Goodman Mfg SSZ 14 SEER service manual Split System Heating Performance, Expanded Performance Data

Page 22

SPLIT SYSTEM HEATING PERFORMANCE

EXPANDED PERFORMANCE DATA

MODEL: SSZ140181A* / CA*F3131*6A* +TXV / MBR800**-1

 

 

 

 

 

 

 

 

HEATING OPERATION

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

 

30

25

20

17

 

15

10

5

0

 

-5

-10

 

MBh

22.6

21.4

20.2

18.8

18.0

17.4

16.2

14.9

 

12.8

11.8

10.9

10.3

 

9.9

8.9

7.9

6.9

 

5.9

4.8

 

Delta T

34.9

33.1

31.1

29.1

27.8

26.9

25.0

23.1

 

19.7

18.2

16.8

15.8

 

15.3

13.7

12.1

10.6

 

9.0

7.4

 

KW

1.56

1.53

1.50

1.47

1.45

1.44

1.41

1.38

 

1.39

1.36

1.32

1.31

 

1.29

1.26

1.23

1.20

 

1.17

1.14

 

AMPS

7.0

6.5

6.1

5.7

5.5

5.4

5.1

4.9

 

4.7

4.5

4.2

4.1

 

4.1

3.9

3.6

3.4

 

3.2

2.9

 

COP

4.23

4.09

3.93

3.75

3.62

3.54

3.36

3.16

 

2.70

2.55

2.40

2.30

 

2.24

2.06

1.87

1.67

 

1.47

1.23

 

EER

14.5

14.0

13.4

12.8

12.4

12.1

11.5

10.8

 

9.2

8.7

8.2

7.9

 

7.6

7.0

6.4

5.7

 

5.0

4.2

 

HI PR

385

369

355

339

331

325

312

300

 

287

274

263

257

 

252

243

234

224

 

216

208

 

LO PR

149

138

129

118

112

108

99

88

 

80

71

62

58

 

56

47

41

34

 

30

24

 

 

 

 

 

 

 

EXPANDED PERFORMANCE DATA

 

 

 

 

 

 

 

MODEL: SSZ140241A* / CA*F3636*6A*+TXV / MBR800**-1

 

 

 

 

 

 

 

 

 

HEATING OPERATION

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

 

30

25

20

17

 

15

10

5

0

 

-5

-10

 

MBh

30.2

28.6

26.9

25.1

24.0

23.3

21.6

19.9

 

17.9

16.6

15.2

14.4

 

13.9

12.4

11.0

9.6

 

8.2

6.7

 

Delta T

32.9

31.1

29.3

27.4

26.1

25.3

23.5

21.7

 

19.5

18.0

16.6

15.7

 

15.1

13.5

12.0

10.5

 

8.9

7.3

 

KW

2.08

2.04

2.00

1.96

1.94

1.92

1.89

1.85

 

1.87

1.82

1.78

1.76

 

1.74

1.70

1.66

1.62

 

1.58

1.54

 

AMPS

8.1

7.9

7.7

7.5

7.4

7.3

7.2

7.1

 

7.0

6.9

6.8

6.7

 

6.7

6.6

6.5

6.3

 

6.2

6.1

 

COP

4.24

4.09

3.93

3.74

3.62

3.54

3.35

3.16

 

2.81

2.65

2.50

2.39

 

2.33

2.14

1.94

1.73

 

1.52

1.28

 

EER

14.5

14.0

13.4

12.8

12.4

12.1

11.4

10.8

 

9.6

9.1

8.5

8.2

 

7.9

7.3

6.6

5.9

 

5.2

4.4

 

HI PR

373

358

344

329

321

315

303

290

 

278

266

255

249

 

245

235

226

217

 

209

202

 

LO PR

143

133

124

114

108

104

95

85

 

77

68

60

56

 

54

46

39

33

 

29

23

 

 

 

 

 

 

 

EXPANDED PERFORMANCE DATA

 

 

 

 

 

 

 

MODEL: SSZ140301A* / CA*F3642*6A*+TXV / MBR1600**-1

 

 

 

 

 

 

 

 

HEATING OPERATION

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

 

30

25

20

17

 

15

10

5

0

 

-5

-10

 

MBh

36.5

34.5

32.5

30.4

29.0

28.1

26.1

24.1

 

22.6

20.9

19.2

18.2

 

17.5

15.7

13.9

12.1

 

10.3

8.5

 

Delta T

32.1

30.4

28.6

26.8

25.6

24.8

23.0

21.2

 

19.9

18.4

17.0

16.0

 

15.4

13.8

12.3

10.7

 

9.1

7.5

 

KW

2.40

2.36

2.32

2.27

2.25

2.23

2.19

2.14

 

2.20

2.15

2.11

2.08

 

2.06

2.01

1.97

1.92

 

1.87

1.83

 

AMPS

11.8

10.6

9.6

8.7

8.2

8.0

7.2

6.6

 

6.1

5.6

5.1

4.9

 

4.8

4.3

3.6

3.1

 

2.5

1.8

 

COP

4.44

4.28

4.10

3.91

3.78

3.69

3.50

3.29

 

3.01

2.84

2.67

2.55

 

2.48

2.28

2.07

1.85

 

1.62

1.36

 

EER

15.2

14.6

14.0

13.4

12.9

12.6

11.9

11.2

 

10.3

9.7

9.1

8.7

 

8.5

7.8

7.1

6.3

 

5.5

4.6

 

HI PR

360

346

332

318

310

304

292

281

 

269

257

247

241

 

236

227

219

210

 

202

195

 

LO PR

137

127

119

110

104

100

92

82

 

