Goodman Mfg goodman High-Efficiency, 2- to 5-Ton Split System Air Conditioner, SS-SSX16 dimensions

Page 35

Product Specifications

AHRI Ratings (cont.)

Outdoor

Indoor Units

 

 

Cooling Ratings

 

CFM

AHRI #

Unit

Coils/Air Handlers

Furnaces

Total¹

Sens.¹

SEER²

EER³

 

 

 

CHPF3743C6B*

A*VC950905CXB*

33,600

25,200

15.5

12.5

1,100

5622010

 

CHPF3743C6B*

G*VC950905CXB*

33,600

25,200

15.5

12.5

1,100

5622011

 

CHPF3743C6B*

G*VM960805CXB*

33,600

25,200

15.5

12.5

1,100

5622175

 

CHPF3743C6B*

G*VM960604CXB*

34,000

25,600

14.5

12.0

1,100

5622133

 

CHPF3743C6B*

G*VC950704CXB*

33,600

25,200

15.5

12.5

1,100

5621965

 

CHPF3743C6B*

A*VC950704CXB*

33,600

25,200

15.5

12.5

1,100

5621964

 

CHPF3743C6B*

A*VM960805CXB*

33,600

25,200

15.5

12.5

1,100

5622174

 

CHPF3743C6B*+EEP

 

34,000

25,600

14.5

12.0

1,100

5326909

 

CHPF3743C6B*+EEP+TXV

 

34,000

25,600

14.5

12.0

1,100

5325802

 

CHPF3743C6B*+MBVC1600**-1A*

 

33,600

25,200

16.0

13.0

1,100

5325803

 

CHPF3743C6B*+MBVC1600**-1A*+TXV

 

33,600

25,200

16.0

13.0

1,100

5325804

 

CHPF3743C6B*+MBVC2000**-1A*

 

34,000

25,600

16.0

13.0

1,100

5326910

 

CHPF3743C6B*+MBVC2000**-1A*+TXV

 

34,000

25,600

16.0

13.0

1,100

5325805

 

CHPF3743C6B*+TXV

G*E81005C*B*

33,600

25,200

15.5

12.5

1,150

5325846

 

CHPF3743C6B*+TXV

A*VC80805C*B*

33,600

25,200

15.5

12.5

1,100

5325888

 

CHPF3743C6B*+TXV

GME950603BXA*

33,600

25,200

14.5

12.0

1,150

5326258

 

CHPF3743C6B*+TXV

G*VC950704CXB*

33,600

25,200

15.5

12.5

1,100

5621967

 

CHPF3743C6B*+TXV

G*VC950905CXB*

33,600

25,200

15.5

12.5

1,100

5622013

 

CHPF3743C6B*+TXV

G*E80805C*B*

33,600

25,200

15.5

12.5

1,150

5325836

 

CHPF3743C6B*+TXV

G*VC80604B*B*

33,600

25,200

16.0

13.0

1,100

5325870

 

CHPF3743C6B*+TXV

A*VC81005C*B*

33,600

25,200

15.5

12.5

1,100

5325920

 

CHPF3743C6B*+TXV

G*E80603B*B*

33,600

25,200

15.1

12.5

1,150

5326293

 

CHPF3743C6B*+TXV

G*VC80805C*B*

33,600

25,200

15.5

12.5

1,100

5325889

 

CHPF3743C6B*+TXV

G*VC81005C*B*

33,600

25,200

15.5

12.5

1,100

5325921

 

CHPF3743C6B*+TXV

A*VC950905CXB*

33,600

25,200

15.5

12.5

1,100

5622012

SSX16

CHPF3743C6B*+TXV

A*VM960604CXB*

34,000

25,600

14.5

12.0

1,100

5622134

 

 

 

 

 

 

 

 

0361B*

CHPF3743C6B*+TXV

G*VM960604CXB*

34,000

25,600

14.5

12.0

1,100

5622135

(cont.)

CHPF3743C6B*+TXV

G*VM960805CXB*

33,600

25,200

15.5

12.5

1,100

5622177

 

CHPF3743C6B*+TXV

A*VC80604B*B*

33,600

25,200

16.0

13.0

1,100

5325869

 

CHPF3743C6B*+TXV

GME950805CXA*

33,600

25,200

14.5

12.0

1,150

5326268

 

CHPF3743C6B*+TXV

A*VC950704CXB*

33,600

25,200

15.5

12.5

1,100

5621966

 

CHPF3743C6B*+TXV

A*VM960805CXB*

33,600

25,200

15.5

12.5

1,100

5622176

 

CHPF3743D6B*

G*E80805C*B*

33,600

25,200

15.5

12.5

1,150

5325837

 

