Goodmans GPC 13 SEER R-410A, GPC1324H41A Electrical Data *Blower Only, Heat Mode, Kw & Btu

Page 8

PRODUCT DESIGN

 

 

 

 

GPC13[24-60]H41**

ELECTRICAL DATA (*Blower Only, Heat Mode)

 

 

 

 

 

 

 

 

 

 

 

 

 

Circuit #1

 

Circuit #2

 

Model and

Minimum Circuit

Maximum

Minimum Circuit

Maximum

Actual

Overcurrent

Overcurrent

kW & BTU

Heat Kit Usage

Ampacity

 

Ampacity

 

 

Protection (amps)

 

Protection (amps)

at 240V

 

at 208 / 240V

 

at 208 / 240V

 

 

 

at 208 / 240V

 

at 208 / 240V

 

 

 

 

 

 

 

 

GPC1324H41*

 

 

 

--

--

 

--

--

HKR05*,C*

24

/ 27

 

30 / 30

--

 

--

4.75 / 16,200

HKR08*,C*

33

/ 38

 

40 / 40

--

 

--

7.0 / 23,800

HKR10*,C*

45

/ 51

 

60 / 60

--

 

--

9.5 / 32,400

GPC1330H41*

2.4

/ 2.4

 

--

--

 

--

--

HKR05*,C*

24

/ 27

 

30 / 30

--

 

--

4.75 / 16,200

HKR08*,C*

34

/ 39

 

40 / 40

--

 

--

7.0 / 23,800

HKR10*,C*

45

/ 52

 

60 / 60

--

 

--

9.5 / 32,400

HKR15*,C*

45

/ 52

 

60 / 60

22 / 25

 

30 / 30

14.25 / 48,600

GPC1336H41*

 

 

 

--

--

 

--

--

HKR05*,C*

24

/ 27

 

30 / 30

--

 

--

4.75 / 16,200

HKR08*,C*

34

/ 39

 

40 / 40

--

 

--

7.0 / 23,800

HKR10*,C*

45

/ 52

 

60 / 60

--

 

--

9.5 / 32,400

HKR15*,C*

45

/ 52

 

60 / 60

22 / 25

 

30 / 30

14.25 / 48,600

GPC1342H41*

 

 

 

--

--

 

--

--

HKR05*,C*

25

/ 27

 

30 / 30

--

 

--

4.75 / 16,200

HKR08*,C*

34

/ 39

 

40 / 40

--

 

--

7.0 / 23,800

HKR10*,C*

46

/ 52

 

60 / 60

--

 

--

9.5 / 32,400

HKR15*,C*

46

/ 52

 

60 / 60

22 / 25

 

30 / 30

14.25 / 48,600

HKR20*,C*

46

/ 52

 

60 / 60

43 / 49

 

60 / 60

19.5 / 66,500

GPC1348H41*

 

 

 

--

--

 

--

--

HKR05*,C*

25

/ 28

 

30 / 30

--

 

--

4.75 / 16,200

HKR08*,C*

34

/ 40

 

40 / 40

--

 

--

7.0 / 23,800

HKR10*,C*

46

/ 53

 

60 / 60

--

 

--

9.5 / 32,400

HKR15*,C*

46

/ 52

 

60 / 60

22 / 25

 

30 / 30

14.25 / 48,600

HKR20*,C*

46

/ 52

 

60 / 60

43 / 49

 

60 / 60

19.5 / 66,500

GPC1349H41*

 

 

 

--

--

 

--

--

HKR05*,C*

25

/ 28

 

30 / 30

--

 

--

4.75 / 16,200

HKR08*,C*

34

/ 40

 

40 / 40

--

 

--

7.0 / 23,800

HKR10*,C*

46

/ 53

 

60 / 60

--

 

--

9.5 / 32,400

HKR15*,C*

46

/ 52

 

60 / 60

22 / 25

 

30 / 30

14.25 / 48,600

HKR20*,C*

46

/ 52

 

60 / 60

43 / 49

 

60 / 60

19.5 / 66,500

GPC1360H41*

 

 

 

--

--

 

--

--

HKR05*,C*

26

/ 30

 

30 / 30

--

 

--

4.75 / 16,200

HKR08*,C*

36

/ 40

 

40 / 40

--

 

--

7.0 / 23,800

HKR10*,C*

48

/ 54

 

60 / 60

--

 

--

9.5 / 32,400

HKR15*,C*

48

/ 54

 

60 / 60

22 / 25

 

30 / 30

14.25 / 48,600

HKR20*,C*

48

/ 54

 

60 / 60

43 / 49

 

60 / 60

19.5 / 66,500

IMPORTANT NOTE: A separate power supply is required for the HKR heater kit.

