Goodman Mfg goodman High-Efficiency, 2- to 5-Ton Split System Air Conditioner Specifications

Page 3

Product Specifications

Specifications

 

SSX16

SSX16

SSX16

SSX16

SSX16

SSX16

 

0241B*

0301A*

0361B*

0421A*

0481B*

0591A*

 

 

 

 

 

 

 

Cooling Capacity

 

 

 

 

 

 

Nominal Cooling (BTU/h)

24,000

30,000

36,000

42,000

48,000

60,000

Decibels

73.5

73.5

73.5

75

74

73.5

 

 

 

 

 

 

 

Compressor

 

 

 

 

 

 

RLA

13.5

12.8

14.1

16.7

19.9

25.0

LRA

58.3

64

77

79

109

134

 

 

 

 

 

 

 

Condenser Fan Motor

 

 

 

 

 

 

Horsepower (RPM)

1/6

1/6

1/6

1/4

1/4

1/4

FLA

1.10

1.10

1.10

1.50

1.50

1.50

 

 

 

 

 

 

 

Refrigeration System

 

 

 

 

 

 

Refrigerant Line Size¹

 

 

 

 

 

 

Liquid Line Size (“O.D.)

⅜"

⅜"

⅜"

⅜"

⅜"

⅜"

Suction Line Size (“O.D.)

¾"

¾"

¾"

1⅛"

1⅛"

1⅛"

Refrigerant Connection Size

 

 

 

 

 

 

Liquid Valve Size (“O.D.)

⅜"

⅜"

⅜"

⅜"

⅜"

⅜"

Suction Valve Size (“O.D.)

¾"

¾"

¾"

⅞"

⅞"

⅞"

Valve Connection Type

Sweat

Sweat

Sweat

sweat

Sweat

Sweat

Refrigerant Charge

97

96

102

109

138

251

 

 

 

 

 

 

 

Electrical Data

 

 

 

 

 

 

Voltage-Phase

208/230-1

208/230-1

208/230-1

208/230-1

208/230-1

208/230-1

Minimum Circuit Ampacity ²

18.0

17.1

18.7

22.4

26.4

32.8

Max. Overcurrent Protection ³

30

25

30

35

45

50

Min / Max Volts

197/253

197/253

197/253

197/253

197/253

197/253

Electrical Conduit Size

½" or ¾"

½" or ¾"

½" or ¾"

½" or ¾"

½" or ¾"

½" or ¾"

 

 

 

 

 

 

 

Equipment Weight (lbs)

175

182

164

182

282

284

Ship Weight (lbs)

193

200

182

200

304

306

 

 

 

 

 

 

 

¹ Tested and rated in accordance with ARI Standard 210/240

²Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes ³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.

Notes

Always check the S&R plate for electrical data on the unit being installed.

Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.

Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.

Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECI-

FIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL.

