger lock when not spraying.

Do not point gun at anyone or at any part of the body.

• Do not put your hand over the spray tip.

Do not stop or deflect leaks with your hand, body, glove, or rag.

Follow the Pressure Relief Procedure when you stop spraying/dispensing and before cleaning, checking, or servicing equipment.

Tighten all fluid connections before operating the equipment.

Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.

332339B

3

Image 3
Contents Dosing Pumps Important Safety InstructionsModels ContentsFire and Explosion Hazard Moving Parts Hazard Pump Components ComponentDescription Outlet Manifold Tubing Connections Air ConnectionsPump Up Inlet Down Stroke Outlet ValveDown Outlet Valve Electrical Connection Fluid ConnectionsRepair Preventive Maintenance ScheduleDisassemble the Driver Driver RepairDriver Assembly Disassemble the Lower Lower RepairLower Pump Assembly Reassemble the Lower Upper Throat Assembly Reconnect the Lower to the Driver Reconnect the Lower to the DriverPart Description Pump AssemblyLower Pump Assembly Qty Coupler Pump Driver AssemblyDescription Kit Part No Kit Description Repair Kits, Related Manuals, and AccessoriesPump Model In. mm DimensionsDosing Pumps Technical DataGraco Information Graco Standard Warranty