HeadsetUSA PAS 400 manual Input RF-RECEIVER Input

Page 18

INPUT 3

RF-RECEIVER INPUT

Outputs

LINE OUT

REC OUT

MONITOR SPEAKER

Indicators

Power On

Battery Charge Indicator Power Supplies

AC mains

Internal Battery

External Battery

Power Consumption

AC mains

External DC

DC Out for External Equipment 12 VDC

3, 6 or 9 VDC (user selectable)

Protection Class

Rechargeable Battery

Type

Rating

Battery Charging Circuit

Description

Charging Time

Run Time in Battery Mode

10 dB / 12 dB / 12 dB headroom

Unbalanced, 2 x RCA jacks (summed to mono)

-6 dBu

Transformer balanced

-26 dBu

Master volume for optional RF receivers (up to 4 Sennheiser Evolution Bodypacks, or 1 Sennheiser Evolution Diversity + 2 Sennheiser Evolution Bodypacks may be built in)

Electrically balanced (transformer balanced optional), XLR male connector

+6 dBu

Unbalanced, 2 x RCA jacks (dual mono)

-6 dBu

15 / 20 Watts rms continuous / max into 4 ,

¼in. phone jack

Adjustable output

4 minimum load impedance, short-circuit protected

Red LED

Green LED

230 Volt AC / 50 Hz

120 Volt AC / 60 Hz

100 Volt AC / 50-60 Hz

12VDC (rechargeable from built-in charger)

12- 16 VDC

160 VA max

6 Amps / 14 VDC

0.5A, short-circuit protected, standard barrel connector

0.5A, short-circuit protected, standard barrel connector

Class 1, grounded chassis

Leak-proof, lead, maintenance free

12 V / 7.2 Ah

From AC mains supply only: Constant current until fully charged then automatically switches to constant voltage trickle charge

For completely discharged battery:

10 hours to 100% capacity

6 hours to 90% capacity

With no external units connected to DC Out and no built-in RF receivers or Delay units operating:

13 hours for low-level music

18 freePORT PAS 400 Version 060328

Image 18
Contents Portable active loudspeaker freePORT Content Safety Instructions FreePORT PAS 400 Version FreePORT PAS Rear Panel ViewDeliverables Installation & Set-upSafety Precautions Operating ConditionsTripod or Pole Mounting Set UpPower / Mains Connection Wall or Ceiling MountingPower Switch Ground Lift SwitchPowering with a 12-16 Volt DC External or Auto Battery Fuses 3Power On Indicator Battery Charging Circuit & Loading IndicatorBattery Self-Discharge During Storage, at 77 F 25 C Connecting Signal Sources Deep Discharge Cut-Off CircuitInput 3 Input 1Input 2 RF Receiver InputLine OUT PDD 63 Delay UnitAudio and DC Outputs REC OUTOperation Rechargeable Battery -Description Battery Replacement and DisposalTone Controls Troubleshooting Problem Possible Cause Possible SolutionsPerformance Curves Product Specifications InputsInput RF-RECEIVER Input FreePORT PAS 400 Version 060328 Warranty Information