La Crosse Technology WS-1613-IT Positioning, Switching ON/OFF the Buzzer, LOW Battery Indicator

Page 8

2.Press and hold the SET key for about 2 seconds, then the "RESET" icon will appear at the bottom part of the LCD.

3.Press the + key once, then the stored value will be reset to the current value

 

and current time.

4.

Press the ALARM key to return to normal display mode.

10.Total rainfall amount

The total rainfall measurement is displayed in the fourth section of the LCD, in the unit of mm or inch. It shows the total rainfall accumulated since last reset of the Weather Center.

In normal display mode, press the MIN/MAX key 10 times to show the total rainfall value. The "RESET" icon will also be shown at the same time.

The total rainfall value is counted from this time and date

Total rainfall

value

42

1.The distance of the Weather Center or transmitter should be at least 5 to 6.5 feet away from any interfering sources such as computer monitors or TV sets.

2.Avoid positioning the Weather Center onto or in the immediate proximity of metal doors or window frames.

3.Using other electrical products such as headphones, speakers, or cordless phones operating on the same signal frequency (915 MHz) may prevent correct signal transmission and reception.

4.Neighbors using electrical devices operating on the 915 MHz signal frequency can also cause interference.

5.“Visibility” of Weather Center and Thermo-hygro sensor (e.g. through a window) increases the range.

Note:

When the 915 MHz signal is received, do not re-open the battery compartment cover of either the transmitter or Weather Center, as the batteries may spring free from the contacts and force a false reset. Should this happen accidentally then reset all units (see Setting up above) otherwise transmission problems may occur.

During normal operation, after the outdoor display shows "- - -", the weather station will change to receive the outdoor data every 15 minutes, until the data is read. Then the reception period will return to 4.5 seconds.

If no reception is possible despite the observation of these factors, all system units have to be reset (see Setting up).

POSITIONING

Prior to permanently affixing any of the units, please ensure the following points are considered:

45

To reset the rainfall reading, press the + key once when the Rainfall value and "Reset" icon is shown. Then the total rainfall amount will be reset to 0, and the time updated to current time.

Note:

After power up, the time and date and total rainfall is displayed as "- - -". After time is adjusted manually, the set time will be shown.

SWITCHING ON/OFF THE BUZZER

User may choose to turn off the buzzer so that when the time alarm is switched on and activated, the buzzer will not sound but we can still see the alarm icon (((y)))

flashing on the LCD for time alarm.

On the other hand, when the buzzer is turned off and any weather alarm is activated, the particular weather digits will flash to show user that the weather condition is being out of the preset threshold value, yet the buzzer will not sound.

To switch off the buzzer:

1.In normal display mode, press and hold the SET key until the icon "BUZZER OFF" is shown at the right side above the Wind direction scale. The LCD will change to setting mode.

2.Press ALARM key once to return to the normal display mode. The "BUZZER OFF" icon will still be shown.

BUZZER OFF icon

43

Cable lengths of the units meet with your distance requirements at the point of fixing

Signals from the sensors can be received by the base station at points of mounting

Weather Center

The Weather Center has been designed to be hung onto wall or free standing with the foldout stand.

To wall mount

Choose a sheltered place, such as under the eve of a roof. Avoid direct rain and sunshine.

Before wall mounting, please check that the outdoor temperature and humidity values can be received from the desired locations. To wall mount:

1. Fix a screw (not supplied) into the desired wall, leaving the head extended out the by about 5mm.

2. Hang the Center onto the screw. Remember to ensure that it locks into place before releasing.

Thermo-hygro Sensor

Rain Cover

 

 

 

 

 

 

 

 

Main Unit

 

 

 

 

 

 

 

 

 

 

 

46

Wall Bracket

To re-enable the buzzer:

1.When the BUZZER OFF icon is shown on LCD, press the SET key shortly and the BUZZER OFF icon will disappear.

2.Press ALARM key once to return to the normal display mode. The "BUZZER OFF" icon will no longer be shown. Then the alarm will sound normally.

LOW BATTERY INDICATOR

The low battery indicator of the Weather Center and the Thermo-hygro sensor will be displayed at the top and bottom portion of the LCD respectively when the battery power is low. It is recommended to replace the batteries in all units on an annual basis to ensure optimum accuracy of the system.

Note:

After battery change, both the Weather Center and the Thermo-hygro sensor need to be reset (see note ”Setting up”)

The History data record will be clear after the battery change.

OUTDOOR TRANSMITTER 915 MHz RECEPTION

The outdoor temperature, humidity, wind data and rainfall are transmitted from the Thermo-hygro sensor every 4.5 seconds. The Weather Center will then be synchronized to the Thermo-hygro sensor to receiver outdoor data. The transmission range (up to 330 feet) of the Outdoor Thermo-hygro sensor may be affected by the ambient temperature. At cold temperatures the transmitting distance may be decreased. Please keep this in mind when placing the transmitter.

If the outdoor data are not being received within 30 seconds after setting up (or the outdoor display shows “- - -“ in the outdoor section of the Weather Center after consecutive failed attempts during normal operation). Please check the following points:

44

An ideal mounting place for the Thermo-hygro sensor would be the outer wall beneath the extension of a roof, as this will protect the sensor from direct sunlight and other extreme weather conditions.

To wall mount, use the 2 screws to affix the wall bracket to the desired wall, plug in the Thermo-hygro sensor to the bracket and secure both parts by the use of the supplied screw and ensure that the cables from the wind and rain sensors are correctly plugged in otherwise data transmission errors could occur.

Wind Sensor

Wind vane

Vertical mast

Wind fan

Horizontal panel

Firstly, check that the wind-fan and the wind-vane can rotate freely before fixing the unit. For correct and accurate readings it is important to mount the sensor so that the front (marked E) is pointing in East-West direction. The wind sensor should now be

47

Image 8
Contents Features Professional Weather CenterSetting UP Batteries into the Bonus Receiver belowBattery Change Manual SettingFunction Keys LCD ScreenTime Alarm Setting Weather Alarm Operations High and LOW Outdoor Humidity Alarm SettingHigh and LOW Outdoor Temperature Alarm Setting Wind Speed Alarm SettingWeather Forecast and Weather Tendency Wind Direction and Wind Speed MeasurementRainfall Measurement Viewing the History DataMin outdoor temperature with the date and time of recording Reset the MIN/MAX Weather DataViewing the MIN/MAX Weather Data To view the weather historyPositioning Switching ON/OFF the BuzzerLOW Battery Indicator Bonus Receiver Functions and Settings LCD Screen and SettingsManual Settings Positioning the Bonus ReciverCare and Maintenance SpecificationsWarranty Liability Disclaimer