Goodmans GPC1324H41A, GPC 13 SEER R-410A Cooling Performance Data 5MM Coils GPC1349H41AA

Page 41

 

MODEL: GPC1349H41A*

 

 

 

 

 

EXPANDED PERFORMANCE DATA

 

 

 

COOLING OPERATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

 

 

75

 

 

 

 

85

 

 

 

95

 

 

105

 

 

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Entering Indoor Wet

Bulb Temperature

 

 

 

 

 

 

 

 

 

 

IDB*

Airflow

 

59

 

63

 

67

71

59

63

 

67

71

59

63

 

67

71

59

63

 

67

71

59

63

67

71

59

63

67

71

 

 

 

MBh

44.6

 

46.2

 

50.6

-

43.5

45.1

 

49.5

-

42.5

44.1

 

48.3

-

41.5

43.0

 

47.1

-

39.4

40.8

44.7

-

36.5

37.8

41.4

-

 

 

 

S/T

0.77

 

0.64

0.44

-

0.79

0.66

 

0.46

-

0.81

0.68

0.47

-

0.84

0.70

0.49

-

0.87

0.73

0.50

-

0.88

0.73

0.51

-

 

 

 

Delta T

17

 

15

11

-

18

15

 

12

-

18

15

12

-

18

15

12

-

18

15

12

-

16

14

11

-

 

 

1800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

3.20

 

3.27

3.36

-

3.43

3.49

 

3.60

-

3.62

3.70

3.81

-

3.80

3.87

3.99

-

3.95

4.03

4.15

-

4.07

4.16

4.29

-

 

 

 

AMPS

13.9

 

14.2

14.5

-

14.8

15.1

 

15.5

-

15.9

16.2

16.6

-

16.8

17.1

17.6

-

17.7

18.0

18.5

-

18.5

18.9

19.5

-

 

 

 

HI PR

234

 

252

266

-

262

282

 

298

-

298

321

339

-

340

366

386

-

382

411

434

-

422

454

480

-

 

 

 

LO PR

112

 

119

130

-

118

125

 

137

-

123

130

142

-

129

137

149

-

135

143

157

-

139

148

162

-

 

 

 

MBh

43.3

 

44.9

49.2

-

42.3

43.8

 

48.0

-

41.3

42.8

46.9

-

40.3

41.7

45.7

-

38.3

39.6

43.4

-

35.4

36.7

40.2

-

 

 

 

S/T

0.73

 

0.61

0.42

-

0.76

0.63

 

0.44

-

0.78

0.65

0.45

-

0.80

0.67

0.46

-

0.83

0.69

0.48

-

0.84

0.70

0.49

-

 

 

 

Delta T

18

 

16

12

-

18

16

 

12

-

18

16

12

-

19

16

12

-

18

16

12

-

17

15

11

-

 

70

1600

KW

3.18

 

3.24

3.34

-

3.40

3.47

 

3.57

-

3.60

3.67

3.78

-

3.77

3.85

3.96

-

3.92

4.00

4.12

-

4.04

4.12

4.25

-

 

 

 

AMPS

13.8

 

14.1

14.4

-

14.7

15.0

 

15.4

-

15.7

16.0

16.5

-

16.6

17.0

17.4

-

17.5

17.9

18.4

-

18.4

18.8

19.3

-

 

 

 

HI PR

231

 

249

263

-

260

279

 

295

-

295

318

336

-

336

362

382

-

378

407

430

-

418

450

475

-

 

 

 

LO PR

110

 

118

128

-

117

124

 

136

-

121

129

141

-

127

136

148

-

134

142

155

-

138

147

160

-

 

 

 

MBh

40.0

 

41.4

45.4

-

39.0

40.4

 

44.3

-

38.1

39.5

43.3

-

37.2

38.5

42.2

-

35.3

36.6

40.1

-

32.7

33.9

37.1

-

 

 

 

S/T

0.70

 

0.59

0.41

-

0.73

0.61

 

0.42

-

0.75

0.63

0.43

-

0.77

0.65

0.45

-

0.80

0.67

0.46

-

0.81

0.68

0.47

-

 

 

1400

Delta T

18

 

16

12

-

19

16

 

12

-

19

16

12

-

19

16

12

-

19

16

12

-

17

15

11

-

 

 

KW

3.11

 

3.17

3.26

-

3.33

3.39

 

3.49

-

3.52

3.59

3.69

-

3.68

3.76

3.87

-

3.82

3.90

4.02

-

3.95

4.03

4.15

-

 

 

 

AMPS

13.5

 

13.8

14.1

-

14.4

14.7

 

15.0

-

15.4

15.7

16.1

-

16.2

16.6

17.0

-

17.1

17.5

18.0

-

18.0

18.3

18.9

-

 

 

 

HI PR

224

 

242

255

-

252

271

 

