| TROUBLESHOOTING |
| ||
|
| Observe all Safety Guidelines detailed throughout this manual |
| |
|
|
|
|
|
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
Machine output doesn’t stay on. | 1. Cooling air blocked or limited. | |
(Amber Thermal light on, fan run- | 2. Faulty output lead thermostat, | |
ning, digital Output display never |
| SCR heat sink thermostat or |
reads greater than 100) |
| connecting leads. |
| 3. | Ambient cooling air too hot. |
|
| |
Machine output doesn’t stay on. | 1. Faulty cooling fan or wiring. | |
(Amber Thermal light on, fan not | 2. Faulty wiring in shunt circuit. | |
running, digital Output display |
| (Digital Output display reads |
never reads over 100) |
| near zero.) |
| 3. | Faulty Control board. |
| 4. | 115 Vac winding on main trans- |
|
| former not providing voltage. |
| 5. | Fan circuit breaker on front con- |
|
| trol panel is tripped. |
|
| |
Machine will not shut off. | 1. Input contactor (CR1) contacts | |
|
| are frozen. |
| 2. | Defective POWER switch (S1). |
|
|
|
|
|
|
If all recommended possible areas of misadjustment have been checked and the problem persists,
Contact your local Lincoln Authorized Field Service Facility.
CAUTION