Machined parts coated with rust preventive should be restored to good condition promptly if signs of rust occur. Immediately remove the original rust preventive coating with petroleum solvent and clean with lint-free cloths. Polish any remaining rust from surface with crocus cloth or fine emery paper and oil. Do not destroy the continuity of the surfaces. Wipe clean thoroughly with Tectyl® 506 (Ashland Inc.) or the equivalent. For hard to reach internal surfaces or for occasional use, consider using Tectyl® 511M Rust Preventive or WD-40®or the equivalent.

Table of Contents

General Information

Receiving . . . . . . . . . . . . . . . . 2 Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Installation Recommendations

BCSW-FRP . . . . . . . . . . . . . . . . 4 Bases . . . . . . . . . . . . . . . . . . 5 Belt Guards . . . . . . . . . . . . . . . . 5 Drain Connections . . . . . . . . . . . . . . . . . . . . . . . . . 5 Ductwork / Stacks . . . . . . . . . . . . . 5 Rotatable Housing . . . . . . . . . . . . . . . . . . . . . . . . . 5 Radial gap, overlap & wheel alignment . . . . . . . . . 6

Flexible Couplings . . . . . . . . . . . . . . 7 V-Belt Drives . . . . . . . . . . . . . . . . 7 Unit Start-Up . . . . . . . . . . . . . . . . 8 Vibration . . . . . . . . . . . . . . . . . . 8 Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . 9-10

Motors . . . . . . . . . . . . . . . . . 9 Shaft Bearings . . . . . . . . . . . . . . 9 V-Belt Drive . . . . . . . . . . . . . . . 10 Unit Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Parts List . . . . . . . . . . . . . . . . . 10 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Maintenance Log . . . . . . . . . . . . . . . . . . . . Backcover Warranty . . . . . . . . . . . . . . Backcover

CAUTION

When installing a fan, ensure the proper protective devices are used to protect personnel from moving parts and other hazards. A complete

line of protective accessories are available from Greenheck including belt guards, shaft guards, and electrical disconnects.

Electrical Disconnects

All fan motors should have disconnects located in close visual proximity to turn off electrical service. Service disconnects shall be locked out when maintenance is being performed.

Moving Parts

All moving parts must have guards to protect personnel. Refer to local codes for requirements as to the number, type and design. Fully secure fan wheel before performing any maintenance. The fan wheel may start “free wheeling” even if all electrical power has been disconnected. Before the initial start-up or any restart, check the belt and shaft guards and the access doors to ensure that they are installed and secure.

Model BCSW-FRP 3

Image 3
Contents Model BCSW-FRP General Safety Information Installation, Operation and Maintenance ManualHandling Inspection & Maintenance during StorageReceiving UnpackingTable of Contents Ducted Inlet Installations InstallationDrain Connection Rotatable HousingsBases Foundation and Isolation Belt GuardsRadial Gap, Overlap and Wheel Alignment Belt Drive Installation Flexible Couplings Arr OnlyBelt Drives Common Sources of Vibration Unit Start-UpAdditional Steps for Initial Start-Up VibrationRoutine Maintenance MotorsShaft Bearings Parts List Unit IdentificationBelt Drives Problem Cause Corrective Action TroubleshootingMaintenance Log WarrantyDate Time AM/PM

474051 specifications

The Greenheck Fan 474051 is a high-performance, energy-efficient ventilation solution designed to meet the diverse needs of commercial and industrial applications. As a leader in the ventilation industry, Greenheck is known for its innovation and reliability, and the 474051 model exemplifies these qualities with its robust features and advanced technologies.

One of the standout characteristics of the Greenheck Fan 474051 is its powerful motor, which enables high airflow rates while maintaining low noise levels. This is particularly beneficial in environments where noise reduction is critical, such as schools, hospitals, and office buildings. The motor is designed with energy efficiency in mind, helping to reduce operational costs and lower the carbon footprint, aligning with the growing demand for sustainable technologies.

The 474051 fan also incorporates state-of-the-art blade design, which enhances airflow efficiency. The blades are engineered to provide optimal performance by minimizing turbulence and maximizing air movement. This results in improved overall system efficiency, ensuring that the fan can deliver the required air changes effectively without excessive energy consumption.

Another key feature of the Greenheck Fan 474051 is its modular construction, allowing for easy installation and maintenance. The fan is designed to be compatible with various mounting options, catering to the unique requirements of different spaces. Additionally, components are easily accessible for servicing, reducing downtime and enhancing reliability.

The fan is equipped with advanced control options that facilitate precise operation in response to varying ventilation demands. Users can take advantage of various control technologies, including variable speed drives, enabling them to adjust fan speed according to real-time conditions. This flexibility not only enhances comfort but also contributes to energy savings.

Furthermore, the 474051 model is built with durable materials and finishes, ensuring longevity and resilience in demanding environments. Its corrosion-resistant housings and components stand up to harsh conditions, making it suitable for applications in manufacturing, food processing, and chemical handling, among others.

In summary, the Greenheck Fan 474051 combines energy efficiency, advanced technology, and robust construction to provide superior ventilation solutions. Whether used in commercial or industrial settings, its features and capabilities make it a reliable choice for enhancing air quality while supporting sustainability initiatives.