I-Data FS 250 PDS Connecting the ida FS 250 to System, What if the CU Indicator fails to turn on?

Page 19

Connecting to System

ida FS 250, Operator's Guide

If the printout format does not match the test printout in Appendix B. or if nothing was printed, this means that the printer setup does not match the protocol converter setup. Contact your systems support personnel or your i-data dealer.

6.Power OFF and ON the ida FS 250 and check that all indicators light up momentarily.

7.Proceed to the chapter: Connecting ida FS 250 to System.

3.5.Connecting the ida FS 250 to System

After a successful test printout has been generated to establish that the connection between the ida FS 250 converter and the printeris working correctly (see previous section), you are now ready to connect the ida FS 250 to the system.

WARNING:

All connections to theida FS 250 protocol converter should be made while the power is switched OFF.

1.Turn off the power and connect the ida FS 250 to your host system using the twinax cable, and the auto-terminating T-cable.

2.When the connection has been made, tu rn power ON and check that the CU and READYindicators turn ON. When they do, you have completed the installation procedure and are ready to operate the protocol converter as described below.

What if the CU Indicator fails to turn on?

If the CU indicator does not turn ON, this means that there is no communication with the control unit. You should check the follow ing:

a.The twinax cable connection from the control unit to the ida FS 250.

b.The control unit (is it powered up etc.)

c.Is the control unit supported by the ida FS 250 ?

(See the section. Supported Control Units, for a list of sup ported control units).

-19-

Image 19
Contents Trademarks EMC directiveAbout i-data Ida FS 250 PDS PrefaceRelated Manuals SeptemberTable of Contents Ida FS 250, Operators Guide Table of Contents Table of Contents Ida FS 250, Operators Guide Kit Contents Non-IPDS Ida FS 250 Product FeaturesIntroduction to ida FS Introduction to ida FSIpds Supported Control UnitsNational Language Selection Installation RequirementsPre-Installation Requirements Environment requirementsOption Description Paper Size EU/US??% Y8,number of new language% selects languageRear Panel Installation and Connections of the ida FSSerial input Twinax Connector Emulation Via the Address SwitchY37,3812% Via the LineNon-IPDS Selection Emulation %Y37,5224%Y37,n1 Write Emulation Upgrading to IpdsConnecting via Centronics output Connecting the ida FS 250 to the PrinterConnecting via RS-232 output What if the CU Indicator fails to turn on? Connecting the ida FS 250 to SystemTest via the address switch TestingTimeout Ida FS 250 top panel Operation of ida FSPAR Parallel input Ready Printer Ready SER Serial input/outputState Indication Timeout string must be written in ONE line see example below Specifying Share Timeout and StringPage IdaSetup Ipds Programming Printer IRQ HandlingEscape Character Programming ida FS 250 non-IPDSInvalid Escape Character RecoveryDefining a Temporary Escape Character Syntax of an FSL FunctionDescription Setup Functions supported PCL ModeWhere % is the defined ESC character ESC FeaturesNo. Description Quick Reference Guide of Supported FSL Functions Name Syntax Parameters = COR N1 Physical paper Name Syntax Parameters Ipds String Ebcdic Name Syntax Parameters IBM Gfid APO Eeprom Activating the Y249 Engineering Function Programming via ShareportEscape sequences must be in HEX Updating firmwareIda FS 250 Error Messages Errors and RecoveryTwo Devices with Same Address Appendix a Use of ida FS 250 Serial Port Appendix B Test Printout Symbol SET and Translate Table Appendix C Default Gfid TableIBM Gfid Typeface PCL No Name of Typeface Style StrokeweightScalable Fonts Only applies to printers running PCL LevelFont examples Ipds Appendix D i-data Product PlatformSoftware Programmers Guide IndexReaders Comments

FS 250 PDS, FS 250, i-data Electronic Documentation ida specifications

I-Data, a prominent player in the electronic documentation and information management sector, has introduced its innovative solutions, namely the I-Data Electronic Documentation, the FS 250, and the FS 250 PDS. These products are designed to streamline document management processes, enhance efficiency, and ensure secure electronic documentation handling.

The I-Data Electronic Documentation system is built on a foundation of cutting-edge technologies that facilitate seamless integration into existing workflows. It provides an intuitive user interface, making it accessible for users with varying levels of technical expertise. One of its main features is the ability to capture, store, and retrieve documents electronically, dramatically reducing the volume of physical paperwork in organizations. With robust search functions, users can locate necessary documents quickly, saving valuable time.

The FS 250 is another remarkable product that complements the I-Data ecosystem. This high-performance document scanner is designed for efficiency, capable of handling large volumes of documents at rapid speeds. Key features of the FS 250 include its double-sided scanning capability, which allows users to scan both sides of a document in a single pass, thus optimizing productivity. Moreover, the FS 250 supports various document types, ranging from single-page sheets to multi-page booklets, further enhancing its versatility.

The FS 250 PDS (Professional Document Station) takes the functionalities of the FS 250 to the next level. It includes advanced processing capabilities that ensure scanned documents are not only captured but also enhanced before storage. This model features Optical Character Recognition (OCR) technology, enabling users to convert scanned images into editable and searchable text. This functionality is particularly valuable for organizations looking to digitize vast archives while maintaining data accuracy and accessibility.

In addition, both the FS 250 and FS 250 PDS are equipped with advanced security protocols to safeguard sensitive information. These models support encryption, secure user authentication, and access control, ensuring that only authorized personnel can view or modify documents.

Overall, the I-Data Electronic Documentation system along with the FS 250 and FS 250 PDS represent a significant advancement in electronic documentation solutions. With their focus on efficiency, security, and user-friendly design, these products offer organizations a means to modernize their document management processes, ultimately leading to enhanced productivity and streamlined operations. As the demand for digital solutions continues to grow, I-Data remains at the forefront of innovation in the electronic documentation landscape.