Stanley Black & Decker HD45 Cold Weather Operation, Underwater Model Preventative Maintenance

Page 11

OPERATION

COLD WEATHER OPERATION

If the drill is to be used during cold weather, preheat the hydraulic fluid at low engine speed. When using the normally recommended fluids, fluid temperature­ should be at or above 50 °F/10 °C (400 SSU/ 82 centistokes) before use.

Damage to the hydraulic system or drill can result from use with fluid that is too viscous or too thick.

UNDERWATER MODEL

PREVENTATIVE MAINTENANCE

After each use, the movable portions of the tool that were exposed to water should be flushed with a water displacing oil such as WD40®. Remove any remaining water and debris as follows:

1.Turn the tool upside down (without the tool bit) and spray oil through the drive hex and side holes in the motor assembly to displace any remaining water in the lower piston cavity.

2.Spray oil into the On/Off valve trigger slot area.

3.Dip or spray the entire tool.

4.Cycle the tool hydraulically several times before storing away.

HD45 User Manual ◄ 11

Image 11
Contents HD45 Weisbeck, Andy Declaration of ConformityTable of Contents Local Safety Regulations Safety SymbolsSafety Precautions Stanley Hydraulic tools Tool Stickers & TagsHose Types Hose Safety Tags Tool to Hydraulic Circuit Hose Recommendations Hose RecommendationsHtma / Ehtma Requirements Htma / Ehtma RequirementsDrill Operation Preoperation ProceduresBIT Installation OperationCold Weather Operation Underwater Model Preventative MaintenanceAccumulator Charging Accumulator Testing ProcedureGeneral Service Notes Charging the AccumulatorCharging the Accumulator Tool Protection & Care Problem Cause Solution TroubleshootingSpecifications AccessoriesHD45 Parts Illustration Part QTY Description HD45 Parts ListUnderwater Models only Underwater Tools Depth Guideline