Goodman Mfg SS-CPC36-72 dimensions Wiring Diagram CPC036-72*3B Three Phase, Belt Drive

Page 32

Product Specifications

Wiring Diagram CPC036-72*3B (Three Phase, Belt Drive)

 

 

 

 

SMOKE/FIRE DETECTOR

 

RD

BK

 

 

 

 

REPLACES JUMPER

 

 

 

 

 

 

TB1

 

 

 

 

 

 

 

 

 

 

 

 

 

BR

 

1

2

3

 

 

RD

RD

 

BR S2

S1 C

208

240

 

 

GR

 

460

 

 

 

 

 

 

 

TR

575

 

 

G EBTDR

 

 

PK

 

 

BL

 

 

24V

 

 

R

K1

NO

 

 

 

 

 

 

 

 

 

BL

 

 

XFMR-R

 

 

GR

 

BL

 

 

 

COM

 

 

 

 

 

XFMR-C

K1

RD

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPEED

NOTE #2

NC

 

 

 

 

RD

 

M1

M2

 

 

 

 

OR

UP

PU

 

 

 

 

 

 

 

 

 

 

BL

 

 

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

 

BL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BR

 

 

 

 

 

 

 

 

 

2

 

 

BK

 

 

 

BK

0

 

 

 

 

 

8

BL

 

 

 

 

 

 

 

 

RD

RD

 

-

BL

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

RD

T3

L3

 

 

 

 

4

 

 

 

 

 

 

 

0

RD

T2

L2

 

 

 

 

-

 

 

 

 

4

YL

 

 

 

 

 

 

 

C

 

 

 

 

6

 

 

 

 

 

 

BK

T1

L1

 

SEE

 

0

BK

 

 

 

 

-

 

 

 

 

NOTE #2

5

 

 

 

 

 

 

 

BK

 

 

 

 

 

 

7

 

YL/PK

 

 

 

 

5

 

 

 

GND

 

/

 

 

 

 

3

 

 

PLF 2

 

 

 

 

 

 

YL

 

/

 

 

 

 

 

 

 

 

OR

 

 

 

 

6

 

 

GR

 

3

6

 

0

 

 

 

 

2

5

 

 

 

 

YL

 

1

4

 

 

 

 

PU

BL

 

 

YL

 

 

 

 

 

 

 

 

power death.

Multiple

injury, or

unit.

personal

 

 

 

RD

 

PU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WH

 

L1

L2

L3

 

 

 

 

 

 

 

 

GR

C

F

3

6

9

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

T1

T2

T3

RCCF

 

2

5

8

BR

 

 

 

 

 

 

 

BC

 

PU

 

 

 

 

 

 

 

 

1

4

7

 

 

 

 

 

 

 

 

RD

OR

 

 

PLF 1

 

BL

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PU

BK

 

 

 

 

 

 

 

 

BR

EM

CM

YL

BK

RD

T3 T1 T2

RD

GR

YL/PK

LPS

PU YL RD GR WH BR BL OR

TB1

LVJB

T

 

Y1

H

Y/Y2

E

R

R

G

M

O

W1

S

W2

T

C

A

O

T

++

 

CONTROL

BL/PK BOX

 

servicing or installing this

cause property damage,

before

so may

all power

Failureto do

COMPHPS

Disconnect present.

L1

 

 

L2

L3

 

 

SUPPLY VOLTAGE

 

 

 

 

208-240/3/60

 

 

 

 

T2 C

 

 

C

T1

T2

 

 

 

 

 

 

 

T1 COMP

C

 

 

 

T3

 

 

 

T3

 

 

C

RCCF

F

CM

 

 

BC

 

 

 

 

BC

 

 

 

 

 

 

 

EM

 

 

 

 

 

 

 

BC

 

 

 

 

 

 

 

208-240V

 

 

 

 

1

 

 

3

 

TB1

 

 

 

TR

 

 

 

 

 

 

 

 