CHPF3743D6B*

G*E81005C*B*

33,600

25,200

15.5

12.5

1,150

5326301

 

CHPF3743D6B*

G*VC950704CXB*

33,600

25,200

15.5

12.5

1,100

5621969

 

CHPF3743D6B*

G*VC951155DXB*

34,000

25,600

15.5

12.5

1,100

5622094

 

CHPF3743D6B*

G*VM960604CXB*

34,000

25,600

14.5

12.0

1,100

5622137

 

CHPF3743D6B*

A*VC950704CXB*

33,600

25,200

15.5

12.5

1,100

5621968

 

CHPF3743D6B*

A*VC951155DXB*

34,000

25,600

15.5

12.5

1,100

5622093

 

CHPF3743D6B*

A*VM960604CXB*

34,000

25,600

14.5

12.0

1,100

5622136

 

CHPF3743D6B*

A*VM960805DXB*

33,600

25,200

15.5

12.5

1,100

5622216

 

CHPF3743D6B*

G*VC81005C*B*

33,600

25,200

15.5

12.5

1,100

5325923

 

CHPF3743D6B*

A*VC80805C*B*

33,800

25,400

15.5

12.5

1,100

5325890

 

CHPF3743D6B*

G*VC80805C*B*

33,800

25,400

15.5

12.5

1,100

5325891

 

CHPF3743D6B*

A*VC81005C*B*

33,600

25,200

15.5

12.5

1,100

5325922

 

CHPF3743D6B*

GME950805CXA*

33,600

25,200

14.5

12.0

1,150

5326269

 

CHPF3743D6B*

GME951005DXA*

33,600

25,200

15.5

12.5

1,150

5326284

 

CHPF3743D6B*

A*VC950905CXB*

33,600

25,200

15.5

12.5

1,100

5622014

 

CHPF3743D6B*

G*VM960805CXB*

33,600

25,200

15.5

12.5

1,100

5622179

 

CHPF3743D6B*

G*VM961155DXB*

34,000

25,600

15.5

12.5

1,100

5622293

 

CHPF3743D6B*

G*VC950905DXB*

33,600

25,200

15.5

12.5

1,100

5622053

 

CHPF3743D6B*

A*VM960805CXB*

33,600

25,200

15.5

12.5

1,100

5622178

 

CHPF3743D6B*

G*VM960805DXB*

33,600

25,200

15.5

12.5

1,100

5622217

See Notes on Page 53.

