Bard 1 W48A1, W42L, W70L1, W70A1 installation instructions Wall Mounting Instructions

Page 12

FIGURE 5

WALL MOUNTING INSTRUCTIONS

SEE FIGURE 3 – MOUNTING INSTRUCTIONS

WALL STRUCTURE

 

 

FACTORY SUPPLIED

 

RAIN FLASHING.

 

MOUNT ON UNIT

 

BEFORE INSTALLATION

SUPPLY AIR

SUPPLY AIR

SUPPLY AIR

DUCT

OPENING

OPENING

 

RETURN AIR

RETURN AIR

RETURN AIR

OPENING

OPENING

OPENING

 

 

WOOD OR STEEL SIDING

BOTTOM MOUNTING

 

 

BRACKET. MOUNT ON

 

 

 

 

 

 

WALL BEFORE

 

 

 

INSTALLING UNIT.

 

CONCRETE BLOCK WALL INSTALLATION

WOOD FRAME WALL INSTALLATION

SIDE VIEW

MIS-548 A

FIGURE 6

WALL MOUNTING INSTRUCTIONS

ATTACH TO TOP

PLATE OF WALL

1.000" CLEARANCE ALL AROUND DUCT

IF REQUIRED

INTERIOR FINISHED WALL OVER FRAME

SEE UNIT DIMENSIONS, FIGURE 2, FOR ACTUAL DIMENSIONS.

E + 1.000

 

B

 

 

1.000

SUPPLY DUCT

A

OPENING

 

 

1.000" CLEARANCE

 

 

I

 

 

 

 

 

ALL AROUND DUCT

 

 

 

 

IF REQUIRED

 

 

 

 

 

RETURN DUCT

C

 

 

OPENING

 

 

 

 

 

 

EXTERIOR FINISH WALL

 

 

 

 

OVER FRAME

 

 

K

 

 

 

 

 

 

 

C

 

 

 

2 x 6

L

 

 

 

 

 

FRAMING MATERIAL

 

 

THIS STRUCTURAL MEMBER

2 x 4'S, 2 x 6'S &/OR

 

 

ATTACH TO BOTTOM

 

LOCATED TO MATCH STUD

STRUCTURAL STEEL

 

PLATE OF WALL

 

SPACING FOR REST OF WALL.

 

 

MIS-549 A

 

 

A SECOND MEMBER MAY BE

 

 

 

REQUIRED FOR SOME WALLS.

Manual

2100-508A

Page

12 of 25

Image 12
Contents Bard Manufacturing Company, Inc Contents Getting Other Information and Publications For More INFORMATION, Contact These PublishersShipping Damage GeneralAIR Conditioner Wall Mount Model Nomenclature Duct Work FiltersFresh AIR Intake Condensate DrainWall Mounting Information Mounting the UnitRight W Unit Left UnitMounting Instructions W30A1, W30L1, W36A1, W36L1 W42A1, W42L1, W48A1, W48L1, W60A1, W60L1, W70A1, W70L1 Electric Heat Clearance Wall Mounting Instructions Common Wall Mounting Installations Free AIR Flow Ducted Supply No Duct Return AT UnitWiring Main Power Wiring LOW Voltage WiringTAP Range Safety Practices Topping OFF System ChargeImportant Installer Note High Pressure SwitchThree Phase Scroll Compressor Start UP Information Phase MonitorPressure Service Ports Sequence of OperationCompressor Control Module FAN Blade Setting Dimensions Removal of FAN ShroudRefrigerant Charge Cooling Pressure Table 100 105 110 115 120Electrical Specifications W**A Series Electrical Specifications W**L Series Recommended Airflow Indoor Blower PerformanceMaximum ESP of Operation Electric Heat only Electric Heat Optional Accessories Vent & Control Options W18, W24 W30, W36 W42, W48, W60, W70
Related manuals
Manual 25 pages 32.94 Kb

W70A1, W70L1, W42L, 1 W48A1 specifications

The Bard range of products, specifically the W24L1, W48L1, W42L1, W70A1, and W60A1 models, showcases advanced engineering aimed at providing efficient heating and cooling solutions. Each model comes with distinctive features and technologies tailored to meet various residential and commercial needs.

Starting with the W24L1 model, it is designed for compact spaces while delivering powerful performance. Its heating capacity is optimal for smaller areas, making it suitable for residential applications. The W24L1 incorporates advanced inverter technology, ensuring energy efficiency and reducing operational costs. This model is equipped with a user-friendly interface, enabling easy control and monitoring of settings.

Next is the W48L1, which offers increased capacity for larger spaces. This model is characterized by its robust build and enhanced airflow system that ensures uniform heating and cooling throughout the environment. The W48L1 utilizes environmentally friendly refrigerants, highlighting Bard’s commitment to sustainability. Its smart technology integration allows for seamless compatibility with smart home systems, providing added convenience for users.

The W42L1 model stands out for its versatility in both heating and cooling applications. It is engineered with high-efficiency components, which contribute to lower energy consumption. Features like programmable thermostats and variable speed fans enhance user comfort and adjust to varying demand. The W42L1 also comes with a durable construction, ensuring longevity and reliability even in challenging conditions.

For those demanding even higher performance, the W70A1 model caters to significant heating and cooling requirements. This unit is designed to tackle extreme weather conditions and is often favored for industrial applications. The W70A1 employs advanced heat exchanger technology, improving efficiency and reducing energy loss. Moreover, its rugged design enables operation in harsh environments without compromising performance.

Lastly, the W60A1 represents a harmonious blend of efficiency and power. It is particularly well-suited for mid-sized applications, combining the best features from the other models. The W60A1 integrates sophisticated microprocessor controls that optimize performance while ensuring compatibility with emerging smart technology platforms. Its energy-efficient design means lower operating costs while delivering impressive comfort levels.

In summary, Bard's W24L1, W48L1, W42L1, W70A1, and W60A1 models are engineered to deliver superior heating and cooling solutions across a variety of environments. With a focus on energy efficiency, advanced technologies, and user-friendly interfaces, these models exemplify Bard's commitment to innovation and sustainability in climate control systems.