Bard W17L1, W24L1, W24A1, W30A1, W18L1, W18A1, W17A1, W48A1, W60A1, W60L1, W42A1, W36A1, W30L1 Electric Heat

Page 23

TABLE 8

ELECTRIC HEAT

Models

240V-1

208V-1

240V-3

208V-3

460V-3

 

 

 

 

 

 

 

 

 

 

 

KW

Amps

BTUH

Amps

BTUH

Amps

BTUH

Amps

BTUH

Amps

BTUH

 

 

 

 

 

 

 

 

 

 

 

4

16.7

13650

14.4

10240

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

20.8

17065

18.1

12800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

14.4

20500

12.5

15360

7.2

20500

 

 

 

 

 

 

 

 

 

 

 

8

33.3

27300

28.8

20475

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

21.7

30600

18.7

23030

10.8

30700

 

 

 

 

 

 

 

 

 

 

 

10

41.6

34130

36.2

25600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

14.4

40950

 

 

 

 

 

 

 

 

 

 

 

15

62.5

51250

54.0

38400

36.2

51200

31.2

38400

18.0

51200

 

 

 

 

 

 

 

 

 

 

 

18

 

 

 

 

43.3

61430

37.5

46100

 

 

 

 

 

 

 

 

 

 

 

 

 

20

83.2

68260

72.1

51200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual

2100-508F

Page

23 of 25

Image 23
Contents Bard Manufacturing Company, Inc Contents For More INFORMATION, Contact These Publishers Getting Other Information and PublicationsAIR Conditioner Wall Mount Model Nomenclature Shipping DamageGeneral Condensate Drain Duct WorkFilters Fresh AIR IntakeMounting the Unit Wall Mounting InformationLeft Unit Rightw Unit508F Manual Mounting InstructionsMounting Instructions Electric Heat Clearance If Required Wall Mounting InstructionsFree AIR Flow Ducted Supply No Duct Return AT Unit Common Wall Mounting InstallationsTAP Range Wiring Main PowerWiring LOW Voltage Wiring Topping OFF System Charge Safety PracticesPhase Monitor Important Installer NoteHigh Pressure Switch Three Phase Scroll Compressor Start UP InformationCompressor Control Module Pressure Service PortsSequence of Operation Refrigerant Charge FAN Blade Setting DimensionsFAN Blade Setting FAN Blade Dimension100 105 110 115 120 Cooling Pressure TableElectrical Specifications W**A Series Electrical Specifications W**L Series Maximum ESP of Operation Electric Heat only Recommended AirflowIndoor Blower Performance Electric Heat Kits Optional AccessoriesW17, W18, W24 W30, W36 W42, W48, W60, W70 Vent & Control Options
Related manuals
Manual 25 pages 23.65 Kb Manual 25 pages 48.6 Kb

W30A1, W18L1, W30L1, W17L1, W36A1 specifications

The Bard range of products, specifically the W24L1, W48L1, W42L1, W70A1, and W60A1 models, showcases advanced engineering aimed at providing efficient heating and cooling solutions. Each model comes with distinctive features and technologies tailored to meet various residential and commercial needs.

Starting with the W24L1 model, it is designed for compact spaces while delivering powerful performance. Its heating capacity is optimal for smaller areas, making it suitable for residential applications. The W24L1 incorporates advanced inverter technology, ensuring energy efficiency and reducing operational costs. This model is equipped with a user-friendly interface, enabling easy control and monitoring of settings.

Next is the W48L1, which offers increased capacity for larger spaces. This model is characterized by its robust build and enhanced airflow system that ensures uniform heating and cooling throughout the environment. The W48L1 utilizes environmentally friendly refrigerants, highlighting Bard’s commitment to sustainability. Its smart technology integration allows for seamless compatibility with smart home systems, providing added convenience for users.

The W42L1 model stands out for its versatility in both heating and cooling applications. It is engineered with high-efficiency components, which contribute to lower energy consumption. Features like programmable thermostats and variable speed fans enhance user comfort and adjust to varying demand. The W42L1 also comes with a durable construction, ensuring longevity and reliability even in challenging conditions.

For those demanding even higher performance, the W70A1 model caters to significant heating and cooling requirements. This unit is designed to tackle extreme weather conditions and is often favored for industrial applications. The W70A1 employs advanced heat exchanger technology, improving efficiency and reducing energy loss. Moreover, its rugged design enables operation in harsh environments without compromising performance.

Lastly, the W60A1 represents a harmonious blend of efficiency and power. It is particularly well-suited for mid-sized applications, combining the best features from the other models. The W60A1 integrates sophisticated microprocessor controls that optimize performance while ensuring compatibility with emerging smart technology platforms. Its energy-efficient design means lower operating costs while delivering impressive comfort levels.

In summary, Bard's W24L1, W48L1, W42L1, W70A1, and W60A1 models are engineered to deliver superior heating and cooling solutions across a variety of environments. With a focus on energy efficiency, advanced technologies, and user-friendly interfaces, these models exemplify Bard's commitment to innovation and sustainability in climate control systems.