Bard 1 W48A1, W42L, W70L1, W70A1 installation instructions Mounting Instructions

Page 8

Page

Manual

8 of 25

2100-508A

3 1613 "

 

7 161 "

 

20"

7 161 "

 

 

 

Supply Opening

8"

 

 

 

 

12"

 

 

 

 

 

12"

 

 

 

 

20 21 "

 

 

 

 

 

12"

 

 

Return Opening

12"

12"

 

 

 

20"

 

 

 

 

 

 

12"

 

3"

 

3

81 "

7

"

1"

4"

1"

 

8

 

Typ.

5"

 

 

 

 

 

 

 

4"

 

 

 

 

Typ.

 

 

 

 

2"

 

2"

 

FIGURE 3A

W18A1, W18L1, W24A1, W24L1

MOUNTING INSTRUCTIONS

SEAL WITH BEAD

OF CAULKING ALONG

ENTIRE LENGTH OF TOP.

TOP

WALL

HEATER ACCESS

PANEL

RAIN FLASHING

SUPPLIED

FOAM AIR SEAL

WALL STRUCTURE

1/4" CLEARANCE ON ALL FOUR SIDES OF SUPPLY AIR DUCT IS REQUIRED FROM COMBUSTABLE MATERIALS

SUPPLY AIR

DUCT

RETURN AIR

OPENING

NOTES:

IT IS RECOMMENDED THAT A BEAD OF SILICONE CAULKING BE PLACED BEHIND THE SIDE MOUNTING FLANGES AND UNDER TOP FLASHING AT TIME OF INSTALLATION.

W**A UNIT SHOWN, W**L UNIT

CONTROLS AND HEATER ACCESS

IS ON OPPOSITE (LEFT) SIDE.

Wall Opening and Hole Location View

Right Side View

MIS-353 C

Image 8
Contents Bard Manufacturing Company, Inc Contents Getting Other Information and Publications For More INFORMATION, Contact These PublishersAIR Conditioner Wall Mount Model Nomenclature Shipping DamageGeneral Duct Work FiltersFresh AIR Intake Condensate DrainWall Mounting Information Mounting the UnitRight W Unit Left UnitMounting Instructions W30A1, W30L1, W36A1, W36L1 W42A1, W42L1, W48A1, W48L1, W60A1, W60L1, W70A1, W70L1 Electric Heat Clearance Wall Mounting Instructions Common Wall Mounting Installations Free AIR Flow Ducted Supply No Duct Return AT UnitTAP Range Wiring Main PowerWiring LOW Voltage Wiring Safety Practices Topping OFF System ChargeImportant Installer Note High Pressure SwitchThree Phase Scroll Compressor Start UP Information Phase MonitorCompressor Control Module Pressure Service PortsSequence of Operation Refrigerant Charge FAN Blade Setting DimensionsRemoval of FAN Shroud Cooling Pressure Table 100 105 110 115 120Electrical Specifications W**A Series Electrical Specifications W**L Series Maximum ESP of Operation Electric Heat only Recommended AirflowIndoor Blower Performance Electric Heat Optional Accessories Vent & Control Options W18, W24 W30, W36 W42, W48, W60, W70
Related manuals
Manual 25 pages 32.94 Kb

W70A1, W70L1, W42L, 1 W48A1 specifications

The Bard range of products, specifically the W24L1, W48L1, W42L1, W70A1, and W60A1 models, showcases advanced engineering aimed at providing efficient heating and cooling solutions. Each model comes with distinctive features and technologies tailored to meet various residential and commercial needs.

Starting with the W24L1 model, it is designed for compact spaces while delivering powerful performance. Its heating capacity is optimal for smaller areas, making it suitable for residential applications. The W24L1 incorporates advanced inverter technology, ensuring energy efficiency and reducing operational costs. This model is equipped with a user-friendly interface, enabling easy control and monitoring of settings.

Next is the W48L1, which offers increased capacity for larger spaces. This model is characterized by its robust build and enhanced airflow system that ensures uniform heating and cooling throughout the environment. The W48L1 utilizes environmentally friendly refrigerants, highlighting Bard’s commitment to sustainability. Its smart technology integration allows for seamless compatibility with smart home systems, providing added convenience for users.

The W42L1 model stands out for its versatility in both heating and cooling applications. It is engineered with high-efficiency components, which contribute to lower energy consumption. Features like programmable thermostats and variable speed fans enhance user comfort and adjust to varying demand. The W42L1 also comes with a durable construction, ensuring longevity and reliability even in challenging conditions.

For those demanding even higher performance, the W70A1 model caters to significant heating and cooling requirements. This unit is designed to tackle extreme weather conditions and is often favored for industrial applications. The W70A1 employs advanced heat exchanger technology, improving efficiency and reducing energy loss. Moreover, its rugged design enables operation in harsh environments without compromising performance.

Lastly, the W60A1 represents a harmonious blend of efficiency and power. It is particularly well-suited for mid-sized applications, combining the best features from the other models. The W60A1 integrates sophisticated microprocessor controls that optimize performance while ensuring compatibility with emerging smart technology platforms. Its energy-efficient design means lower operating costs while delivering impressive comfort levels.

In summary, Bard's W24L1, W48L1, W42L1, W70A1, and W60A1 models are engineered to deliver superior heating and cooling solutions across a variety of environments. With a focus on energy efficiency, advanced technologies, and user-friendly interfaces, these models exemplify Bard's commitment to innovation and sustainability in climate control systems.