7.2 Humidity Adjustment

Manual Adjustment

In manual adjustment, the humidity level is set by the user (5% to 60%).

nPress the Hum button until MAN appears on the screen.

oPress one of the buttons to adjust the humidity level.

pPress the button to return to normal display.

Automatic Adjustment

In automatic adjustment, the humidity level is set by the controller based on the outdoor temperature to prevent ice formation or con- densation on the windows while providing enough humidity for your comfort. However, the user can apply an offset (-9% to 9%). For example, the user can enter a negative offset if there is still ice for- mation or condensation on the windows.

nPress the Hum button until AUTO appears on the screen. The current humidity level set by the controller is also displayed.

oPress one of the buttons to place or modify the offset. p Press the button to save and exit the programming.

Off

To turn off the humidity control:

n Press the Hum button until OFF appears on the screen.

oPress the button to save and exit the programming.

8.Technical Specifications

CT280-HP-2H1C Control Module

Power supply: 24 VAC

Current consumption: 150 mA

Maximum load per output: 1 A @ 24 VAC

Short cycle protection: 2 minutes

Control cycles: 2 to 6 per hour

Operating temperature: 0°C to 50°C (32°F to 122°F)

Storage temperature: -20°C to 50°C (-4°F to 122°F)

Humidity conditions: 0% to 95%, non-condensing

Dimensions: 76 mm x 109 mm x 25 mm (3 in. x 4.3 in. x 1 in.)

TH146-P Console

Temperature setpoint range

Heating mode: 5°C to 30°C (40°F to 86°F)

Cooling mode: 15°C to 40°C (59°F to 104°F)

Humidity setpoint range: 5% to 60%

Indoor temperature display range: 0°C to 70°C (32°F to 158°F)

Outdoor temp. display range: -50°C to 70°C (-58°F to 158°F)

Temperature display resolution: 0.5°C (1°F)

Program protection: non-volatile memory

Operating temperature: 0°C to 50°C (32°F to 122°F)

Storage temperature: -20°C to 50°C (-4°F to 122°F)

Humidity conditions: 0% to 95%, non-condensing

Dimensions: 79 mm x 79 mm x 24 mm (3.1 in. x 3.1 in. x 1 in.)

9. Warranty

Aube warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and ser-

vice, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Aube shall repair or replace it (at Aube's option).

If the product is defective,

(i)return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or

(ii)contact Aube. Aube will make the determination whether the product should be returned, or whether a replacement product can be sent to you.

This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Aube that the defect or mal- function was caused by damage which occurred while the product was in the possession of a consumer.

Aube's sole responsibility shall be to repair or replace the product within the terms stated above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCI- DENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WAR- RANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some provinces and states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.

THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANT- ABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. Some provinces and states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

This warranty gives you specific legal rights, and you may have other rights which vary by province or state.

10.Support

If you have any questions about the product installation or opera- tion, or concerning the warranty, contact us at the address shown below.

705 Montrichard

10, rue Ampère

Saint-Jean-sur-Richelieu, Quebec

95500 Gonesse

J2X 5K8

France

Canada

Tel: 33 (0) 1 34 07 99 00

Tel: (450) 358-4600

Fax: 33 (0) 1 34 07 99 19

Toll-free: 1-800-831-AUBE

Email: advaube@comintes.com

Fax: (450) 358-4650

 

Email: aube.service@honeywell.com

 

For more information on our products, visit us at:

www.aubetech.com

As an ENERGY STAR® partner, Aube Technologies

has determined that this product meets the ENERGY STAR guidelines for energy efficiency.

TH146-P-DE

400-280-004-C

11/29/06

9/9

Image 9
Contents Installation Installation GuideIntroduction Configuration Principles of Operation Configuration Menu TH146-P Connection Diagram New InstallationCT280-HP-2H1C Dual Energy AC144-03 CT241TH146-P Transformer AC146-410 Connection Diagram Add-on InstallationDual Energy AC144-03 RC845 Auxiliary Heating SystemGeneral Setting Temperature SettingUser’s Guide Humidity Setting Temperature AdjustmentUnoccupied Mode Warranty Technical SpecificationsHumidity Adjustment Support