6.3 Temperature Adjustment

6.3.1Manual Adjustment

Use this adjustment mode to set the temperature manually. To place the controller in this mode, press Auto/Man so that disappears

from the screen and set the temperature using the buttons.

NOTE: If the controller is in automatic heat/cool changeover, the setpoint is automatically lowered or raised by 1°C (2°F) when the controller switches to heating mode or to cooling mode respectively. For example, if you place the setpoint at 24°C (75°F) while in heating mode, the setpoint will become 25°C (77°F) in cooling mode and will return to 24°C (75°F) when the controller switches back to heating mode.

6.3.2Automatic Adjustment

Use this adjustment mode if you want the controller to automatically adjust the temperature according to the programmed schedule. To place the controller in this mode, press Auto/Man so that appears on the screen.

Pre-programmed Schedule

The following schedule has been programmed at the factory. Two temperature settings are programmed for each period of the sched- ule: one is used in heating mode and the other in cooling mode.

NOTE: When programming the heating setpoint, it cannot be higher than 1°C (2°F) below the cooling setpoint. For example, if the cooling setpoint is 25°C (77°F), the highest you can place the heating setpoint is 24°C (75°F). Conversely, when programming the cooling setpoint, it cannot be lower than 1°C (2°F) above than the heating setpoint.

Pre-programmed Schedule

MO

TU

WE

TH

FR

SA

SU

 

 

 

 

 

 

 

 

 

 

P1

Heating

21°C (70°F)

 

 

6:00 a.m.

 

 

 

 

 

 

 

 

Cooling

25.5°C (78°F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2

Heating

16.5°C (62°F)

 

8:00 a.m.

--

 

 

 

Cooling

29.5°C (85°F)

 

 

 

 

 

 

 

 

P3

Heating

21°C (70°F)

 

6:00 p.m.

--

 

 

 

Cooling

25.5°C (78°F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4

Heating

16.5°C (62°F)

 

 

10:00 p.m.

 

 

 

 

 

 

 

 

Cooling

28°C (82°F)

 

 

 

 

 

 

 

 

 

 

 

Modifying the Schedule

You can program up to 4 periods per day. For each period, you can set the start time, the heating mode setpoint and the cooling mode setpoint. The program can be different for each day of the week.

Press Pgm to enter the programming mode. The settings for

 

Monday, Period 1 (P1) appear.

To select a day to program, press Day until the day is dis-

 

played. Press Day for 3 seconds to select all 7 days.

 

NOTE: If you select all 7 days, the settings of the displayed period will

 

be copied to all 7 days. For example, if period 1 is displayed and you

 

then select all 7 days , they will all now have the same settings for

 

period 1. If you display period 2 while all 7 days are selected, they will

 

all now have the same settings for period 2.

Press to exit.

The following diagram shows how to navigate the programming menu.

 

 

MO

 

 

TU

 

 

 

6:00

 

 

6:00

 

P1

 

Pgm

Day

P1

Pgm

 

 

 

 

 

 

 

Heat

Mode

Cool

Heat

Mode

Cool

 

21

25.5

21

25.5

 

 

 

 

 

Pgm

 

 

Pgm

 

 

 

MO

 

 

TU

 

 

 

8:00

 

 

8:00

 

P2

 

Pgm

Day

P2

Pgm

 

 

 

 

 

 

 

Heat

Mode

Cool

Heat

Mode

Cool

 

16.5

29.5

16.5

29.5

 

 

 

Temporary Bypass

When you modify the temperature setpoint while the controller is in automatic mode, the new temperature is used for the next 2 hours.

The icon flashes during the bypass. After the bypass, the temperature set for the current period is used.

6.4 Unoccupied Mode

The controller can be placed in unoccupied mode via a remote con- trol device such as Aube’s CT241 telephone controller (see section 2.10). In this mode, the setpoint is set back by 4.5°C (8°F); it is low- ered in heating mode or raised in cooling mode. The message UNOC appears during the unoccupied mode.

NOTE: Automatic changeover is disabled during the unoccupied mode.

Temporary Bypass

In unoccupied mode, only the buttons work. When you adjust the temperature during this mode, the new temperature will be used for the next 2 hours, after which the controller will return to the previ- ous setpoint. The message UNOC flashes during the bypass.

7.Humidity Setting

7.1 Display

• To set the start time of a period, first press Pgm until the period

number (P1 to P4) is displayed and the time display flashes.

Then press the

buttons. The time changes in increments of

15 minutes.

 

NOTE: During programming, to skip a period press Clr while the period

is selected. For example, in the pre-programmed schedule, periods 2

and 3 have been skipped for Saturday and Sunday.

• To set the temperature for a period, first press Pgm until the

period number (P1 to P4) is displayed and the temperature dis-

play flashes. Then press Mode to select the heating mode set-

point display or the cooling mode setpoint. Finally press the

buttons.

 

The arrow appears when the humidity setpoint is displayed

Humidity level

Humidifier is On

Humidity control mode (auto, manual or off)

TH146-P-DE

400-280-004-C

11/29/06

8/9

Image 8
Contents Introduction InstallationInstallation Guide Configuration Principles of Operation Configuration Menu Connection Diagram New Installation TH146-PCT280-HP-2H1C Dual Energy AC144-03 CT241Connection Diagram Add-on Installation TH146-P Transformer AC146-410Dual Energy AC144-03 RC845 Auxiliary Heating SystemUser’s Guide General SettingTemperature Setting Unoccupied Mode Humidity SettingTemperature Adjustment Technical Specifications WarrantyHumidity Adjustment Support