Lincoln Electric IM526-B manual Meter Polarity Switch, Auxiliary Power, Routine Maintenance

Page 13

Meter Polarity Switch

The wire feeder polarity switch is located at the rear of the machine. The switch provides a work connection for wire feeder voltmeters. Place the switch in the position of the electrode polarity indicated by the decal. The switch does not change the welding polarity.

T 1 3 0 8 6 - 8 4

Auxiliary Power

A 24 VAC @ 1 amp supply is included for use with the LN-25 wire feeder (24 volts needed for K431 and K432 options). This supply is protected by a self- resetting current limiter.

A 42 VAC @ 5.5 amp supply is included for use with other wire feeders. This supply is protected by a 6 amp breaker located on the rear of the machine.

A 110/115 VAC @ 2 amp supply is included for use with the LN-7 or LN-9 GMA wire feeders. This supply is protected by a 2.5 amp breaker located on the rear of the machine. It is NOT available on IEC units.

All three supplies are not to be loaded simultaneously.

MAINTENANCE

WARNING

ELECTRIC SHOCK can kill.

Have an electrician install and service this equipment.

Turn the input power off at the fuse box before working on equipment.

Do not touch electrically hot parts.

---------------------------------------------------------------------

EXPLODING PARTS can cause

injury.

• Failed parts can explode or cause other parts to explode when power is applied.

Always wear a face shield and long sleeves when servicing.

----------------------------------------------------------------------------------

Capacitor Discharge Procedure

1.Obtain a power resistor (25 ohms, 25 watts).

2.Hold resistor body with electrically insulated glove. DO NOT TOUCH TERMINALS. Connect the resis- tor terminals across the two hex head cap screws in the position shown. Hold in each position for 1 second. For 575 VAC only, repeat for second capacitor. Repeat for the capacitor(s) on the other side of the machine

RESISTOR

CAPACITOR

TERMINALS

3.Use a DC voltmeter to check that voltage is not present across either capacitor.

Routine Maintenance

1.Every 6 months or so the machine should be cleaned with a low pressure airstream. Keeping the machine clean will result in cooler operation and higher reliability. Be sure to clean these areas:

Power, switch, driver, protection and control printed circuit boards.

Power switch

Main transformer

Input rectifier (located in front of fan blade)

Heat sink fins

2.Examine the sheet metal case for dents or breakage. Repair the case as required. Keep the case in good con- dition to insure that high voltage parts are protected and correct spacings are maintained. All external sheet metal screws must be in place to insure case strength and electrical ground continuity.

13

Image 13
Contents INVERTECV300-PRODecember,1999 Safety Depends on YouElectric Shock can kill Electric and Magnetic Fields Précautions DE Sûreté Table of Contents Please Examine Carton and Equipment For Damage Immediately Installation SpecificationsProduct Description Three Phase Input Single Phase InputLN-25 Connection Instructions LN-7 Connection InstructionsParallel Operation Remote Control of InvertecK900-1 DC TIG Starter Connection Output Cables LN-9 GMA Connection InstructionsQuick Disconnect Plugs Operating Instructions Mode SwitchArc Force / Inductance Control Output Terminals SwitchMeter Polarity Switch MaintenanceAuxiliary Power Capacitor Discharge ProcedureTroubleshooting Periodic MaintenanceTrouble What To Do Troubleshooting GuideNext Test Step Check Result Conclusion Repair Action Test ProceduresNext Test Next Step Test Conclusion Repair Action Check Result Next Step Test Matched Parts Switch PC Board Replacement ProcedureTest After Repair Printed Circuit Board Replacement Replacement of Power Modules and Output DiodesComponent to Heat Sink Component Torque ±10%P O W E R S O U R C E Remote Control AdaptersInstallation I N S T R U C T I O N S K867 Universal Adapter for 14-PIN Wire Feeder ReceptacleT I O N a L O N T R O L B L EV E R T E C W E R S O U R C E P H E N O L R K A R ET U S E D O N I N V E R T E C V E R T E CN N E C T T O G E T H E R F O R L D I N G O U T P U T M O T E O U T P U T C O N T R O LN T R O L C a B L E P H E N O L R KE C T R O D E C a B L E N T R O LP H E N O L N D a M P T R O LR C H K900-1 DC TIG Starter Connection DiagramLN-9 GMA with K596 Cable to Invertec Connection Diagram E C T R O D E C a B L E Wiring Diagram V300-PRO Code 10256, V300-I Code Wiring Diagram V300-PRO Code 10257 Invertec V300-PRO Invertec V300-PRO Invertec V300-PRO $700.00 How To Read Shop DrawingsPrecaucion Warnung