TABLE 3

OPTIONAL FIELD INSTALLED HEATER PACKAGES

ONLY TO BE USED WITH THE MODELS INDICATED

Heater Package

Volts &

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Phase

PA13241-A

PA13301-A

PA13361-A

PA13361-B

PA13422-A

PA13422-B

PA13422-C

PA13482-A

PA13482-B

PA13482-C

PA13602-A

PA13602-B

PA13602-C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EHP313-A05

240/208-1

X

X

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EHP313-A10

240/208-1

X

X

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EHP313-A15

240/208-1

 

X

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EHP313-B09

240/208-3

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EHP313-B15

240/208-3

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EHP513-A05

240/208-1

 

 

 

 

X

 

 

X

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EHP513-A10

240/208-1

 

 

 

 

X

 

 

X

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EHP513-A15

240/208-1

 

 

 

 

X

 

 

X

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EHP513-B09

240/208-3

 

 

 

 

 

X

 

 

X

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EHP513-B15

240/208-3

 

 

 

 

 

X

 

 

X

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EHP513-C09

460-3

 

 

 

 

 

 

X

 

 

X

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EHP513-C15

460-3

 

 

 

 

 

 

X

 

 

X

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 6
Contents Installation Instructions Single Package AIR Conditioners Contents Getting Other Information and Publications For More INFORMATION, Contact These PublishersShipping Damage Field Installed Heater Packages OptionalGeneral Instructions GeneralElectrical Specifications Hz Circuit aVolts Optional Field Installed Electric Heater Table Unit Dimension Chart Dimensions of UnitsLocation InstallationTypical Installations GeneralAirflow and Service Access Clearances Slab Mounting AT Ground LevelElevated Mounting Platform AS RequiredFilter Requirements & Sizes Condensate Drain TrapAIR Filters Condensate Drain TrapTransformer Taps Wiring Main PowerWiring 24V LOW Voltage Control Circuit ThermostatsLow Voltage Wiring LOW Voltage WiringTopping OFF System Charge Safety PracticesStart UP Start UP NotesSequence of Operation Three Phase Scroll Compressor Start UP InformationStart UP and Operation Indoor Blower MotorAdjustments LOW Ambient ControlPressure Service Ports Service and TroubleshootingService Hints FAN Blade Settings115 120 Pressure TableReturn Air Pressure Model120 125 Model 563Brazing Diagram Suction and Discharge Tube BrazingTroubleshooting GE ECM 2.3 Motors Troubleshooting GE ECM2.3 Motors CONT’D Troubleshooting GE X13-SERIES ECM2.3 Motors Troubleshooting GE X13-SERIES ECM2.3 Motors CONT’D

PA13361-B, PA13301-A, PA13241-A, PA13361-A specifications

The Bard PA13361-B, PA13361-A, PA13241-A, and PA13301-A are high-efficiency packaged air conditioning units known for their exceptional performance in residential and commercial settings. These models are designed to provide effective cooling solutions while maximizing energy efficiency and comfort.

One of the standout features of these models is their robust construction, made to withstand varying environmental conditions. The units are engineered with corrosion-resistant materials, making them ideal for both indoor and outdoor applications. This durability ensures that they can operate effectively in diverse climates, providing consistent cooling performance year-round.

The PA13361-B and PA13361-A models are equipped with advanced thermostatic control systems that allow for precise temperature adjustments. This technology enhances user comfort and contributes to energy savings by ensuring the system operates only when needed. Users can easily manage their indoor environment through intuitive controls, making it straightforward to tailor the cooling output to their preferences.

In terms of energy efficiency, these Bard units are designed to operate at low energy consumption levels while delivering powerful cooling capabilities. The integration of high-efficiency compressors and refrigerants contributes substantially to reducing energy costs, making these models an environmentally friendly choice for consumers. With a high Seasonal Energy Efficiency Ratio (SEER), these air conditioning units not only comply with but often exceed industry standards.

The PA13241-A and PA13301-A models introduce enhanced airflow technology, which allows for better air distribution throughout the space. This feature ensures that every corner of the room receives adequate cooling, eliminating hot spots and ensuring comfort for occupants.

Furthermore, the simplicity of installation and maintenance adds to the appeal of these models. Bard units are designed with serviceability in mind, allowing technicians to perform routine maintenance with ease. This accessibility can lead to reduced downtime and enhanced longevity of the equipment.

In summary, the Bard PA13361-B, PA13361-A, PA13241-A, and PA13301-A packaged air conditioning units are robust, efficient, and user-friendly systems. Their advanced features, energy-efficient operation, and durable construction make them a top choice for those seeking reliable cooling solutions in various settings. Whether for residential or commercial use, these models offer performance and comfort that users can depend on.