 

EBTDR

24V

 

 

 

 

 

 

 

 

 

 

 

R

G

 

C

 

R

 

 

 

EBTDR

BC

 

 

 

 

 

 

 

 

EBTDR

 

 

 

 

 

 

LPS

 

 

 

 

 

 

C

P

 

 

 

HPS

 

4

 

 

 

 

6 5 4

L

 

 

 

 

 

F

5

 

 

 

PLF2

3 2 1

1

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

R W2 O

W1

Y

Y1 G

C

 

 

Y2

 

 

 

 

 

 

 

TB1

THERMOSTAT

++

SEE NOTE #3

 

 

COMPONENT LEGEND

BC

BLOWER CONTACTOR

C

CONTACTOR

CM

CONDENSER MOTOR

CMR

CONDENSER MOTOR RELAY

COMP

COMPRESSOR

DC

DEFROST CONTROL

DFT

DEFROST THERMOSTAT

ECON

ECONOMIZER

EBTD

ELECTRONIC BLOWER TIME DELAY

EMR

EVAPORATOR MOTOR RELAY

R

RELAY

EM

EVAPORATOR MOTOR

FC

FAN CAPACITOR

GND

EQUPIMENT GROUND

HPS

HIGH PRESSURE SWITCH

HVDR

HIGH VOLTAGE DEFROST RELAY

LPS

LOW PRESSURE SWITCH

LVDR

LOW VOLTAGE DEFROST RELAY

LVJB

LOW VOLTAGE JUNCTION BOX

PB

POWER DISTRUBTION BLOCK

PLF

FEMALE PLUG / CONNECTOR

RVC

REVERSING VAVLE COIL

RCCF

RUN CAPACITOR FOR

 

COMPRESSOR AND FAN

TB1

TERMINAL BLOCK (24V SIGNAL)

TR

TRANSFORMER

NOTES:

1.REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.

2.USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE

3.ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT, REMOVE MALE PLUG, ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY.

4.FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.

SEE UNIT RATING PLATE FOR TYPE AND SIZE

OF OVER CURRENT PROTECTION

208-240-460-575/3/60 0140L00427 REV. B

FACTORY WIRING

LINE VOLTAGE

LOW VOLTAGE

OPTIONAL

HIGH VOLTAGE

 

 

FIELD WIRING

 

 

HIGH VOLTAGE

 

 

LOW VOLTAGE

 

 

WIRE CODE

BK

BLACK

BL

BLUE

BR

BROWN

GR

GREEN

OR

ORANGE

PK

PINK

PU

PURPLE

RD

RED

WH

WHITE

YL

YELLOW

BL/PK

BLUE WITH PINK STRIP

YL/PK

YELLOW WITH PINK STRIP

THERMOSTAT

FIELD WIRING

NO ECONOMIZER

 

W

WH

W

G

GR

G

R

RD

R

Y1

 

 

Y/Y2

YL

Y

C

BL

C

O

OR

O

TB1

 

STAT

 

 

WITH ECONOMIZER OPTION

W

WH

W

G

GR

G

R

RD

R

Y1

YL

Y

Y/Y2

 

 

C

BL

C

O

OR

O

TB1

 

STAT

 

 

2 STAGE COOLING

 

W

WH

W

G

GR

G

R

RD

R

Y1

YL

Y1

Y/Y2

PK

Y2

C

BL

C

O

OR

O

TB1

 

STAT

 

 

High Voltage: sources may be

 

Warning

Always or the wiring.

