Bard W60L1, W24L1, W24A1, W30A1, W18L1, W18A1, W17L1, W17A1, W48A1, W60A1 Mounting Instructions, Manual

Page 9

 

 

 

 

 

 

FIGURE 3B

 

 

 

 

 

W30A1, W30L1, W36A1, W36L1

 

 

 

 

 

MOUNTING INSTRUCTIONS

 

A

B

C

D

E

SEAL WITH BEAD

 

OF CAULKING ALONG

 

 

 

 

 

 

REQUIRED DIMENSIONS TO MAINTAIN

 

 

 

 

 

ENTIRE LENGTH OF TOP.

1/4" MIN. CLEARANCE FROM

28 1/2

8 1/2

5 1/4

3 13/16

17 5/8

 

COMBUSTIBLE MATERIALS

 

 

 

 

 

 

REQUIRED DIMENSIONS TO MAINTAIN

 

 

 

 

 

TOP

RECOMMENDED 1" CLEARANCE FROM

30

10

4 1/2

4 9/16

16 7/8

 

COMBUSTIBLE MATERIALS

WALL

RAIN FLASHING

SUPPLIED

FOAM AIR SEAL

WALL STRUCTURE

Manual Page

C A C

D

Supply Opening

12"

12"

12"

 

 

 

 

Return Opening

 

12"

 

 

 

 

 

28"

 

 

 

 

 

 

 

 

12"

7

 

 

3"

1"

3

81 "

"

 

 

4"

 

 

8

 

 

 

Typ.

 

5"

 

 

 

 

 

 

 

 

 

 

 

 

4"

 

 

 

 

4

1

"

Typ.

 

4 21 "

 

 

2

 

 

 

B

HEATER ACCESS

PANEL

 

E

14"

1"

1/4" CLEARANCE ON ALL FOUR SIDES OF SUPPLY AIR DUCT IS REQUIRED FROM COMBUSTABLE MATERIALS

SUPPLY AIR

DUCT

RETURN AIR

OPENING

NOTES:

IT IS RECOMMENDED THAT A BEAD OF SILICONE CAULKING BE PLACED BEHIND THE SIDE MOUNTING FLANGES AND UNDER TOP FLASHING AT TIME OF INSTALLATION.

W*R UNIT SHOWN, W*L UNIT

CONTROLS AND HEATER ACCESS

IS ON OPPOSITE (LEFT) SIDE.

2100-508F 9 of 25

Wall Opening and Hole Location View

Right Side View

MIS-311 C

Image 9
Contents Bard Manufacturing Company, Inc Contents For More INFORMATION, Contact These Publishers Getting Other Information and PublicationsShipping Damage GeneralAIR Conditioner Wall Mount Model Nomenclature Filters Duct WorkFresh AIR Intake Condensate DrainMounting the Unit Wall Mounting InformationLeft Unit Rightw Unit508F Manual Mounting InstructionsMounting Instructions Electric Heat Clearance If Required Wall Mounting InstructionsFree AIR Flow Ducted Supply No Duct Return AT Unit Common Wall Mounting InstallationsWiring Main Power Wiring LOW Voltage WiringTAP Range Topping OFF System Charge Safety PracticesHigh Pressure Switch Important Installer NoteThree Phase Scroll Compressor Start UP Information Phase MonitorPressure Service Ports Sequence of OperationCompressor Control Module FAN Blade Setting FAN Blade Setting DimensionsFAN Blade Dimension Refrigerant Charge100 105 110 115 120 Cooling Pressure TableElectrical Specifications W**A Series Electrical Specifications W**L Series Recommended Airflow Indoor Blower PerformanceMaximum ESP of Operation Electric Heat only Electric Heat Kits Optional AccessoriesW17, W18, W24 W30, W36 W42, W48, W60, W70 Vent & Control Options
Related manuals
Manual 25 pages 23.65 Kb Manual 25 pages 48.6 Kb

W30A1, W18L1, W30L1, W17L1, W36A1 specifications

The Bard range of products, specifically the W24L1, W48L1, W42L1, W70A1, and W60A1 models, showcases advanced engineering aimed at providing efficient heating and cooling solutions. Each model comes with distinctive features and technologies tailored to meet various residential and commercial needs.

Starting with the W24L1 model, it is designed for compact spaces while delivering powerful performance. Its heating capacity is optimal for smaller areas, making it suitable for residential applications. The W24L1 incorporates advanced inverter technology, ensuring energy efficiency and reducing operational costs. This model is equipped with a user-friendly interface, enabling easy control and monitoring of settings.

Next is the W48L1, which offers increased capacity for larger spaces. This model is characterized by its robust build and enhanced airflow system that ensures uniform heating and cooling throughout the environment. The W48L1 utilizes environmentally friendly refrigerants, highlighting Bard’s commitment to sustainability. Its smart technology integration allows for seamless compatibility with smart home systems, providing added convenience for users.

The W42L1 model stands out for its versatility in both heating and cooling applications. It is engineered with high-efficiency components, which contribute to lower energy consumption. Features like programmable thermostats and variable speed fans enhance user comfort and adjust to varying demand. The W42L1 also comes with a durable construction, ensuring longevity and reliability even in challenging conditions.

For those demanding even higher performance, the W70A1 model caters to significant heating and cooling requirements. This unit is designed to tackle extreme weather conditions and is often favored for industrial applications. The W70A1 employs advanced heat exchanger technology, improving efficiency and reducing energy loss. Moreover, its rugged design enables operation in harsh environments without compromising performance.

Lastly, the W60A1 represents a harmonious blend of efficiency and power. It is particularly well-suited for mid-sized applications, combining the best features from the other models. The W60A1 integrates sophisticated microprocessor controls that optimize performance while ensuring compatibility with emerging smart technology platforms. Its energy-efficient design means lower operating costs while delivering impressive comfort levels.

In summary, Bard's W24L1, W48L1, W42L1, W70A1, and W60A1 models are engineered to deliver superior heating and cooling solutions across a variety of environments. With a focus on energy efficiency, advanced technologies, and user-friendly interfaces, these models exemplify Bard's commitment to innovation and sustainability in climate control systems.