Graco 308738C manual Technical Data, Sound Power Levels dBa, tested in accordance with ISO

Page 14
Technical Data

Technical Data

Category

Data

Ratio

Maximum fluid working pressure Maximum air input pressure Fluid flow at 60 cycles per minute Maximum pump operating temperature Wetted parts

10:1

62 bar (6.2 MPa, 900 psi)

6.2bar (0.62 MPa, 90 psi) 11 liters/min (3 gpm)

82_C (180_F)

Refer to manual 307044.

Sound Pressure Levels (dBa) (measured at 1 meter from unit)

 

Input Air Pressures at 15 cycles per minute

 

 

 

 

Air Motor

2.8 bar (0.28 MPa, 40 psi)

4.8 bar (0.48 MPa, 70 psi)

7 bar (0.7 MPa, 100 psi)

 

 

 

 

President

73.6 dB(A)

78.3 dB(A)

80.9 dB(A)

 

 

 

 

Sound Power Levels (dBa)

(tested in accordance with ISO 9614–2)

Input Air Pressures at 15 cycles per minute

Air Motor

2.8 bar (0.28 MPa, 40 psi)

4.8 bar (0.48 MPa, 70 psi)

7 bar (0.7 MPa, 100 psi)

President

87.4 dB(A)

92.1 dB(A)

94.6 dB(A)

14 308738

Image 14
Contents 10 1 Ratio Presidentr Pump Instructions - Parts ListPart No. 239326, Series A 308738CWarning Symbol Table of ContentsSymbols Caution Symbolcal attention INJECTION HAZARDMOVING PARTS HAZARD FIRE AND EXPLOSION HAZARD TOXIC FLUID HAZARDPrepare the Site InstallationPrepare the Operator Mounting the PumpInstallation Typical Installation6308738 F G E D C K Y H A J BSystem Accessories InstallationOperation Pressure Relief ProcedureStarting and Adjusting the Pump Flush the Pump Before First UseOperation Shutdown and Care of the PumpFlushing the Pump COMPONENT RUPTURE HAZARDSolution TroubleshootingProblem CauseReconnecting the Displacement Pump ServiceDisconnecting the Displacement Pump Part PartsPart No. 239326, Series A DescriptionMeasurement DimensionsDimension tested in accordance with ISO Technical DataSound Power Levels dBa 308738 Performance ChartTechnical Data cycles per minuteFOR GRACO CANADA CUSTOMERS The Graco Standard WarrantyGraco Information Sales Office Minneapolis