change. diagram -to-date

Wiring is subject to refer to the wiring unit for the most up

32

www.goodmanmfg.com

SS-CPC36-72

Image 32
Contents Standard Features 35,000 71,000 BTU/hNomenclature ConfiguraonProduct Specifications CPC036 B Models Belt Drive Evap Fan Data Product Specifications CPC048 B ModelsCPC048 Product Specifications CPC060 B Models CPC060Product Specifications CPC072 B Models CPC072Heat Kit Electrical Data Blower Only, Heat Mode 3 Tons KW Correction Factor10 kW 15 kWHeat Kit Electrical Data Blower Only, Heat Mode 4 Tons BTU atHeat Kit Electrical Data Blower Only, Heat Mode 5 Tons Heat Kit Electrical Data Blower Only, Heat Mode 6 Tons BTU @Airflow Data CPC036 Direct Drive HorizontalDirect Drive Down Shot TapStandard Belt Drive Horizontal High-Static Belt Drive HorizontalStandard Belt Drive Down Shot High-Static Belt Drive Down ShotStandard Direct Drive Down Shot Airflow Data -CPC048Standard Direct Drive Horizontal Turns Standard Direct Drive Motor Down Shot Airflow Data CPC060Standard Direct Drive Motor Horizontal Turns Open Airflow Data CPC072 ESP In W.C Turns32.1 10.3345 131Expanded Cooling Data CPC036 34.610.6 36842.2 12.3373 135Expanded Cooling Data CPC048 45.512.7 398381 55.115.3 Expanded Cooling Data CPC060 59.515.9 407372 Airflow65.8 Expanded Cooling Data CPC072 LO PRDimensions Unit Clearances Electrical Entrance LocationsCorner & Center-of-Gravity Locations Roof Curb Installation RiggingUnit Weights Ton Top View for BA Models Roof Curb InstallationView for BA Models Wiring Diagram CPC036/48*1D Single Phase, Direct Drive Wiring Diagram CPC036/48*3D Three Phase, Direct Drive Wiring Diagram CPC036-72*3B Three Phase, Belt Drive Wiring Diagram CPC060*1D Single Phase, Direct Drive Wiring Diagram CPC036-72*4B/7B 460V/575v, Belt Drive Wiring Diagram CPC060*3D Single Phase, Direct Drive Accessories Item # Description Fits Model Sizes

SS-CPC36-72 specifications

The Goodman Manufacturing SS-CPC36-72 is a top-tier commercial rooftop unit designed for optimal heating and cooling in a variety of settings. This unit embodies the cutting-edge technology and engineering expertise that Goodman is known for. Ideal for medium to large commercial buildings, the SS-CPC36-72 stands out with its robust performance and energy efficiency.

One of the defining features of this unit is its high-efficiency scroll compressor, which significantly enhances energy savings while providing reliable performance. The compressor operates quietly and has fewer moving parts compared to traditional compressors, resulting in lower maintenance requirements. This feature is critical for environments where noise levels must be minimized.

Additionally, the Goodman SS-CPC36-72 is designed with a multi-stage cooling system. This technology allows the unit to operate at varying capacities, adapting to real-time cooling needs. This not only improves comfort levels in the space but also optimizes energy use, leading to reduced operational costs.

Another notable characteristic of this model is its environmentally friendly R-410A refrigerant. The use of this refrigerant contributes to lower global warming potential, aligning with modern sustainability goals. This makes the Goodman SS-CPC36-72 not just a powerful unit but also an environmentally conscious choice for businesses looking to reduce their carbon footprint.

The unit is built with durable materials, ensuring longevity and resilience in various weather conditions. From the corrosion-resistant cabinet to the high-quality insulation, every component is crafted to withstand the rigors of commercial environments. This durability translates to reduced replacement costs over time, making it a wise investment.

Ease of installation and maintenance is another hallmark of the Goodman SS-CPC36-72. The unit is designed with serviceability in mind, featuring accessible components that simplify routine checks and repairs. This means reduced downtime and enhanced productivity for businesses relying on consistent climate control.

In summary, the Goodman Mfg SS-CPC36-72 is a highly efficient and versatile rooftop HVAC unit. With its advanced compressor technology, environmentally friendly refrigerant, robust construction, and easy maintenance features, it is well-equipped to meet the demands of modern commercial spaces while delivering exceptional performance and reliability.