NW-A805/A806/A808/NWZ-A815/A816/A818
4-1-3. Standby current check
This mode is used in case standby current is checked.
Checking method:
1.Enter the test mode.
2.Press the v / V key to select the “POWER”, and press the B key to enter the minor item.
3.Press the v / V key to select the “DSVCHK”.
4.Press the u key, enter the state of the deep sleep.
5.Press the [BACK] key, release the state of the deep sleep.
liquid crystal display
POWER DSVCHK
OK
6. Press the [BACK] key, return to minor item selection screen.
4-1-4. Charge current check
This mode is used in case charge current is checked.
Checking method:
1.Enter the test mode.
2.Press the v / V key to select the “POWER”, and press the B key to enter the minor item.
3.Press the v / V key to select the “CHGCHK”.
4.Press the u key, the charge setting is displayed.
liquid crystal display
POWER CHGCHK
AC
AC
5.In this state, each time the [OPTION] key is pressed, the port setting for the charge is changed as shown in the table below.
|
| Port control |
|
Display CHG_XCHGEN CHG_PEN CHG_PEN2 | |||
AC | L | H | H |
USB500 | L | H | H |
USB100 | L | H | L |
4-1-5. Battery voltage check
This mode is used in case battery voltage is checked.
Checking method:
1.Enter the test mode.
2.Press the v / V key to select the “POWER”, and press the B key to enter the minor item.
3.Press the v / V key to select the “BATTCHK”.
4.Press the u key, the battery voltage is displayed.
When the battery voltage cannot be confirmed, “ERROR” is displayed.
liquid crystal display
POWER BATTCHK
X.XXXV
X.XXXV: Battery voltage
6. Press the [BACK] key, return to minor item selection screen.
4-2. Audio
While playing the audio track, it's in a repeat state. If [BACK] key is pressed, it’s stopped.
Press the [VOL +] key to switch the HP/LINE.
liquid crystal display
MPTAPP MENU
POWER
AUDIO OUTPUT
VIDEO SN
OTHER F1
SHUTDOWN F2
EXITTEST SEPLR
SEPRL
MAXOUT
NMLZR
SPCHK
6. Press the [BACK] key, return to minor item selection screen.
13