74

66

58

54

 

52

44

38

32

 

28

22

 

 

 

 

 

 

 

EXPANDED PERFORMANCE DATA

 

 

 

 

 

 

 

MODEL: SSZ140361A* / CA*F4860C6A*+TXV / MBR1600**-1

 

 

 

 

 

 

 

 

HEATING OPERATION

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

 

MBh

43.5

41.2

38.8

36.2

34.6

33.5

31.1

28.7

28.8

26.6

24.5

23.1

22.3

20.0

17.7

15.5

13.2

10.8

 

Delta T

38.4

36.3

34.2

31.9

30.5

29.6

27.5

25.3

25.4

23.5

21.6

20.4

19.6

17.6

15.6

13.6

11.6

9.5

 

KW

3.05

2.99

2.94

2.88

2.84

2.82

2.76

2.71

2.78

2.72

2.66

2.62

2.60

2.53

2.47

2.41

2.35

2.29

 

AMPS

13.8

12.8

12.0

11.3

10.9

10.7

10.1

9.6

9.2

8.9

8.4

8.3

8.2

7.8

7.3

6.9

6.4

5.8

 

COP

4.17

4.02

3.86

3.68

3.56

3.48

3.30

3.11

3.03

2.86

2.70

2.58

2.51

2.31

2.10

1.87

1.64

1.38

 

EER

14.3

13.8

13.2

12.6

12.2

11.9

11.3

10.6

10.4

9.8

9.2

8.8

8.6

7.9

7.2

6.4

5.6

4.7

 

HI PR

384

368

353

338

330

324

311

299

286

273

262

256

251

242

233

223

215

208

 

LO PR

144

134

125

115

109

105

96

86

77

69

61

56

54

46

40

33

29

23

 

High pressure is measured at the suction service valve ( the larger valve).

AMPS = Outdoor unit amps (comp.+fan)

Low pressure is measured at the gauge port connection.

KW = Total system power

Calculations are based on nominal CFM and 70 °F indoor dry bulb.

 

*Note: Shaded area is ARI Rating Conditions at 47° outdoor ambient temberature

 

22

 

Image 22
Contents Technical Manual 036 Product IdentificationDo not connect or use any device Product Design AA AAHeat Pump Specifications SSZ14018,30, 342,48,601AA-AE SSZ140241AA-AH SSZ140361AA-AGSSZ14018,30,42,48,601AF SSZ140241AJ SSZ140361AH Cooling Performance Data SSZ140181A355 Model SSZ140181A* / CA*F3131*6A* +TXV / MBR800**-118.0 144SSZ140241A Model SSZ140241A* / CA*F3636*6A*+TXV / MBR800**-1370 24.012.0 149SSZ140301A 368 28.8151 SSZ140361A Model SSZ140361A* / CA*F4860*6A*+TXV / MBR1600**-1364 34.611.4 142SSZ140421A Model SSZ140421A* / CA*F4860*6A*+TXV / MBR2000**-1363 40.012.9 145343 SSZ140481A43.9 42.6362 Model SSZ140481A* / CA*F4860*6A*+TXV / MBR2000**-146.0 143SSZ140601A Model SSZ140601A* / CA*F4860*6A*+TXV / MBE2000**-112.3 56.5365 Performance Data 18,000 13,203 797 483Split System Heating Performance Expanded Performance DataOutdoor Ambient Temperature 41.0Capacity Btuh Heating Specifications19.2 51.54 Performance Test Wiring To change, always0241AJ, 0361AH 601AF

SSZ 14 SEER specifications

Goodman Manufacturing has established a reputation for producing reliable and efficient HVAC systems, and the SSZ 14 SEER model follows this tradition. This ducted heat pump is engineered to offer effective heating and cooling, making it a versatile choice for homeowners looking to maintain comfortable indoor temperatures year-round.

One of the standout features of the Goodman SSZ 14 is its impressive 14 SEER (Seasonal Energy Efficiency Ratio) rating. This efficiency metric indicates that the heat pump can cool a designated space while consuming less energy compared to many standard systems, which translates to potential savings on monthly utility bills. This model is not only cost-effective but also environmentally friendly, as it reduces energy consumption and lowers greenhouse gas emissions.

The Goodman SSZ 14 is equipped with an energy-efficient compressor that enhances its performance. The compressor operates quietly, which maintains a tranquil environment inside the home. Additionally, the sound-dampening features ensure that noise levels are kept to a minimum, providing homeowners with peace of mind while enjoying the comfort of their space.

This model features a durable construction designed to withstand diverse weather conditions. The coil is constructed from corrosion-resistant materials which prolong its lifespan and ensure reliability over time. Furthermore, the unit comes with a factory-installed filter drier that protects the refrigerant system by trapping contaminants and moisture, ensuring optimal operation.

Another key characteristic of the SSZ 14 SEER model is its environmentally responsible refrigerant. Goodman has transitioned to using R-410A refrigerant, which is known for being less harmful to the ozone layer compared to older refrigerants. This not only meets environmental regulations but also aligns with modern energy efficiency standards.

Installation flexibility is another advantage of the Goodman SSZ 14, as it is compatible with various home layouts. The unit can be installed in a range of configurations, making it easy to integrate into both new constructions and existing systems.

In summary, the Goodman Manufacturing SSZ 14 SEER model offers a blend of efficiency, durability, and versatility. With its energy-saving features, quiet operation, and long-lasting design, it stands out in the competitive landscape of heat pumps. Homeowners can trust the Goodman SSZ 14 to deliver comfort while promoting energy conservation and environmental responsibility.