All wires and overcurrent protection devices are sized for use with electric heaters only and without WARNING refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent

protection during refrigeration cycle.

8

Image 8
Contents Technical Manual For any injury or property damage Product IdentificationGoodman will not be responsible Mm model Specific information begins on Product Design Location and ClearancesProduct Design Product Dimensions GPC1324-60H41Accessories Part Number DescriptionElectrical Data *Blower Only, Heat Mode Circuit #1 Circuit #2 Model Minimum Circuit Maximum ActualKW & BTU Heat Kit Usage Ampacity Protection ampsBlower Performance Data MedPerformance Data FormulasPackage Cooling Specifications GPC1324-30H41AA GPC1324H41 GPC1330H4113.0 24.213.4 Orifice Refrigerant Charge R-410A OzOrrifice Orifice Refrigerant Charge R-410A Oz Package Cooling Specifications GPC1348-60H41BAGPC1348H41B GPC1360H41B 105 115 Cooling Performance DataGPC1324H41AA 152 GPC1330H41AA Airflow151 GPC1336H41AA 146 GPC1342H41AA 149 GPC1348H41BA 37.8 17.4 17.018.3 18.8 19.4 19.2 19.8 20.4 238 257GPC1360H41BA 148 Performance Test Wiring Diagrams GPC1324-42H41AA GPC1348H41BAGPC1360H41BA GPC 13 Seer R-410A Mm Package Air Conditioners Enum Package Cooling Specifications GPC1324-36H41AB Models with 5MM CoilsPackage Cooling Specifications 5MMCooling Performance Data 5MM Coils GPC1324H41AB 24.0 10.0 10.2 10.5222 391 412 430Cooling Performance Data 5MM Coils GPC1330H41AB 10.6 10.9 11.2 11.1 11.4 11.8412 391 421 444 463 465 491 512Cooling Performance Data 5MM Coils GPC1336H41AB 31.3 33.4 35.7 29.0 31.0 33.128.9 30.9 33.0 26.8 28.6 30.6Cooling Performance Data 5MM Coils GPC1342H41AB 39.6 158014.4 14.3 14.5 230Cooling Performance Data 5MM Coils GPC1349H41AA 238 40.5 43.2 46.237.5 40.0 42.8 37.3 39.9 42.6Cooling Performance Data 5MM Coils GPC1360H41BB 1948 20.823.8 23.6 24.4 25.2Cooling Performance Data GPC1324-42H41AB GPC1349H41AA GPC1360H41BB

GPC1324H41A, GPC 13 SEER R-410A specifications

The Goodman GPC 13 SEER R-410A, model GPC1324H41A, represents a reliable and efficient option for those seeking a powerful packaged air conditioning system. This unit is designed to provide cooling for both residential and light commercial applications, offering a blend of performance, durability, and affordability.

One of the standout features of the Goodman GPC 13 is its cooling efficiency rating of 13 SEER (Seasonal Energy Efficiency Ratio). This efficiency rating not only underscores its capability to provide effective cooling but also ensures that consumers can enjoy lower utility bills compared to older, less efficient systems. The use of R-410A refrigerant is another significant characteristic of this model, as R-410A is known for its enhanced performance and environmentally friendly properties, being free from hydrochlorofluorocarbons (HCFCs) that can deplete the ozone layer.

The GPC1324H41A is equipped with a high-quality scroll compressor which contributes to its quiet operation and improved reliability. Scroll compressors have fewer moving parts than traditional compressors, which translates to reduced wear and tear, ensuring a longer lifespan for the unit. Additionally, this model includes an efficient evaporator coil that maximizes heat exchange, further enhancing the overall cooling performance.

Another notable characteristic of the Goodman GPC 13 is its design for easy installation and maintenance. The unit features a compact, all-in-one design that simplifies the installation process, making it suitable for various settings without requiring extensive modifications. Moreover, the GPC1324H41A features easily accessible components, which facilitates routine maintenance and servicing, ultimately leading to improved system longevity.

The robust construction of the weather-resistant cabinet ensures that the unit can withstand various environmental conditions, making it an ideal choice for outdoor installations. The durable finish not only adds to the unit’s aesthetics but also helps protect it from rust and corrosion, ensuring a reliable performance over the years.

In summary, the Goodman GPC 13 SEER R-410A, model GPC1324H41A, combines efficiency, durability, and ease of use. With its reliable features, advanced technologies, and environmentally conscious design, this packaged air conditioning system stands out as a solid investment for homeowners and businesses looking to enhance their indoor comfort.