286

-

286

308

326

-

326

351

371

-

367

395

417

-

406

436

461

-

 

 

 

LO PR

107

 

114

124

-

113

120

 

131

-

118

125

137

-

124

131

144

-

130

138

150

-

134

143

156

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

45.3

 

46.7

50.5

54.2

44.3

45.6

 

49.4

53.0

43.2

44.5

48.2

51.7

42.2

43.4

47.0

50.4

40.1

41.3

44.7

47.9

37.1

38.2

41.4

44.4

 

 

 

S/T

0.87

 

0.78

0.59

0.38

0.90

0.81

 

0.61

0.39

0.93

0.83

0.63

0.40

0.96

0.85

0.65

0.42

0.99

0.89

0.67

0.43

1.00

0.89

0.68

0.44

 

 

1800

Delta T

20

 

19

15

11

20

19

 

15

11

20

19

15

11

21

19

16

11

20

19

15

11

19

17

14

10

 

 

KW

3.23

 

3.29

3.38

3.48

3.45

3.52

 

3.62

3.73

3.65

3.73

3.84

3.95

3.83

3.91

4.02

4.15

3.98

4.06

4.18

4.31

4.10

4.19

4.32

4.46

 

 

 

AMPS

14.0

 

14.3

14.7

15.1

14.9

15.2

 

15.6

16.1

16.0

16.3

16.7

17.3

16.9

17.2

17.7

18.3

17.8

18.2

18.7

19.3

18.7

19.1

19.6

20.3

 

 

 

HI PR

236

 

254

268

280

265

285

 

301

314

301

324

342

357

343

369

390

407

386

415

439

458

427

459

485

506

 

 

 

LO PR

113

 

120

131

139

119

127

 

138

147

124

132

144

153

130

138

151

161

136

145

158

169

141

150

164

174

 

 

 

MBh

44.0

 

45.3

49.1

52.7

43.0

44.3

 

47.9

51.4

42.0

43.2

46.8

50.2

41.0

42.2

 

45.6

49.0

38.9

40.1

43.4

46.5

36.0

37.1

40.2

43.1

 

 

 

S/T

0.83

 

0.74

0.56

0.36

0.86

0.77

 

0.58

0.37

0.88

0.79

0.60

0.38

0.91

0.82

 

0.62

0.40

0.95

0.85

0.64

0.41

0.95

0.85

0.65

0.42

 

75

1600

Delta T

21

 

19

16

11

21

20

 

16

11

21

20

16

11

21

20

 

16

11

21

19

16

11

20

18

15

10

 

KW

3.21

 

3.27

3.36

3.46

3.43

3.50

 

3.60

3.71

3.62

3.70

3.81

3.92

3.80

3.88

 

3.99

4.12

3.95

4.03

4.15

4.28

4.07

4.16

4.29

4.42

 

 

 

AMPS

13.9

 

14.2

14.5

15.0

14.8

15.1

 

15.5

16.0

15.9

16.2

16.6

17.1

16.8

17.1

 

17.6

18.1

17.7

18.0

18.5

19.1

18.5

18.9

19.5

20.1

 

 

 

HI PR

234

 

252

266

277

262

282

 

298

311

298

321

339

354

340

366

 

386

403

382

411

434

453

422

454

480

501

 

 

 

LO PR

112

 

119

130

138

118

125

 

137

146

123

130

142

152

129

137

 

149

159

135

144

157

167

140

148

162

173

 

 

 

MBh

40.6

 

41.8

45.3

48.6

39.7

40.9

 

44.2

47.5

38.7

39.9

43.2

46.3

37.8

38.9

 

42.1

45.2

35.9

37.0

40.0

42.9

33.3

34.2

37.1

39.8

 

 

 

S/T

0.80

 

0.72

0.54

0.35

0.83

0.74

 

0.56

0.36

0.85

0.76

0.58

0.37

0.88

0.79

0.59

0.38

0.91

0.82

0.62

0.40

0.92

0.82

0.62

0.40

 

 

1400

Delta T

21

 

20

16

11

22

20

 

16

11

22

20

16

11

22

20

16

11

22

20

16

11

20

19

15

10

 

 

KW

3.14

 

3.20

3.29

3.38

3.35

3.42

 

3.52

3.62

3.54

3.61

3.72

3.83

3.71

3.79

3.90

4.02

3.85

3.93

4.05

4.18

3.98

4.06

4.18

4.32

 

 

 

AMPS

13.6

 

13.9

14.2

14.7

14.5

14.8

 

15.2

15.6

15.5

15.8

16.2

16.7

16.4

16.7

17.2

17.7

17.2

17.6

18.1

18.7

18.1

18.5

19.0

19.6

 

 

 

HI PR

227

 

244

258

269

254

274

 

289

302

289

311

329

343

330

355

375

391

371

399

421

439

410

441

466

486

 

 

 

LO PR

108

 