SS-SSX16

www.goodmanmfg.com

35

Image 35
Contents SSX16 036 Brand Nomenclature½ or ¾ SpecificationsSweat 208/230-1Ata SSX160241B* / CA*F3636*6**+TXV+EEP 140 Expanded Cooling Data SSX160241B* / CA*F3636*6**+TXV+EEP23.4 356Ata SSX160301A* / CA*F3642*6C*+TXV +EEP 159 28.8380 Ata SSX160301A* / CA*F3642*6C* +TXV/MBVC1600 383 29.2Ata SSX160361B* / CA*F4860*6**+TXV+EEP 376 Expanded Cooling Data SSX160361B* / CA*F4860*6**+TXV+EEP34.4 12.0Ata SSX160421A* / CA*F4860*6B*+TXV +EEP 157 38.910.6 378Ata SSX160421A* / CA*F4860*6B*+TXV/MBVC2000 39.4 Ata SSX160481B* / CA*F4860*6D*+TXV 146 46.015.1 370Ata SSX160591A* / CA*F4961*6A*+TXV+EEP 160 Expanded Cooling Data SSX160591A* / CA*F4961*6A*+TXV+EEP56.5 18.254.0 Ata SSX160591A* / CA*F4961*6A*+TXV/MBVC200058.3 Unit Coils/Air Handlers Furnaces Total¹ Outdoor Indoor Units Cooling RatingsAhri Ratings CA*F3743*6D*+TXV VC80604B*B CA*F3642*6D*+TXV VM961005DXBCA*F3642*6D*+TXV E80805C*B CA*F3743*6D*+MBVC1600**-1A*+TXVCAPT3743*4A VC80805C*B CA*F3743*6D*+TXV VC950453BXBCAPT3743*4A VC80604B*B CAPT3743*4A VC81005C*BCHPF3743C6B*+MBVC2000**-1A*+TXV CHPF3642D6C*+MBVC2000**-1A*+TXVCHPF3743C6B*+MBVC1600**-1A*+TXV CA*F3636*6D E80603B*B ASPF426016E*+TXVAVPTC426014A CA*F3636*6D VC80604B*BCA*F3636*6D*+TXV VC80604B*B CA*F3636*6D*+MBVC1600**-1ACA*F3636*6D*+MBVC2000**-1A CA*F3636*6D*+MBVC2000**-1A*+TXVCA*F3642*6D ADVC80805C*B CA*F3642*6D VC80805C*BCA*F3642*6D E80603B*B CA*F3642*6D E80805C*BCA*F3743*6D GME951005DXA CA*F3743*6D VC80604B*BCA*F3743*6D VC81005C*B CA*F3743*6D E80603B*BCA*F4860*6D E80805C*B CA*F4860*6D E80603B*BCA*F4860*6D VC80805C*B CA*F4860*6D VC81005C*BCA*F4860*6D*+TXV VC91155DXA CA*F4860*6D*+MBVC1600**-1A*+TXVCA*F4860*6D*+MBVC2000**-1A CA*F4860*6D*+MBVC2000**-1A*+TXVCA*F4961*6D VM960604CXB CA*F4961*6D GME950603BXACA*F4961*6D GME950805CXA CA*F4961*6D E81005C*BCAPT3743*4A GME951005DXA CA*F4961*6D*+TXV VM961155DXBCA*F4961*6D*+TXV E80805C*B CA*F4961*6D*+TXV VM960604CXBCHPF3743C6B*+MBVC1600**-1A CHPF3743C6B VC950905CXBCHPF3743C6B VM960805CXB CHPF3743C6B VC950704CXBCHPF3743D6B*+MBVC2000**-1A CHPF3743D6B VM961005DXBCHPF3743D6B*+MBVC1600**-1A CHPF3743D6B*+MBVC1600**-1A*+TXVCHPF4860D6D*+MBVC2000**-1A CHPF4860D6D GME951005DXACHPF4860D6D*+MBVC1600**-1A CHPF4860D6D*+MBVC1600**-1A*+TXVCSCF3642N6D VM960604CXB CSCF3642N6D E80805C*BCSCF3642N6D GME950805CXA CSCF3642N6D VM960805CXBCSCF4860N6D VM961005DXB CSCF4860N6D VM960604CXBCSCF4860N6D VC950905DXB CSCF4860N6D VC951155DXB39,500 29,400 16.0 300 5622391 CA*F4961*6D*+TXV VC950915DXB CAPT4961*4A VC950704CXB CAPT4961*4A VC80805C*BCAPT4961*4A VC80604B*B CAPT4961*4A E80603B*BCHPF3743D6B*+EEP 300 5328403 440 5622478 45,500 34,600 15.5 300 5622550 400 5622596 400 5622599 330 5622631 56,500 39,000 15.5 570 5622711 Wiring Code Lvjb Accessories Dimensions

SS-SSX16, goodman High-Efficiency, 2- to 5-Ton Split System Air Conditioner specifications

Goodman Manufacturing has been a leading provider of heating and cooling systems, known for its commitment to efficiency, affordability, and innovation. Among its standout offerings is the Goodman High-Efficiency, 2- to 5-Ton Split System Air Conditioner, designated SS-SSX16. This air conditioning unit focuses on delivering exceptional performance while maintaining a keen eye on energy savings.

One of the main features of the SS-SSX16 is its high SEER (Seasonal Energy Efficiency Ratio) rating, which can reach up to 16. This means the unit is designed to deliver increased energy efficiency, providing homeowners with lower utility bills while effectively cooling their spaces. This energy efficiency is an important selling point, especially for those looking to reduce their environmental footprint.

The Goodman SS-SSX16 utilizes a two-stage compressor, which allows for enhanced efficiency and comfort. This design offers improved humidity control by operating at a lower speed for longer periods when the demand for cooling is low. This results in fewer temperature fluctuations and a more consistent indoor climate, promoting a comfortable living environment.

In terms of construction, the SS-SSX16 features a robust and durable design. It includes a heavy-gauge galvanized steel cabinet with a baked-on powder paint finish, ensuring longevity and resistance to the elements. The factory-installed filter drier protects the unit's internal components from moisture and debris, further enhancing reliability.

The SS-SSX16 is equipped with a number of advanced technologies that make installation and maintenance straightforward. The unit includes a silent, vibration-dampening compressor design, which helps minimize noise levels during operation. Additionally, the ComfortCloud monitoring system enables homeowners to monitor performance and troubleshoot issues right from their smartphones.

Goodman’s commitment to quality is underscored by its comprehensive warranty programs. The SS-SSX16 comes with a limited warranty on the compressor and parts, giving homeowners peace of mind regarding the long-term investment in their cooling system.

In summary, the Goodman High-Efficiency, 2- to 5-Ton Split System Air Conditioner SS-SSX16 is a robust solution for residential cooling needs. With its high efficiency, advanced technologies, and reliable construction, it stands out as a top choice for homeowners seeking comfort, efficiency, and cost savings in their HVAC systems.