TROUBLESHOOTING

 

E-3

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

Machine output doesn’t stay on.

1. Cooling air blocked or limited.

(Amber Thermal light on, fan run-

2. Faulty output lead thermostat,

ning, digital Output display never

 

SCR heat sink thermostat or

reads greater than 100)

 

connecting leads.

 

3.

Ambient cooling air too hot.

 

 

Machine output doesn’t stay on.

1. Faulty cooling fan or wiring.

(Amber Thermal light on, fan not

2. Faulty wiring in shunt circuit.

running, digital Output display

 

(Digital Output display reads

never reads over 100)

 

near zero.)

 

3.

Faulty Control board.

 

4.

115 Vac winding on main trans-

 

 

former not providing voltage.

 

5.

Fan circuit breaker on front con-

 

 

trol panel is tripped.

 

 

Machine will not shut off.

1. Input contactor (CR1) contacts

 

 

are frozen.

 

2.

Defective POWER switch (S1).

 

 

 

 

 

 

If all recommended possible areas of misadjustment have been checked and the problem persists,

Contact your local Lincoln Authorized Field Service Facility.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

MULTI-SOURCE

Image 16
Contents MULTI-SOURCE Safety California Proposition 65 WarningsElectric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Installation Technical Specifications Multi-Source K1752-1Stacking LocationInput and Grounding Connetions Output CABLES, Connections and Limitations Recommended Equipment and ProcessesSafety Precautions Design Features ALL ModelsOperation General DescriptionAccessories Maintenance Routine MaintenancePeriodic Maintenance Machine Calibration SpecificationTroubleshooting HOW to USE Troubleshooting GuideContact your local Lincoln Authorized Field Service Facility Troubleshooting PC Board Troubleshooting Guide Firing P.C. Board PC Board Troubleshooting Guide Control P.C. Board MULTI-SOURCE Wiring Diagram DiagramsMULTI-SOURCE Dimension Print Page Page How To Read Shop Drawings Precaucion Warnung