115

126

134

114

122

 

133

141

119

126

138

147

125

133

145

154

131

139

152

162

135

144

157

167

41

 

* IDB: Entering Indoor Dry Bulb Temperature

 

 

 

NOTE: Shaded area is ACCA (TVA) conditions

 

 

 

 

 

 

 

 

 

 

 

 

High and low pressures are measured at the liquid and suction access fittings.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING PERFORMANCE DATA 5MM COILS GPC1349H41AA

Image 41
Contents Technical Manual For any injury or property damage Product IdentificationGoodman will not be responsible Mm model Specific information begins on Location and Clearances Product DesignProduct Design GPC1324-60H41 Product DimensionsPart Number Description AccessoriesCircuit #1 Circuit #2 Model Minimum Circuit Maximum Actual Electrical Data *Blower Only, Heat ModeKW & BTU Heat Kit Usage Ampacity Protection ampsMed Blower Performance DataFormulas Performance DataGPC1324H41 GPC1330H41 Package Cooling Specifications GPC1324-30H41AA24.2 13.013.4 Orifice Refrigerant Charge R-410A OzOrrifice Orifice Refrigerant Charge R-410A Oz Package Cooling Specifications GPC1348-60H41BAGPC1348H41B GPC1360H41B 105 115 Cooling Performance DataGPC1324H41AA 152 Airflow GPC1330H41AA151 GPC1336H41AA 146 GPC1342H41AA 149 GPC1348H41BA 17.4 17.0 37.818.3 18.8 19.4 19.2 19.8 20.4 238 257GPC1360H41BA 148 Performance Test GPC1324-42H41AA GPC1348H41BA Wiring DiagramsGPC1360H41BA GPC 13 Seer R-410A Mm Package Air Conditioners Enum Models with 5MM Coils Package Cooling Specifications GPC1324-36H41AB5MM Package Cooling SpecificationsCooling Performance Data 5MM Coils GPC1324H41AB 10.0 10.2 10.5 24.0222 391 412 430Cooling Performance Data 5MM Coils GPC1330H41AB 11.1 11.4 11.8 10.6 10.9 11.2412 391 421 444 463 465 491 512Cooling Performance Data 5MM Coils GPC1336H41AB 29.0 31.0 33.1 31.3 33.4 35.728.9 30.9 33.0 26.8 28.6 30.6Cooling Performance Data 5MM Coils GPC1342H41AB 1580 39.614.4 14.3 14.5 230Cooling Performance Data 5MM Coils GPC1349H41AA 40.5 43.2 46.2 23837.5 40.0 42.8 37.3 39.9 42.6Cooling Performance Data 5MM Coils GPC1360H41BB 20.8 194823.8 23.6 24.4 25.2Cooling Performance Data GPC1324-42H41AB GPC1349H41AA GPC1360H41BB

GPC1324H41A, GPC 13 SEER R-410A specifications

The Goodman GPC 13 SEER R-410A, model GPC1324H41A, represents a reliable and efficient option for those seeking a powerful packaged air conditioning system. This unit is designed to provide cooling for both residential and light commercial applications, offering a blend of performance, durability, and affordability.

One of the standout features of the Goodman GPC 13 is its cooling efficiency rating of 13 SEER (Seasonal Energy Efficiency Ratio). This efficiency rating not only underscores its capability to provide effective cooling but also ensures that consumers can enjoy lower utility bills compared to older, less efficient systems. The use of R-410A refrigerant is another significant characteristic of this model, as R-410A is known for its enhanced performance and environmentally friendly properties, being free from hydrochlorofluorocarbons (HCFCs) that can deplete the ozone layer.

The GPC1324H41A is equipped with a high-quality scroll compressor which contributes to its quiet operation and improved reliability. Scroll compressors have fewer moving parts than traditional compressors, which translates to reduced wear and tear, ensuring a longer lifespan for the unit. Additionally, this model includes an efficient evaporator coil that maximizes heat exchange, further enhancing the overall cooling performance.

Another notable characteristic of the Goodman GPC 13 is its design for easy installation and maintenance. The unit features a compact, all-in-one design that simplifies the installation process, making it suitable for various settings without requiring extensive modifications. Moreover, the GPC1324H41A features easily accessible components, which facilitates routine maintenance and servicing, ultimately leading to improved system longevity.

The robust construction of the weather-resistant cabinet ensures that the unit can withstand various environmental conditions, making it an ideal choice for outdoor installations. The durable finish not only adds to the unit’s aesthetics but also helps protect it from rust and corrosion, ensuring a reliable performance over the years.

In summary, the Goodman GPC 13 SEER R-410A, model GPC1324H41A, combines efficiency, durability, and ease of use. With its reliable features, advanced technologies, and environmentally conscious design, this packaged air conditioning system stands out as a solid investment for homeowners and businesses looking to enhance their indoor comfort.