UNIDEN Model uh089sx UHF CB Radio
Introduction
The Uniden uh089sx is designed to provide you with years of trouble free service. Its rugged components and materials are capable of withstanding harsh environments. Please read this Operating Manual carefully to ensure you gain the optimum performance of the unit
The citizen band radio service is licenced in Australia by ACMA
Features
Transmit & Receive FM 40CH
LCD Display with Backlight Signal Strength Meter
RF Power Meter
Speaker Audio Volume Level Meter Instant Channel
One touch Instant Channel recalling Duplex Capability (from CH01 - CH08 per channel)
Group Scan and Priority Channel Watch Open Scan
Scan Channel Memory On/Off separately
with Open Scan, Group Scan
Rotary Channel Select |
|
Busy Channel |
|
Roger Beep Function On/Off |
|
2 Different CallTones | Coded |
38 | |
Squelch System) and 104 additional | DCS |
(Digital Coded Squelch) codes that are user selectable
Variable Squelch Level adjust
Volume Control with Power On/Off Switch VOX (Voice Activated Function)
10 Steps VOX Mic sensitivity adjustment
Preventive Maintenance:
The following system checks should be made every six to twelve months:
Check the Standing Wave Ratio (SWR).
Inspect the tightness of all electrical connections.
Inspect the antenna coaxial cable for wear or breaks on the shielding.
Inspect the tightness of all screws and other mounting hardware.
Troubleshooting:
Should the unit malfunction or perform poorly, follow these procedures:
If the transceiver is completely inoperative: Check the power cord and fuse.
If there is trouble with receiving: Check the VOLUME control setting. Be sure the SQUELCH is adjusted properly. Possibly the radio is
If there is trouble with transmitting: Check that the transmission line (coaxial cable) is securely connected to the ANTENNA connector. Check that the antenna is fully extended for proper operation. Check that all transmission line (coaxial cable) connections are secure and free of corrosion.
Blackening may occur on the Liquid Crystal Display if the uh089sx has been subjected to extreme high temperature (above 60°C) . This is not a fault. Normal LCD operation resumes when the temperature stabilizes back to standard operating operating condition