NorthStar Navigation D210 Appendix B Troubleshooting, No display, Erratic readings while moored

Page 11

Appendix B - Troubleshooting

No display:

1.Check DC power connections and DC polarity with voltmeter.

2.Check fuse.

No depth reading (--) at all depths:

1.Check transducer for growth or multiple coats of paint.

2.Check the transducer cable for cuts and sharp bends.

3.Check that the transducer connection behind the Explorer D210 is firm and free of corrosion.

Erratic readings while moored:

1.Check transducer for growth or multiple coats of paint.

Erratic readings while moving:

1.Cavitation (air) under the face of the transducer. Review installation and reinstall if necessary.

Erratic readings only while engine is running:

1.Re-route power and transducer cables away from engine, ignition wires and battery cables.

2.Add feed-through filter capacitor on the positive terminal of the ignition coil.

3.Add an alternator whine filter to alternator.

4.Replace spark plug wire with resistive type.

Northstar Explorer D210 Installation and Operation Manual

11

Image 11
Contents Explorer D210 Important Safety Information Contents Deep Alarm AlarmsAlarms On/Off Shallow AlarmPress simultaneously Instrument SetupHold down during power up Keel/Surface OffsetUnits of Measure Transducer SettingOFF Hold down during power up Dual Station OperationLinked or Separate Selection Master/Slave SelectionTighten the mounting nut until the bracket is secure MaintenanceInstallation Instrument InstallationRed + Terminal Black Terminal Orange External Buzzer WiringBracket RCA Jack Connector Buzzer 600 mm 24 inch Power Cord Red + Black Brown OrangeAppendix a Specifications Erratic readings while moored Appendix B TroubleshootingNo display No depth reading -- at all depthsAmericas Europe