Lincoln Electric IM692 manual Contact your local Lincoln Authorized Field Service Facility

Page 15

E-2

 

TROUBLESHOOTING

 

E-2

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

Machine input contactor does not

1. Supply line fuse is blown.

operate.

2. Contactor power circuit has an

(White Power light off)

 

open lead.

 

3.

Broken power lead.

 

4.

T2 internal thermal breaker open

 

5. Defective POWER ON/OFF

 

 

Switch (S1).

 

7.

Control circuit diode bridge open

 

8.

Transformer iron rear thermostat open.

 

 

(White Power light on)

1. Open input contactor coil.

 

2.

Defective Control Board.

 

3.

Contactor moving iron binding.

 

 

Machine input contactor operates,

1. Electrode or work lead loose or

but no output when trying to weld.

 

broken.

 

2. Open main transformer (T1) pri-

 

 

mary or secondary circuit.

 

3. Firing P.C. board not connected

 

 

or is faulty.

 

4.

Firing board not getting enable

 

 

signal.

 

 

Machine does not have maximum

1. One input fuse blown.

output.

2. One phase of main transformer

 

 

(T1) open.

 

3.

Faulty Control or Firing P.C.

 

 

boards.

 

4.

Faulty SCR bridge.

 

5.

Input voltage too low.

 

 

Machine has output only momentarily

1. Machine has either an internal or

after contactor closes.Output returns

 

external short circuit on the output.

momentarily every 75 seconds.

2. Faulty Control PC board.

 

 

Machine has output only momen-

1. Output voltage peaks are too

tarily, contactor opens immediately

 

high because input voltage too

after closing. (Green Safe Output

 

high.

light off)

2. Output voltage peaks are too

 

 

high because output filter circuit

 

 

not working.

 

3.

Output voltage peaks are too

 

 

high because control circuit isn’t

 

 

sensing output voltage.

 

4.

Control board faulty.

 

5.

Output SCR shorted.

 

 

 

Machine output doesn’t stay on.

 

 

(Amber Thermal light on, fan run-

1. Machine is overloaded.

ning, digital Output display reads

 

 

greater than 100).

 

 

 

 

 

If all recommended possible areas of misadjustment have been checked and the problem persists,

Contact your local Lincoln Authorized Field Service Facility.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

MULTI-SOURCE

Image 15
Contents MULTI-SOURCE California Proposition 65 Warnings SafetyElectric Shock can kill Cylinder may explode if damaged Sûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Technical Specifications Multi-Source K1752-1 InstallationLocation StackingInput and Grounding Connetions Recommended Equipment and Processes Output CABLES, Connections and LimitationsGeneral Description Safety PrecautionsDesign Features ALL Models OperationAccessories Machine Calibration Specification MaintenanceRoutine Maintenance Periodic MaintenanceHOW to USE Troubleshooting Guide TroubleshootingContact your local Lincoln Authorized Field Service Facility Troubleshooting PC Board Troubleshooting Guide Firing P.C. Board PC Board Troubleshooting Guide Control P.C. Board Diagrams MULTI-SOURCE Wiring DiagramMULTI-SOURCE Dimension Print Page Page How To Read Shop Drawings Precaucion Warnung