Friedrich P/N9368987060-01 manual Temperature SET Back Timer, Temperature SET Back timer setting

Page 9

TEMPERATURE SET BACK TIMER

Temperature SET BACK timer setting

1

SET BACK

SU MO TU WE TH FR SA

3 6 9 12 15 18 21

Press the SET BACK button to change to the SET BACK con- firmation display.

The SET BACK operating time and the set temperature will be displayed.

If there is no existing SET BACK tempera- ture setting, “- -” will be displayed for the temperature.

2 SET

Press the SET button for 2 seconds or more.

3

Day setting

 

Operating time setting

 

 

 

 

 

 

 

 

 

SU MO TU

WE TH FR SA

 

DAY

SET

SET

 

 

 

 

 

 

DAY OFF

 

 

 

3

6

9

12 15 18 21

 

2

 

4

ex. When setting all days together

 

1

3

Follow the same procedures to set the operating time as those for the weekly timer. The DELETE button is also used as described in the procedures for the weekly timer.

4

Temperature setting

Press the SET TEMPERATURE buttons to

 

set the temperature (from 64 °F to 88 °F).

 

 

SU MO TU WE TH FR SA

 

 

 

 

3

6

9

12 15 18 21

SET BACK

ON

84°F

OFF

ex. Operating time 3:00–10:00 P.M.

temperature

76°F

 

 

(15:00–22:00)

Normal

 

 

76°F

 

 

 

temperature

 

 

 

 

 

 

 

5

SET

Repeat steps 3 and 4. Press the SET button for 2 seconds or more to com- plete the temperature SET BACK timer settings.

Temperature SET BACK timer operation

To start

SET BACK

SU MO TU WE TH FR SA

ex. Display during SET BACK timer operation (The operating time will not be displayed.)

Press the SET BACK button. The SET BACK confirmation display appears for 5 seconds, and then the timer starts automatically.

To cancel

SET BACK

DELETE

1

2

Press the SET BACK button, and then press the DELETE button while the SET BACK confirmation display is dis- played. Even if the SET BACK button is pressed again, the SET BACK timer will be cancelled.

NOTES

(1)The SET BACK timer only changes the set temperature, it cannot be used to start or stop air conditioner operation.

(2)The SET BACK timer can be set to operate up to two times per day but only one temperature setting can be used.

(3)The SET BACK timer can be used together with the ON, OFF, and weekly timer functions.

(4)The SET BACK operating time is displayed only in the SET BACK confirmation display. (Refer to step 1 for the SET BACK confirmation display.)

(5)The SET BACK operating time is displayed only in the SET BACK confirmation display. (Refer to step 1 for the SET BACK confirmation display.)

En-8

9368987060-01_OM_en.p65

8

2/4/10, 4:45 PM

Image 9
Contents Cassette Type Safety Precautions ContentsName of Parts Remote controllerPreparatory Operation To set the operation modeOperation Set the current day and timeRoom temperature sensor selection Energy savePart lock function ON/OFF Timer Timer FunctionsTo set the ON/OFF timer To cancelWeekly timer setting Day of the week settingTime setting Weekly timer operation Weekly TimerNormal Next day setting To set the DAY OFF for a holidayTemperature SET Back timer setting Temperature SET Back TimerTemperature SET Back timer operation Day setting Operating time settingOperating Tips Simultaneous Use of Multiple Units Multi-type Air conditionerTo adjust the vertical airflow direction Adjusting the Direction of AIR CirculationAirflow direction setting Range of swing Swing OperationCleaning the air filter Care and MaintenanceSELF-DIAGNOSIS How to cleaningSymptom Problem TroubleshootingMore Symptom Items to check9368987060-01OMes.p65 10, 448 PM 9368987060-01OMes.p65 10, 448 PM

P/N9368987060-01 specifications

Friedrich P/N9368987060-01 is a sophisticated, compact air conditioning unit designed to deliver efficient cooling and comfort in various indoor environments. Known for its reliability and innovative features, this model caters to both residential and light commercial applications, making it a versatile choice for many users.

One of the main features of the Friedrich P/N9368987060-01 is its impressive energy efficiency. It is equipped with advanced cooling technology that allows it to operate in an environmentally friendly manner while significantly reducing energy consumption. This not only helps lower electricity bills but also minimizes the unit's carbon footprint, aligning with modern sustainability goals.

The unit incorporates a powerful yet quiet compressor, providing optimal cooling performance without the disruptive noise levels often associated with traditional air conditioning systems. This feature makes it ideal for use in bedrooms, offices, or any space where a peaceful atmosphere is essential.

In terms of control and convenience, Friedrich has integrated a user-friendly digital display. This allows users to easily monitor and adjust settings, enhancing the overall experience. The unit also supports remote operation, so users can adjust the temperature or switch modes from anywhere in the room, further enhancing user convenience.

Friedrich P/N9368987060-01 comes with multiple cooling modes and fan speeds, offering customizable comfort for different situations. The cooling mode is perfect for hot summer days, while the fan-only mode is ideal for circulating air without additional cooling. Additionally, it features an energy-saving mode that automatically adjusts the temperature and fan speed based on current conditions, ensuring energy conservation without sacrificing comfort.

Further extending its appeal, the unit is designed with enhanced air filtration technology. A high-quality filter captures dust, allergens, and other airborne particles, contributing to improved indoor air quality. This feature is essential for maintaining a healthy living environment, particularly for those with allergies or respiratory conditions.

Overall, the Friedrich P/N9368987060-01 stands out in the air conditioning market for its blend of efficiency, technology, and user-centric design. With its commitment to performance and comfort, this model is a reliable choice for anyone looking to enhance their indoor climate experience.