SS-SSX16

www.goodmanmfg.com

3

Image 3
Contents SSX16 036 Brand Nomenclature½ or ¾ SpecificationsSweat 208/230-1Ata SSX160241B* / CA*F3636*6**+TXV+EEP 140 Expanded Cooling Data SSX160241B* / CA*F3636*6**+TXV+EEP23.4 356Ata SSX160301A* / CA*F3642*6C*+TXV +EEP 28.8 380159 Ata SSX160301A* / CA*F3642*6C* +TXV/MBVC1600 383 29.2Ata SSX160361B* / CA*F4860*6**+TXV+EEP 376 Expanded Cooling Data SSX160361B* / CA*F4860*6**+TXV+EEP34.4 12.0Ata SSX160421A* / CA*F4860*6B*+TXV +EEP 157 38.910.6 378Ata SSX160421A* / CA*F4860*6B*+TXV/MBVC2000 39.4 Ata SSX160481B* / CA*F4860*6D*+TXV 146 46.015.1 370Ata SSX160591A* / CA*F4961*6A*+TXV+EEP 160 Expanded Cooling Data SSX160591A* / CA*F4961*6A*+TXV+EEP56.5 18.254.0 Ata SSX160591A* / CA*F4961*6A*+TXV/MBVC200058.3 Unit Coils/Air Handlers Furnaces Total¹ Outdoor Indoor Units Cooling RatingsAhri Ratings CA*F3743*6D*+TXV VC80604B*B CA*F3642*6D*+TXV VM961005DXBCA*F3642*6D*+TXV E80805C*B CA*F3743*6D*+MBVC1600**-1A*+TXVCAPT3743*4A VC80805C*B CA*F3743*6D*+TXV VC950453BXBCAPT3743*4A VC80604B*B CAPT3743*4A VC81005C*BCHPF3642D6C*+MBVC2000**-1A*+TXV CHPF3743C6B*+MBVC1600**-1A*+TXVCHPF3743C6B*+MBVC2000**-1A*+TXV CA*F3636*6D E80603B*B ASPF426016E*+TXVAVPTC426014A CA*F3636*6D VC80604B*BCA*F3636*6D*+TXV VC80604B*B CA*F3636*6D*+MBVC1600**-1ACA*F3636*6D*+MBVC2000**-1A CA*F3636*6D*+MBVC2000**-1A*+TXVCA*F3642*6D ADVC80805C*B CA*F3642*6D VC80805C*BCA*F3642*6D E80603B*B CA*F3642*6D E80805C*BCA*F3743*6D GME951005DXA CA*F3743*6D VC80604B*BCA*F3743*6D VC81005C*B CA*F3743*6D E80603B*BCA*F4860*6D E80805C*B CA*F4860*6D E80603B*BCA*F4860*6D VC80805C*B CA*F4860*6D VC81005C*BCA*F4860*6D*+TXV VC91155DXA CA*F4860*6D*+MBVC1600**-1A*+TXVCA*F4860*6D*+MBVC2000**-1A CA*F4860*6D*+MBVC2000**-1A*+TXVCA*F4961*6D VM960604CXB CA*F4961*6D GME950603BXACA*F4961*6D GME950805CXA CA*F4961*6D E81005C*BCAPT3743*4A GME951005DXA CA*F4961*6D*+TXV VM961155DXBCA*F4961*6D*+TXV E80805C*B CA*F4961*6D*+TXV VM960604CXBCHPF3743C6B*+MBVC1600**-1A CHPF3743C6B VC950905CXBCHPF3743C6B VM960805CXB CHPF3743C6B VC950704CXBCHPF3743D6B*+MBVC2000**-1A CHPF3743D6B VM961005DXBCHPF3743D6B*+MBVC1600**-1A CHPF3743D6B*+MBVC1600**-1A*+TXVCHPF4860D6D*+MBVC2000**-1A CHPF4860D6D GME951005DXACHPF4860D6D*+MBVC1600**-1A CHPF4860D6D*+MBVC1600**-1A*+TXVCSCF3642N6D VM960604CXB CSCF3642N6D E80805C*BCSCF3642N6D GME950805CXA CSCF3642N6D VM960805CXBCSCF4860N6D VM961005DXB CSCF4860N6D VM960604CXBCSCF4860N6D VC950905DXB CSCF4860N6D VC951155DXB39,500 29,400 16.0 300 5622391 CA*F4961*6D*+TXV VC950915DXB CAPT4961*4A VC950704CXB CAPT4961*4A VC80805C*BCAPT4961*4A VC80604B*B CAPT4961*4A E80603B*BCHPF3743D6B*+EEP 300 5328403 440 5622478 45,500 34,600 15.5 300 5622550 400 5622596 400 5622599 330 5622631 56,500 39,000 15.5 570 5622711 Wiring Code Lvjb Accessories Dimensions

SS-SSX16, goodman High-Efficiency, 2- to 5-Ton Split System Air Conditioner specifications

Goodman Manufacturing has been a leading provider of heating and cooling systems, known for its commitment to efficiency, affordability, and innovation. Among its standout offerings is the Goodman High-Efficiency, 2- to 5-Ton Split System Air Conditioner, designated SS-SSX16. This air conditioning unit focuses on delivering exceptional performance while maintaining a keen eye on energy savings.

One of the main features of the SS-SSX16 is its high SEER (Seasonal Energy Efficiency Ratio) rating, which can reach up to 16. This means the unit is designed to deliver increased energy efficiency, providing homeowners with lower utility bills while effectively cooling their spaces. This energy efficiency is an important selling point, especially for those looking to reduce their environmental footprint.

The Goodman SS-SSX16 utilizes a two-stage compressor, which allows for enhanced efficiency and comfort. This design offers improved humidity control by operating at a lower speed for longer periods when the demand for cooling is low. This results in fewer temperature fluctuations and a more consistent indoor climate, promoting a comfortable living environment.

In terms of construction, the SS-SSX16 features a robust and durable design. It includes a heavy-gauge galvanized steel cabinet with a baked-on powder paint finish, ensuring longevity and resistance to the elements. The factory-installed filter drier protects the unit's internal components from moisture and debris, further enhancing reliability.

The SS-SSX16 is equipped with a number of advanced technologies that make installation and maintenance straightforward. The unit includes a silent, vibration-dampening compressor design, which helps minimize noise levels during operation. Additionally, the ComfortCloud monitoring system enables homeowners to monitor performance and troubleshoot issues right from their smartphones.

Goodman’s commitment to quality is underscored by its comprehensive warranty programs. The SS-SSX16 comes with a limited warranty on the compressor and parts, giving homeowners peace of mind regarding the long-term investment in their cooling system.

In summary, the Goodman High-Efficiency, 2- to 5-Ton Split System Air Conditioner SS-SSX16 is a robust solution for residential cooling needs. With its high efficiency, advanced technologies, and reliable construction, it stands out as a top choice for homeowners seeking comfort, efficiency, and cost savings in their HVAC systems.