Lincoln Electric SA-250 manual Optional Features

Page 9

OPTIONAL FEATURES

Power Plug Kit (K802C)

Accessory Set (K703)

Includes electrode and work cables, headshield, work clamp, and electrode holder.

Ether Start Kit (K793-1) for Perkins Engine

When frequent starting is expected below 10°F (-12°C), remove the thermostartsystem and install the optional ether start kit to provide maximum cold weather starting assistance. Note: The required ether tank is not provided with the kit and must be pur- chased locally. Ether starting should only be used as required since indiscriminate application will contribute to shortened engine life. (Available for field installation

only).

A power plug kit for the auxiliary power receptacles is available. (Provides a plug for each receptacle).

Trailer (K913)

Two-wheeled highway trailer with steel, torsion-bar axle, 54(137cm) wheel track. Low sway, low center- of-gravity. Sturdy tread plate platform. Choice of 3 hitches. Add on fender & light package. For highway use, consult applicable local laws regarding possible additional requirements.

Order: K913-1 Base Trailer

K913-2 Ball Hitch

K913-3 Lunette Eye Hitch

K913-4 Clevis Pin Hitch

K913-5 Fender & Light Kit

Hi-Freq(K799)

Provides high frequency plus gas valve for DC TIG welding. (Request Publication E385).

Optional field installed water valve kit available. Order

K844.

Linc-Thaw(L2964-5) Control Unit

Includes meter and fuses to protect welder when thawing frozen water pipes.

WARNING

Pipe Thawing IS NOT a CSA approved procedure. If not done properly, it can result in fire, explosion, damage to wiring which may make it unsafe, dam- age to pipes, burning up the welder, or other haz- ards.

Do not use a welder to thaw pipe before reviewing Lincoln Bulletin E695.1 (dated October 1987 or later.)

------------------------------------------------------------------------

Mufflers

Mufflers are standard on the SA-250 Perkins.

Wire Feed Module (K623-1)

The Wire Feed Module is field-installed on the K1283-4, and factory-installed on the K1283-5 to provide CV (constant voltage) output for semiautomatic welding. Output rated at 250 Amps at 35 Volts with a 60% Duty Cycle and 310 Amps at 32 Volts with a 35% Duty Cycle.

DIMENSIONS

See dimension Print M8869-24 at the rear of this man- ual.

8

Image 9
Contents SA-250 Perkins Safety Electric Shock can kill Safety Sûreté Pour Soudage a L’Arc Précautions DE SûretéPlease Examine Carton and Equipment For Damage Immediately Thank YouTable of Contents Design Summary General DescriptionOptional Features Machine SpecificationsPRE-OPERATION Installation Polarity Control & Cable Sizes PRE-OPERATION Service Engine Operation Starting the Perkins D3.152 EngineStopping the Perkins D3.152 Engine Duty Cycle Welder OperationControl of Welding Current Idler OperationMaintenance Commutator & Brushes BearingsTroubleshooting Idler MaintenanceNameplates Trouble Cause What to do Flashing the Fields AC Auxiliary PowerElectronic Idler Troubleshooting Guide SA-250 & 350-SA Dimension Print Page How To Read Shop Drawings New Lessons in Arc WeldingNeed Welding Training? Precaucion Warnung
Related manuals