Graco 256713, 256714, 223540, 224348 important safety instructions Fire and Explosion Hazard

Page 4

WARNING

FIRE AND EXPLOSION HAZARD

Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.

DGround the equipment and the object being sprayed. Refer to Grounding on page 5.

DIf there is any static sparking or you feel an electric shock while using this equipment, stop spray- ing/dispensing immediately. Do not use the equipment until you identify and correct the problem.

DProvide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being sprayed/dispensed.

DKeep the spray/dispense area free of debris, including solvent, rags, and gasoline.

DElectrically disconnect all equipment in the spray/dispense area.

DExtinguish all open flames or pilot lights in the spray/dispense area.

DDo not smoke in the spray/dispense area.

DDo not turn on or off any light switch in the spray/dispense area while operating or if fumes are present.

DDo not operate a gasoline engine in the spray/dispense area.

TOXIC FLUID HAZARD

Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.

DKnow the specific hazards of the fluid you are using.

DStore hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines.

DAlways wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and solvent manufacturer.

4308118

Image 4
Contents Instructions-Parts List Model 224348, Series C Ratio President r Pump Model 224350, Series CTable of Contents SymbolsSkin Injection Hazard Fire and Explosion Hazard Installation GroundingTypical Installation KEYSystem Accessories Mounting AccessoriesAir Line Accessories Fluid Line Accessories308118 Flush the Pump Before Using Pressure Relief ProcedureOperation Starting and Adjusting the Pump Shutdown and Care of the PumpAIR Motor Plate Page Troubleshooting Problem Cause SolutionDisconnecting the Displacement Pump ServiceReconnecting the Displacement Pump Displacement Pump Service DisassemblyReassembly See Detail a Detail a Throat Packings Parts 106 107105† 102 109† 112 101 Base Description Qty Ring PtfeTechnical Data 101 President Category DataFluid Outlet Pressure Chart Air Consumption ChartTechnical Data 51 Monark Outlet Pump Layout Dimensions Mounting HoleModel 224348 Shown 308118 Graco Standard Warranty Graco Information