Genelec 1031A manual Vertical / horizontal mounting, Console top mounting, Overload indicators

Page 3

TREBLE TILT

CONTROL

 

 

 

 

 

TREBLE TILT

BASS TILT

 

 

 

 

 

dB

 

dB

 

BASS TILT

 

 

 

 

+2

 

0

ALL OFF

OFF

ON

-2

dB

ALL OFF

 

-4

 

-6

 

 

 

 

0

 

-2

 

 

 

+2

 

-2

 

-4

 

CONTROL

 

 

-4

 

4kHz

20kHz

20Hz

600Hz

 

 

MUTE

BASS ROLL-OFF

OFF

ON

MUTE

 

 

 

 

 

 

 

-2

 

 

 

 

 

 

 

 

-4

dB

 

 

 

 

CONTROL

 

 

-6

 

 

 

 

 

OFF

ON

--42

dB

 

 

BASS ROLL-OFF

 

 

 

 

 

 

 

 

 

 

-6

 

 

 

dB

 

 

 

 

-8

 

 

 

 

INPUT SENSITIVITY

dBu

 

 

0

SPL@1m. REFER TO

0

ALL OFF

 

 

--86

 

 

+6

+4 +2

INPUT SENSITIVITY

-2

 

 

 

 

 

 

REQUIRED FOR 100dB

-4

 

CONTROL

-6

 

-2

 

OPERATING MANUAL

 

 

 

 

-4 FOR MAXIMUM SPL.

20Hz

100Hz

INPUT SENSITIVITY

USING THE TONE CONTROLS

REFER TO THE OPERATING MANUAL FOR SUGGESTED TONE CONTROL SETTINGS.

FOR ACCURATE OPERATION ONLY ONE SWITCH IN EACH TONE CONTROL GROUP SHOULD BE ON AT A TIME.

FOR A FLAT FREE FIELD RESPONSE SET ALL TONE CONTROLS TO OFF.

CAL POSITION

ALL CONTROLS : OFF

INPUT SENSITIVITY : -6dBu

Speaker Mounting

Treble tilt

Bass tilt

Bass roll-off

Position

 

 

 

Flat anechoic response

None

None

None

Free standing in a damped room

None

-2 dB

None

Free standing in a

None

-4 dB

-2 dB

reverberant room

 

 

 

Near field or console bridge

None

-4 dB

-4 dB

In a corner

None

-4 dB

-4 dB

INPUT

CONNECTOR

MAINS VOLTAGE SELECTOR (WHERE

APPLICABLE) MAINS CONNECTOR

MAINS SWITCH

2

PIN 1 = GROUND

3 PIN 2 = + INPUT PIN 3 = - INPUT

1

SIGNAL INPUT

MAINS

VOLTAGE

SELECTOR

MAINS INPUT

50 / 60 Hz

150 Watts

115 / 230 V ˜

ON

WARNING

GENELECR

1031A BI-AMPLIFIED MONITORING SYSTEM

MAGNETICALLY SHIELDED

fMADE IN FINLAND

SERIAL

NUMBER

ELECTRIC SHOCK HAZARD!

Table 1. Suggested tone control settings in some typical situations

mm

 

495

Cable

 

IT IS FORBIDDEN TO UNDO ANY SCREWS ON THIS EQUIPMENT. SERVICING AND ADJUSTMENT

MUST ONLY BE CARRIED OUT BY QUALIFIED SERVICE PERSONNEL.

NEVER OPERATE THIS EQUIPMENT WITHOUT A PROPER EARTHED MAINS CONNECTION.

DISCONNECT THE MAINS INPUT BEFORE REPLACING THE FUSE.

ENSURE THAT THE CORRECT VOLTAGE AND APPROPRIATE FUSE ARE SELECTED BEFORE

CONNECTING TO THE MAINS SUPPLY.

THIS EQUIPMENT IS CAPABLE OF PRODUCING SOUND PRESSURE LEVELS IN EXCESS OF 85dB

WHICH MAY CAUSE PERMANENT HEARING DAMAGE.

Figure 1. Amplifier panel layout of the 1031A

 

RCA

Screen

XLR

 

 

290 mm

(Source)

 

(Speaker)

320 mm

 

 

 

Figure 2. Location of the acoustic axis

Figure 3. RCA to XLR cable

the three tone control switch groups ‘treble tilt’, ‘bass tilt’ and ‘bass roll-off’ on the rear panel of the amplifier. The factory settings for these controls are ‘All Off’ to give a flat anechoic response. See Table 1 for sug- gested tone control settings. Figure 5 shows the effect of the controls on the anechoic response. Always start adjustment by setting all switches to ‘OFF’ position. Then set only one switch to the ’ON’ position to select the response curve needed. If more than one switch is set to ‘ON’ (within one switch group) the attenuation value is not accurate.

Vertical / horizontal mounting

The speakers are normally delivered set up for vertical mounting. Horizontal mount- ing should be avoided due to the increased likelihood of early reflections that degrade the the direct sound. If horizontal mounting is needed the DCW plate may be rotated so that the Genelec logo remains horizontal by removing the four corner screws of the DCW and carefully lifting and turning the DCW.

Console top mounting

If the 1031A’s are used for near field monitor- ing, avoid mounting them on the meter bridge of the console. Instead position the speakers slightly behind the console by using floor stands or wall mounts. This prevents the first reflections from the console surface from coloring the sound.

Overload indicators

The speaker is provided with two status LED's marked 'OVL' and 'ON'. The green ON-LED when lit indicates that the speaker is ready for use. The red OVL-LED indicates that the amplifier is overloaded or the driver protection circuit is activated. In both cases reduce the signal level so that the LED stops blinking. If the OVL-LED stays on constantly it indicates that the amplifier thermal protection is activated. Let the amplifier cool down and check that the ventilation at the rear side of the speaker is not blocked. There should be a clearance of more than 4" (10cm) between speaker rear and any solid surface.

Maintenance

No user serviceable parts are to be found within the amplifier unit. Any maintenance or repair of the 1031A unit should only be undertaken by qualified service personnel.

Safety considerations

Although the 1031A has been designed in accordance with international safety standards, to ensure safe operation and to maintain the instrument under safe operating conditions, the following warnings and cau- tions must be observed:

1.Servicing and adjustment must only be performed by qualified service personnel. The amplifier’s rear panel must

not be opened.

2.Do not use this product with an unearthed mains cable as this may lead to personal injury.

3.To prevent fire or electric shock, do not

expose the unit to water or moisture. Do not place any objects filled with liquid, such as vases on the speaker or near it.

4.Note that the amplifier is not completely disconnected from the AC

mains service unless the mains power cord is removed from the amplifier or the mains outlet.

WARNING!

This equipment is capable of producing sound pressure levels in excess of 85 dB, which may cause permanent hearing damage.

Accessories

 

Order code

Protective grille

1031-409

Wall mount

1031-404-V/H*

Floor stand

1031-405-V/H*

*State the desired speaker orientation V=vertical or H=horizontal when ordering these accessories.

Guarantee

This product is supplied with one year guar- antee against manufacturing faults or defects that might alter the performance of the 1031A unit. Refer to supplier for full sales and guar- antee terms.

Image 3
Contents Operating Manual Genelec 1031AMonitoring System Genelec 1031A Monitoring System Accessories Overload indicatorsMaintenance Safety considerationsCCIF-IM 1031A Operating ManualTHD SMPTE-IM